CS610-L 3-Rod TDR Probe with RG8 Cable
Typical Soils
Up to 25 m cable length
気象 applications 水 applications エネルギー applications ガスフラックスと乱流 applications インフラ applications 土壌 applications

概要

The CS610 is used in TDR100- and TDR200-based systems, and it is recommended for typical soils (soil bulk conductivity ≤1.5 dS/m). Its RG8 cable allows the CS610 to have cable lengths longer than 15 m. The maximum distance allowed between the reflectometer and probe tip is 25 m as measured from the tips of the probe's rods to the reflectometer. This probe consists of three pointed, large-diameter rods and a large epoxy head allowing installation in rugged environments.

続きを読む

イメージ

詳細

The CS610 acts as a wave guide. Impedance along the rods varies with the dielectric permittivity of the surrounding soil. Because the dielectric permittivity of soil primarily depends on the amount of water present, soil volumetric water content can be inferred from the reflected measurements. Soil bulk electrical conductivity is determined from the attenuation of the applied pulse.

Campbell Scientific offers six TDR probes for our TDR100- and TDR200-based systems. The probes have different rods and connector cables allowing them to be used in different soil types and with different cable lengths. Other TDR probes offered by Campbell Scientific inclde the CS605, CS630, CS635, CS640, and CS645.

仕様

Maximum Soil Bulk Electrical Conductivity ≤ 1.4 dS/m
Spacing between Outer Rods 4.5 cm (1.77 in.)
Rod Diameter 0.48 cm (0.187 in.)
Rod Length 30 cm (12 in.)
Epoxy Head Dimensions 7 x 10.8 x 1.9 cm (2.8 x 4.3 x 0.7 in.)
Weight 363 g (13 oz) without cable
Cable Weight 272 g (10 oz) per 3.1 m (10 ft) of cable

互換性

注意: 以下は代表的な互換性情報を示しています。互換性のある製品や互換性のない製品をすべて網羅したリストではありません。

Measurement and Control

製品 互換性 注意
SDMX50 (リタイア)
SDMX50LP (リタイア)
SDMX50SP (リタイア)
TDR100 (リタイア)
TDR200

よくある質問

CS610-Lに関するよくある質問の数: 1

  1. In applications where TDR probes are used to measure soil water content, the maximum distance from the TDR probe back to the TDR100/TDR200 (even through one or more multiplexers) cannot exceed 15 m (50 ft) when using RG58 coaxial cable; the CS605-L, CS630-L, and CS640-L TDR probes have an RG58 cable. When using low-loss coaxial cable, the distance cannot exceed ≈25 m (80 ft); the CS610-L, CS635-L, and CS645-L TDR probes have a low-loss coaxial cable.

    In slope stability and rock mass deformation applications, the maximum coaxial cable length should not exceed ≈1 mile (5,280 ft). The maximum combined length of all SDM cables in the system should not exceed ≈76 m (250 ft).


以下に記載

下記製品のその他アクセサリです:
下記の製品は置き換えられました

Privacy Policy Update

We've updated our privacy policy.  詳細はこちら

Cookie Consent