Campbell Scientific ブログ 役立つハウツー情報と専門家のアドバイス

ブログについて

The Campbell Scientific Blog has relevant information that expands your knowledge, answers your questions, and helps overcome your measurement challenges.


ブログを検索する


ブログを購読する

興味のある分野に一致する新しいブログ記事が投稿されたときに電子メール通知を受信するように設定してください。


Area / Application

Product Category

Activity

Corporate / News

Enter your email address:



記事を提案する

もっと詳しく知りたいトピックはありますか? お知らせください。できるだけ具体的にご記入ください。

Leave this field empty

Displaying 101 - 120 of 170 articles

Minimize Losses from Frost Using Direct Measurements

著者: Dirk Baker | 最終更新日: 02/08/2017 | コメント: 0

minimize losses from frost using direct measurements

Are you concerned about frost damage to your crops? There are a number of high-value crops that are critically vulnerable to frost damage. Especially on buds, flowers, and early fruit, frost can cost growers thousands of dollars per acre. For a long time, many growers have monitored... 続きを読む

Sending Email from Your Data Logger Just Got Easier!

著者: Dana Worley | 最終更新日: 01/25/2017 | コメント: 19

sending email from your data logger just got easier!

Have you had problems finding an SMTP server to use to send emails from your data logger? Are compatibility issues causing you to look for a work-around? Keep reading for a solution that may be just what you need. Some Background In 2006, we added the ability... 続きを読む

Exciting Possibilities for CR310 Users

著者: Robin Deissinger | 最終更新日: 01/11/2017 | コメント: 0

exciting possibilities for cr310 users

In this short interview, Sam Utley, the product manager for the new CR310, tells us about the enhanced functionality this data logger provides and why he feels the CR310 offers exciting possibilities for our customers. Sam is a member of the Product Management (PM) team... 続きを読む

The Most Rugged Air Temp/RH Sensor We Know of: the EE181

著者: Robin Deissinger | 最終更新日: 12/14/2016 | コメント: 0

the most rugged air temp/rh sensor we know of: the ee181

In this interview, Chod Stephens, the product manager for the new EE181-L, tells us why this new sensor is ideal for Campbell Scientific customers with deployment sites in extreme environments. Chod is the Technical Product Manager for the Environmental Group at Campbell Scientific, Inc. He... 続きを読む

Available Security Measures for Internet-Connected Data Loggers

著者: Dana Worley | 最終更新日: 12/07/2016 | コメント: 2

available security measures for internet-connected data loggers

The Internet of Things offers a lot of advantages in today’s culture. There are consumer devices that let you monitor and control mood lighting and music in your home, keep track of last week’s leftover dinner in your refrigerator, and help you brew a cup... 続きを読む

How to Replace “Undefined” or “N/A” with Your Real-Time Data Values

著者: Janet Albers | 最終更新日: 11/30/2016 | コメント: 0

how to replace “undefined” or “n/a” with your real-time data values

If you use Campbell Scientific data logger support software to connect to your data logger, you may monitor your data from within the software. Have there been times when you’ve seen “Undefined” or “N/A” instead of your data values? What does that mean, and how... 続きを読む

How to Prevent a Program Update from Causing a Loss of Communication

著者: Robert Hyatt | 最終更新日: 11/10/2016 | コメント: 5

how to prevent a program update from causing a loss of communication

Imagine that you have a data logger station three hours away that gathers your measurement data. To physically get to your station, not only do you have to drive for three hours, but then you have to hike for an hour up a snow-covered mountain. A... 続きを読む

Sharing Your Monitored Data via Social Media

著者: Barbra Utley | 最終更新日: 10/28/2016 | コメント: 0

sharing your monitored data via social media

Whether you measure and monitor conditions for flooding, road weather, aviation, fire, or avalanches, your data is important to you and those with whom you share it. Oftentimes, sharing your data quickly is critical, as conditions may change rapidly and require prompt action. In this... 続きを読む

The Many Possibilities of PakBus Networking

著者: Jacob Davis | 最終更新日: 10/12/2016 | コメント: 6

the many possibilities of pakbus networking

What do you do if you have two data loggers installed really close to each other and you only want to pay the bill for running one cellular modem? How do you get data from both data loggers using a single modem? How do you... 続きを読む

The Internet of Things (IoT) – Doing Our “Thing” Since Y2K

著者: Dana Worley | 最終更新日: 09/28/2016 | コメント: 2

the internet of things (iot) – doing our “thing” since y2k

We all remember the year 2000 as the year that The World As We Know It would come to an end. Computer systems were predicted to come crashing down on January 1, leaving in their wake failing infrastructure that would affect millions of lives. In... 続きを読む

