利用できるサービス | |
---|---|
修理 | 対応 |
キャリブレーション | 非対応 |
フリーサポート | 対応 |
The CS215 is a temperature and relative humidity probe that uses a Swiss-made digital humidity and temperature element that makes accurate and stable measurements. The element is based on Sensirion's CMOSens technology, which has been tested for more than two years in alpine conditions. The CS215 outputs an SDI-12 signal that is measurable by most Campbell Scientific data loggers.
続きを読むThe CS215 uses the Sensirion SHT75, a combined relative humidity and temperature element, to provide accurate, stable measurements. The Sensirion SHT75 element is field-replaceable, eliminating the downtime typically required for the recalibration process. The CS215 outputs an SDI-12 signal that's measurable by many Campbell Scientific data loggers.
The CS215 should be housed in a solar radiation shield—typically the 41303-5A. The 41303-5A 6-plate naturally aspirated shield attaches to a mast, crossarm, or tower leg.
Sensing Element | Sensirion SHT75 |
Measurement Description | Temperature, relative humidity |
Signal Type/Output | SDI-12 |
Communication Standard | SDI-12 V1.3 (responds to a subset of commands) |
Housing Material | Anodized aluminum |
Housing Classification | IP65 (NEMA 4) |
Sensor Protection | Outer glass-filled polypropylene cap. Inner expanded PTFE filter. Filter material has a porosity of 64% and a pore size of < 3μm. |
Supply Voltage |
|
Typical Current Drain |
|
EMC Compliance | Tested and conforms to IEC61326:2002. |
Operating Temperature Range | -40° to +70°C |
Field Replaceable Chip or Recalibrate | Field-replaceable chip |
Diameter |
|
Length | 18.0 cm (7.1 in.) including strain relief |
Weight | 150 g (5.3 oz) with 3.05 m (10 ft) cable |
Relative Humidity |
|
Measurement Range | 0 to 100% RH (-20° to +60°C) |
Output Resolution | 0.03% RH |
Accuracy |
|
Short-Term Hysteresis | < 1% RH |
Temperature Dependence | Better than ±2% (-20° to +60°C) |
Typical Stability | ±1.0% per year |
Response Time with Filter | < 20 s (63% response time in still air) |
Calibration Traceability | NIST and NPL standards |
Air Temperature |
|
Measurement Range | -40° to +70°C |
Output Resolution | 0.01°C |
Accuracy |
|
Response Time with Filter | < 120 s (63% response time in air moving at 1 m s-1) |
注意: 以下は代表的な互換性情報を示しています。互換性のある製品や互換性のない製品をすべて網羅したリストではありません。
製品 | 互換性 | 注意 |
---|---|---|
21X (リタイア) | ||
CR10 (リタイア) | ||
CR1000 (リタイア) | ||
CR1000X (リタイア) | ||
CR10X (リタイア) | ||
CR200X (リタイア) | ||
CR206X (リタイア) | ||
CR211X (リタイア) | ||
CR216X (リタイア) | ||
CR23X (リタイア) | ||
CR295X (リタイア) | ||
CR300 (リタイア) | ||
CR3000 (リタイア) | ||
CR310 | ||
CR500 (リタイア) | ||
CR5000 (リタイア) | ||
CR510 (リタイア) | ||
CR6 | ||
CR800 (リタイア) | ||
CR850 (リタイア) | ||
CR9000 (リタイア) | ||
CR9000X (リタイア) |
When exposed to sunlight, the CS215 must be housed in a 41303-5A radiation shield. To attach the 41303-5A to a CM202, CM204, or CM206 crossarm, place the 41303-5A’s U-bolt in the bottom holes. To attach the radiation shield directly to a tripod mast, tower mast, or tower leg, place the U-bolt in the side holes.
The CS215-L Temperature and RH sensor can also be housed in the 43502 if a special adapter from R. M. Young (R. M. Young pn 43537) is used.
CS215-Lに関するよくある質問の数: 13
すべて展開すべて折りたたむ
Relative humidity (RH) from the probe is capped at 100%. If readings of 100% occur during drier conditions, it is possible that the chip, the entire sensor, or both have associated issues. Repair, maintenance, or replacement is likely needed. Contact Campbell Scientific for assistance.
Yes. This is pn 18142.
If the values are not within the published range of the sensor, there are several things to check:
Yes, using pn 18144, Replacement RH and Temperature Element and Filter Cap for CS215. However, Campbell Scientific recommends taking the necessary precautions associated with changing electronics in the field. As this is a relatively small chip, it is not recommended to replace the chip during stormy weather or without having some type of collection container placed underneath in case the chip is accidentally dropped.
For assistance replacing the chip, refer to the “Maintenance and Calibration” section of the instruction manual.
Yes. This can be purchased from Campbell Scientific (pn 18144, Replacement RH and Temperature Element and Filter Cap for CS215). This chip replaces both the temperature and RH humidity sensing element.
No. The sensor cannot be calibrated, but Campbell Scientific can perform a calibration verification that includes multiple points (temperature and relative humidity). Campbell Scientific recommends using three points for RH (10%, 50%, and 90%) at one temperature (25 degrees Celsius), as well as an additional temperature point. This verification process has an initial setup charge and an additional per-point charge. Campbell Scientific sends a document indicating the values tested to with the accompanying measurement from the associated sensor.
Refer to the “Maintenance and Calibration” section of the instruction manual.
The most significant difference is that the CS215-L has an SDI-12 output and that the HMP60-L has a voltage output. Additional differences are outlined in the “Air Temperature & Relative Humidity” brochure, which compares all of the Campbell Scientific temperature and relative humidity sensors.
すべてのセンサに異なるケーブル終端オプションがあるわけではありません。特定のセンサで利用可能なオプションは、センサ製品ページの注文情報エリアの 2 つの場所で確認できます。
モデル番号
ケーブル終端オプション リスト
センサが –ET、–ETM、–LC、–LQ、または –QD バージョンで提供されている場合、そのオプションが利用可能かどうかはセンサモデル番号に反映されます。たとえば、034B は 034B-ET、034B-ETM、034B-LC、034B-LQ、および 034B-QD として提供されています。
その他のすべてのケーブル終端オプション (利用可能な場合) は、センサ製品ページの注文情報エリアの「ケーブル終端オプション」の下にリストされています。たとえば、034B-L 風力発電セットは、034B-L 製品ページの注文情報エリアに示されているように、–CWS、–PT、および –PW オプションで提供されています。
注意: 新しい製品が在庫に追加されると、通常は複数のモデル番号を作成するのではなく、1 つのセンサモデルの下に複数のケーブル終端オプションをリストします。たとえば、HC2S3-L には、HC2S3-LC モデルではなく、CS110 に接続するための –C ケーブル終端オプションがあります。
Most Campbell Scientific sensors are available as an –L, which indicates a user-specified cable length. If a sensor is listed as an –LX model (where “X” is some other character), that sensor’s cable has a user-specified length, but it terminates with a specific connector for a unique system:
If a sensor does not have an –L or other –LX designation after the main model number, the sensor has a set cable length. The cable length is listed at the end of the Description field in the product’s Ordering information. For example, the 034B-ET model has a description of “Met One Wind Set for ET Station, 67 inch Cable.” Products with a set cable length terminate, as a default, with pigtails.
If a cable terminates with a special connector for a unique system, the end of the model number designates which system. For example, the 034B-ET model designates the sensor as a 034B for an ET107 system.
We've updated our privacy policy. 詳細はこちら
Update your cookie preferences. クッキーの設定を更新する