RETIRED ›
This product is no longer available and has been replaced by: CR1000.
CR10 Measurement and Control System
利用できるサービス
修理 非対応
キャリブレーション 対応
フリーサポート 非対応

概要

The CR10 was a predecessor of the CR10X. The CR10X was eventually replaced with the CR1000.  The CR10 consisted of a CR10M Measurement and Control Module and a CR10WP Wiring Panel.

続きを読む

利点と特徴

  • Manufactured from 1987-1996
  • Array-based data format
  • Repairs still available

イメージ

詳細

The CR10 had 12 single-ended (six differential) analog input channels, three switched excitation outputs, eight input/output control ports, two pulse counting channels, and a serial I/O port. It provided sensor measurement, timekeeping, data reduction, data/program storage and control functions. Up to 29,908 data points were stored in it's internal memory.

CR10s manufactured after 1 December 1993 (SN>19273) contained an internal jumper that supported use of 2 or 4 kbytes program memory (appropriate PROM also required).

仕様

-NOTE- Note: Additional specifications are listed in the CR10 Specifications Sheet.
Analog Input Channels 12 single-ended (six differential)
Switched Excitation Outputs 3
Input/Output Control Ports 8
Pulse Count Channels 2
Serial I/O Port 1
Memory Stores up to 29,908 data points in internal memory.

互換性

A typical field-based CR10 system consisted of:

  • CR10 with OS10 Operating System
  • Alkaline or Rechargeable Power Supply
  • Weatherproof Enclosure (CR10s ordered with an environmental enclosure were mounted on the enclosure backplate at the factory)

CR10 peripherals such as the CR10KD and CR10TCR, as well as sensors and data retrieval peripherals, were added to complete the system.


よくある質問

CR10に関するよくある質問の数: 1

  1. A practical maximum is to connect one multiplexer per every two control terminals on the data logger. Control terminals can be shared between multiplexers to increase the number of connected multiplexers. Sharing terminals, however, requires more complex wiring and programming. Users who would like to connect more than one multiplexer per every two control terminals are advised to contact a sales or support engineer at Campbell Scientific for assistance.

ケーススタディ

Utah: Irrigation Network Monitoring
In an era when water is becoming a precious resource, the Emery Water Conservancy District......続きを読む
England: Underground Excavation for Rail System
More than 50 CR10-based monitoring systems were used for structural monitoring during the construction of......続きを読む
China: Monitoring the Impact of Visitors
Dunhuang (population 100,000) is on the southwestern edge of the Gobi Desert and is situated......続きを読む
Idaho: Slope Stability Monitoring
The Problem--> Our customer required a data acquisition and control system to monitor a slowly moving......続きを読む
Washington: Weather and Water Quality Station
The Poulsbo Marine Science Center is a non-profit educational facility located on Liberty Bay on......続きを読む
North Wales: Bridge Load Monitoring
Following an inspection a decade ago, the Welsh Office was advised to reduce the allowable......続きを読む
Space Research: Joint Damping Experiment
The Space Shuttle Endeavor carried the CR10 and CR9000 dataloggers into orbit as part of......続きを読む
Argentina: SCADA System for Agricultural Regions
In a country as large as Argentina, monitoring growing conditions in different agricultural regions is......続きを読む