How to Know when Your Data Logger Memory Is Getting Full

著者: Janet Albers | 最終更新日: 09/15/2016 | コメント: 2

how to know when your data logger memory is getting full

It’s common for our customers to wonder when their data logger memory is going to be full, what will happen to their data when the memory is full, and what they should do about it. After all, your data is specific to your application and... 続きを読む

How to Access Your Measurement Data Using DNP3

著者: Paul Smart | 最終更新日: 09/02/2016 | コメント: 1

how to access your measurement data using dnp3

Turning your Campbell Scientific data logger into a DNP3 outstation is a great way to allow systems that use the DNP3 protocol to have access to your live measurement data, as well as historical data. When you use your data logger as a DNP3 outstation, the... 続きを読む

LoggerNet Admin at Your Service for Mission-Critical Applications

著者: Dana Worley | 最終更新日: 08/05/2016 | コメント: 2

loggernet admin at your service for mission-critical applications

While many of our customers are knowledgeable about our LoggerNet datalogger support software, not as many are familiar with LoggerNet Admin and the benefits it can offer. In this article, I’ll introduce you to LoggerNet Admin, show you how easy it is to install it as... 続きを読む

Line of Sight: More than Meets the Eye

著者: Travis McKissack | 最終更新日: 07/21/2016 | コメント: 0

line of sight: more than meets the eye

When it comes to designing an RF (radio frequency) telemetry link, many people know that you need to ensure that there is an unobstructed line-of-sight (LOS) between the transmitting and receiving antennas. Unfortunately, many people don’t know that there is more to this seemingly obvious... 続きを読む

アプリケーションに最適な土壌水分含有量センサを見つける方法

著者: Jason Ritter | 最終更新日: 07/06/2016 | コメント: 4

アプリケーションに最適な土壌水分含有量センサを見つける方法

土壌水分含有量センサーにはさまざまな種類があるため、用途に最適なものを選択するのは難しく、混乱するかもしれません。選択を支援するには、土壌水分含有量センサーが実際に何を測定するのか、優れた土壌水分含有量センサーの特徴は何か、メーカーの仕様をどのように理解するかを理解することが重要です。この記事では、センサーの選択プロセスに役立つこれらのトピックについて説明します。 土壌水分含有量センサーは実際に何を測定するのでしょうか? 水分を直接測定する市販の土壌水分含有量センサーがないことに驚かれるかもしれません。代わりに、センサーは、水分含有量に関連する他の土壌特性の変化を予測可能な方法で検出します。水分含有量によって変化し、簡単に測定できる一般的な土壌特性には、誘電率、熱伝導率、中性子束密度などがあります。この記事では、誘電率を測定するセンサーに焦点を当てます。 誘電率センサーは、市場で最も一般的なタイプの土壌水分含有量センサーです。これらのセンサーは、次のようなさまざまな技術を使用して周囲の土壌の誘電率を測定します。 Time domain reflectometry Time domain transmissivity Frequency domain reflectometry Time of charge capacitance Transmission line oscillation Coaxial impedance dielectric reflectometry Coaxial differential amplitude reflectometry 技術に関係なく、同じ原理が使われます。土壌のバルク誘電率は体積水分含有量に応じて変化します。 誘電率を最も簡単に考える方法は、蓄えられた電気エネルギーと考えることです。センサーは土壌に電界を生成し、水分子は極性があるため、土壌内の結合していない水分子は電界線に沿って回転します。 結合していない水分子の回転にはエネルギーが必要で、このエネルギーは整列した水分子に位置エネルギーとして蓄えられます。土壌に水分が多いほど、蓄えられるエネルギーも多くなり、土壌の体積誘電率が高くなります。 土壌の他の成分、つまり鉱物や有機固形物、空気も電気エネルギーを蓄えますが、水は土壌の他の部分の 10 倍以上のエネルギーを蓄えることができます。そのため、センサーの測定体積に出入りする水の動きが誘電率の変化に大きく影響します。 土壌水分量センサーは、誘電率、つまり水分量に応じて変化する電気信号を出力するように設計されています。一部のセンサーは誘電率を決定してから水分量に変換しますが、他のセンサーはセンサーの電気出力を 1 回のステップで体積水分量に変換します。どちらの方法を使用する場合でも、土壌の水分は体積誘電率に影響し、それがセンサーの電気出力に影響します。精度仕様を比較するときには、この点を覚えておくことが重要です。 優れた土壌水分含有量センサーとはどのようなものでしょうか? 理想的な高性能土壌水分含有量センサーは、次の特性をすべて備えています。 精度と解像度の要件を満たします。 必要な期間だけ使用できます。 校正は最小限で済み、再校正は必要ありません。 予算の要件を満たします。 設置と測定が簡単です。 ご想像のとおり、これらの特性は互いに競合する可能性があります。たとえば、耐久性があり高精度のセンサーは、耐久性が低く精度が低いセンサーと比較すると高価になる可能性があります。センサーメーカーは、これらの競合する要素の適切なバランスを見つけようとします。アプリケーションに最適なセンサーを決定するには、これらの要素のどれが最も重要かを判断し、最優先事項に最も一致するセンサーを探します。 メーカーの仕様とは何を意味しますか? 土壌水分含有量センサーの仕様を本当に理解するには、水分含有量、誘電率、および誘電率に応じて変化する電気信号の関係について考えると役立ちます。これら 3 つの関係によって、水分含有量値の精度と解像度、およびセンサーの動作範囲が決まります。 正確度 体積水分含有量測定の精度は、いくつかの要素に依存します。 電気測定の精度 測定電子機器に対する温度の影響 水の誘電率と土壌の電気伝導率に対する温度の影響 異なる誘電率の値を推定するセンサーの精度 電気測定値または誘電率値を体積水分含有量に変換する関数の精度 センサー周囲の土壌が校正関数とどの程度一致するか すべての土壌水分含有量センサーが誘電率の測定精度仕様を提供していれば、さまざまなセンサーの性能を比較するのがはるかに簡単になります。残念ながら、多くのユーザーは誘電率と体積水分含有量の関係、および最終的な水分含有量の推定値に誤差を加える可能性のあるさまざまな条件を完全に理解していません。 すべての土壌に機能する単一の校正機能はないため、メーカーは通常、1 つまたはいくつかの「代表的な」土壌を選択し、その選択に基づいて水分含有量の精度仕様を提供します。では、たとえば、「±1% 体積水分含有量」などの精度仕様は実際には何を意味するのでしょうか。この仕様は、校正作業が行われた条件下での ±1% を意味します。これらの条件は、おそらく屋内で、温度変化が最小限で、代表的な土壌タイプが 1 つまたは数種類しかない場合です。 ご使用の環境が同じ条件である場合、センサーの精度は仕様を満たします。 センサーを自然環境(変動がはるかに大きい)に設置する場合、独自のキャリブレーションを実行しない限り、精度が仕様を満たさない可能性があります。 もう 1 つの重要な考慮事項は、土壌が非常に乾燥すると、誘電土壌水分含有量センサーの精度が低下することです。土壌内の水分量が非常に少ない場合、土壌全体の体積誘電率に対する水分の寄与は小さくなり、センサーの変化検出能力を下回る場合があります。乾燥した土壌では、水分含有量の変化よりも温度がセンサー出力に大きく影響することがよくあります。 ヒント: 低水分含有量レベルで高い精度を保証する仕様には十分注意してください。 注意: 精度は絶対精度 (水分率/乾燥土壌率) または読み取り値のパーセンテージとして指定できます。読み取り値のパーセンテージを絶対精度に変換するには、動作範囲の上限と下限を掛けます。... 続きを読む

