RETIRED ›
This product is no longer available.
TGA200A Trace Gas Analyzer
利用できるサービス
修理 対応
キャリブレーション 非対応
フリーサポート 対応


Stay tuned in the coming year for our exciting new product offerings in trace gas measurements!

概要

The TGA200A Trace Gas Analyzer measures trace gas concentrations in an air sample using tunable-diode laser absorption spectroscopy (TDLAS). This technique provides high sensitivity, speed, and selectivity. Its simple design allows it to measure one of many gases by choosing an appropriate laser source. The TGA200A features a 1.5 m single-pass optical measurement system that uses a thermoelectrically cooled laser. 

The TGA200A is housed in a rugged environmental enclosure designed for use in demanding climates ranging from high-latitude boreal forests, permafrost, and tundra to agriculturally intensive mid-latitude regions and equatorial rainforests. Common applications include slow-gradient or high-speed eddy-covariance measurements of nitrous oxide fluxes or carbon fluxes in the form of methane, or isotopologs of carbon dioxide in all global ecosystems.

Campbell Scientific has been manufacturing TGAs since 1993, and the TGA200A is the result of over 20 years of research and development. Even though previous generations of the TGA (TGA100, TGA100A, and TGA200) have the same core technology, the TGA200A builds upon this succession with further improvements. For more information about the TGA200A, contact Campbell Scientific, Inc.

利点と特徴

  • Small sample cell volume that provides superior frequency response
  • Thermoelectrically cooled laser; no cryogenic cooling required
  • Laser upgrades available to existing TGA customers; contact Campbell Scientific for more information
  • Choice of laser sources to measure CO2 isotopes, N2O, or CH4
  • Optically simple measurement system that does not require cleaning of the optical cell in the field
  • 500 Hz measurement rate that supports excellent synchronization
  • Rugged environmental enclosure that allows the TGA200A to be placed outside on the ground
  • Simple Windows user interface for setup, configuration, and real-time monitoring
  • Complete greenhouse gas measurement flux solution provided by combining one or more TGA200As with Campbell Scientific’s sonic anemometers, data loggers, gas analyzers, closed-path gas analyzers, or eddy-covariance system
  • Advanced sampling systems also available for low-flow applications such as profile, gradient, or user-supplied chamber measurements

イメージ

TGA200A side view
TGA200A side view
TGA200A side view
TGA200A side view (top of enclosure sitting behind)
TGA200A side view (top of enclosure removed)
TGA200A top view
TGA200A laser end of the optical bench
TGA200A detector end of the optical bench
TGA200A electronics box
TGA200A side view (feedthrough cover opened)
TGA200A feedthrough bracket and plumbing connections
TGA200A side view (with pn 16599 installed)

仕様

Measurement Rate 500 Hz
Sample Cell Volume 200 mL
Dimensions 211 x 47 x 55 cm (83 x 18.5 x 21.5 in.)
Weight
  • 5.4 kg (12.0 lb) for power module with cable
  • 62.8 kg (138.5 lb) for TGA200A

Typical Measurement Noise

-NOTE- Preliminary Results

Allan deviation with 100 ms averaging time.
Nitrous Oxide (N2O) - Laser pn 30478 1.5 nmol mol-1
Methane (CH4) - Laser pn 30477 7.0 nmol mol-1
Nitrous Oxide (N2O) - Laser pn 31121 1.8 nmol mol-1
Carbon Dioxide (CO2) - Laser pn 31121 0.3 μmol mol-1 (based on the 13C16O16O isotopolog)
Carbon Dioxide (CO2) - Laser pn 31119 0.15 μmol mol-1
δ13C - Laser pn 31119 0.5 ‰
Carbon Dioxide (CO2) - Laser pn 30877 0.5 μmol mol-1
δ13C - Laser pn 30877 2.0 ‰
δ18O - Laser pn 30877 2.0 ‰

Power Requirements

Analyzer (TE-cooled laser) 90 to 264 Vac, 47 to 63 Hz, 34 W (max) 22 W (typical)
Heater 90 to 264 Vac, 47 to 63 Hz, 150 W (max) 50 W (typical)

互換性

注意: 以下は代表的な互換性情報を示しています。互換性のある製品や互換性のない製品をすべて網羅したリストではありません。

Data Loggers

製品 互換性 注意
CR3000 (リタイア)
CR5000 (リタイア)
CR6

互換性に関する追加情報

Data Logger Considerations

Data is collected from the TGA200A using a Campbell Scientific data logger. The TGA200A is compatible with data loggers that support SDM communications. In many cases, a sampling system containing a data logger is ordered with the TGA200A. Contact Campbell Scientific for more details about sampling systems and compatibility with user-supplied components, such as leaf chambers.

ダウンロード

TGA200A Firmware v.1.1 (1.1 MB) 02-12-2015

The TGA200A firmware is used to support the TGA200A or prior TGA models that have been upgraded to use a thermoelectrically cooled (TEC) laser.

The TGA firmware includes the OS that must be uploaded to the analyzer's CPU board before operating a TEC laser.

Warning: Download of TGA200A Firmware should only be done for use with TGA models running TEC lasers!

TGA TEC v.1.1 (10.6 MB) 02-12-2015

The TGA TEC Support Software is used to support the TGA200A or prior TGA models that have been upgraded to use a thermoelectrically cooled (TEC) laser.

TGA TEC is a user-interface software package that allows users to connect to the analyzer, set settings, and monitor real-time analyzer performance.

Compatibility: 
TGA TEC 1.1 is compatible with the Windows 7 operating system or newer.

Warning: Download of TGA TEC v1.1 should only be done for use with TGA models running TEC lasers!

記事とプレスリリース

ニュースレター記事


下記の製品は置き換えられました

Privacy Policy Update

We've updated our privacy policy.  詳細はこちら

Cookie Consent

Update your cookie preferences.  クッキーの設定を更新する