RETIRED ›
This product is no longer available and has been replaced by: 034B-L.
034B-LQ Wind Set for RAWS-P Station
利用できるサービス
修理 非対応
キャリブレーション 非対応
フリーサポート 非対応

概要

The 034B-LQ Wind Set, manufactured by Met One, combines a 3-cup anemometer and vane into a single integrated package. The 034B is constructed of lightweight aluminum and is designed for continuous long-term operation.

続きを読む

イメージ

詳細

For this version of the 034B Wind Set, the cable terminates in a military style connector and has a user-specified lead length. The connector attaches to the RAWS-P enclosure, which mounts to a CM6/CM10 tripod, CM110-series tripod, or UT-series tower.

The 034B Wind Set combines a 3-cup anemometer and vane into a single integrated package. The 034B is constructed of lightweight aluminum and is designed for continuous long-term operation.

仕様

Operating Temperature -30° to +70°C
Weight 907 g (2 lb)

Wind Speed (Anemometer)

Range 0 to 75 m/s (0 to 167 mph)
Accuracy < 10.14 m/s (22.7 mph) 0.1 m/s (0.25 mph)
Accuracy > 10.14 m/s (22.7 mph) ±1.1% of true Wind Direction (Vane)
Resolution (0.7998 m s-1)/(scan rate in seconds) or (1.789 mph)/(scan rate in seconds)
Starting Threshold 0.4 m/s (0.9 mph)
Sensor Output Pulsed contact closure
Anemometer Radius 10.7 cm (4.2 in.)
Anemometer Height 24.4 cm (9.6 in.)

Wind Direction (Vane)

Mechanical Range 360°
Electrical Range 356° (4° open)
Accuracy ±4°
Damping Ratio 0.25
Resolution < 5°
Potentiometer Resistance 0 to 10 kΩ (open at crossover)
Vane Length 11.4 cm (4.5 in.)

互換性

The connector attaches to the RAWS-P Permanently Mounted Station, which has an on-board CR1000.

ドキュメント


よくある質問

034B-LQに関するよくある質問の数: 5

すべて展開すべて折りたたむ

  1. The information included on a calibration sheet differs with each sensor. For some sensors, the sheet contains coefficients necessary to program a data logger. For other sensors, the calibration sheet is a pass/fail report.

  2. すべてのセンサに異なるケーブル終端オプションがあるわけではありません。特定のセンサで利用可能なオプションは、センサ製品ページの注文情報エリアの 2 つの場所で確認できます。

    モデル番号
    ケーブル終端オプション リスト
    センサが –ET、–ETM、–LC、–LQ、または –QD バージョンで提供されている場合、そのオプションが利用可能かどうかはセンサモデル番号に反映されます。たとえば、034B は 034B-ET、034B-ETM、034B-LC、034B-LQ、および 034B-QD として提供されています。

    その他のすべてのケーブル終端オプション (利用可能な場合) は、センサ製品ページの注文情報エリアの「ケーブル終端オプション」の下にリストされています。たとえば、034B-L 風力発電セットは、034B-L 製品ページの注文情報エリアに示されているように、–CWS、–PT、および –PW オプションで提供されています。

    注意: 新しい製品が在庫に追加されると、通常は複数のモデル番号を作成するのではなく、1 つのセンサモデルの下に複数のケーブル終端オプションをリストします。たとえば、HC2S3-L には、HC2S3-LC モデルではなく、CS110 に接続するための –C ケーブル終端オプションがあります。

  3. Most Campbell Scientific sensors are available as an –L, which indicates a user-specified cable length. If a sensor is listed as an –LX model (where “X” is some other character), that sensor’s cable has a user-specified length, but it terminates with a specific connector for a unique system:

    • An –LC model has a user-specified cable length for connection to an ET107, CS110, or retired Metdata1.
    • An –LQ model has a user-specified cable length for connection to a RAWS-P weather station.

    If a sensor does not have an –L or other –LX designation after the main model number, the sensor has a set cable length. The cable length is listed at the end of the Description field in the product’s Ordering information. For example, the 034B-ET model has a description of “Met One Wind Set for ET Station, 67 inch Cable.” Products with a set cable length terminate, as a default, with pigtails.

    If a cable terminates with a special connector for a unique system, the end of the model number designates which system. For example, the 034B-ET model designates the sensor as a 034B for an ET107 system.

    • –ET models terminate with the connector for an ET107 weather station.
    • –ETM models terminate with the connector for an ET107 weather station, but they also include a special system mounting, which is often convenient when purchasing a replacement part.
    • –QD models terminate with the connector for a RAWS-F Quick Deployment Station.
    • –PW models terminate with the connector for a PWENC or pre-wired system.
  4. This depends on the information contained in the calibration sheet:

    • If the calibration sheet contains coefficient information, Campbell Scientific keeps a copy, and a replacement copy can be requested.
    • If the calibration sheet does not contain coefficients, Campbell Scientific does not keep a copy. It may be possible to contact the original manufacturer for a replacement copy.
  5. Many Campbell Scientific sensors are available with different cable termination options. These options include the following:

    • The –PT (–PT w/Tinned Wires) option is the default option and does not display on the product line as the other options do. The cable terminates in pigtails that connect directly to a data logger.
    • In the –C (–C w/ET/CS110 Connector) option, the cable terminates in a connector that attaches to a CS110 Electric Field Meter or an ET-series weather station.
    • In the –CWS (–CWS w/CWS900 Connector) option, the cable terminates in a connector that attaches to a CWS900-series interface. Connection to a CWS900-series interface allows the sensor to be used in a wireless sensor network.
    • In the –PW (–PW w/Pre-Wire Connector) option, the cable terminates in a connector that attaches to a prewired enclosure.
    • In the –RQ (–RQ w/RAWS Connector) option, the cable terminates in a connector that attaches to a RAWS-P Permanent Remote Automated Weather Station.

    Note: The availability of cable termination options varies by sensor. For example, sensors may have none, two, or several options to choose from. If a desired option is not listed for a specific sensor, contact Campbell Scientific for assistance.

Privacy Policy Update

We've updated our privacy policy.  詳細はこちら

Cookie Consent

Update your cookie preferences.  クッキーの設定を更新する