How to Store Data Logger Data to a Memory Card

著者: Carolyn Ivans | 最終更新日: 06/22/2016 | コメント: 7

how to store data logger data to a memory card

You may have identified the need to add external data storage to your data logger with flash-memory cards. But do you know which CRBasic instruction to use to do it? In this article, I’ll help you choose the most suitable instruction for your application. In a... 続きを読む

The Best Way to Edit Input Locations in Edlog Programs

著者: Janet Albers | 最終更新日: 06/08/2016 | コメント: 0

the best way to edit input locations in edlog programs

If you have one of our retired data loggers that uses the Edlog programming language, do you know the best way to change an Input Location name? It’s possible that you may want to use a different name or insert a name where one is... 続きを読む

6 Tips to Protect Your Weather Station from Birds

著者: Robin Deissinger | 最終更新日: 05/25/2016 | コメント: 0

6 tips to protect your weather station from birds

You’ve got your weather station set up and running, your data is coming across just fine, and then a bird decides your station is a wonderful place to make a home. That’s great for the bird, but not so great for the performance of your... 続きを読む

Get to Know Your Data Logger’s Spare Tire: The Lithium Battery

著者: Jacob Davis | 最終更新日: 05/18/2016 | コメント: 2

get to know your data logger’s spare tire: the lithium battery

When was the last time you checked the air pressure on your automobile’s spare tire? What if you were driving along, got a flat tire, and discovered that your spare tire was flat as well? We don’t often think about our spare tire until we... 続きを読む

Why Measurements on the Edge Require Careful Planning

著者: Shaun Dustin | 最終更新日: 05/11/2016 | コメント: 1

why measurements on the edge require careful planning

I have worked with Boy Scouts for the past 18 years. When I need to talk to boys about taking risks, I share a story about three young men who were competing for a job to deliver goods over a mountain pass with hairpin turns... 続きを読む

私たちはソーシャルメディアで積極的に活動しています!
以下のプラットフォームでフォローして、最新情報を入手してください。