利用できるサービス |
---|
The CMP6, manufactured by Kipp & Zonen, is an ISO first-class pyranometer that monitors solar radiation for the full solar spectrum range. It connects directly to a Campbell Scientific data logger and is commonly used for environmental monitoring, solar resource assessment, and solar power performance applications.
続きを読むThe CMP6 measures solar radiation with a high-quality blackened thermopile protected by two glass domes. Its flat spectral sensitivity, from 285 to 2800 nm, makes it ideal for applications in natural sunlight, under plant canopies, in green houses or buildings, and inverted to measure reflected solar radiation.
A desiccant-filled drying cartridge prevents dew from forming on the inner sides of the CMP6's domes. Campbell Scientific also offers the CVF4 heater/ventilator that keeps its domes free from ice and dew.
The CMP6 includes a white snap-on sun shield that reduces the sensor's temperature. A bubble level and adjusting leveling screws enable the sensor to be leveled without using a leveling base.
The CMP6 produces a millivolt signal that is measured directly by a Campbell Scientific data logger.
Sensor | High-quality blackened thermopile protected by two glass domes |
Measurement Description | Monitors solar radiation for the full solar spectrum range |
ISO Classification | Class B (first class) |
Spectral Range | 285 to 2800 nm |
Sensitivity | 5 to 20 μV W-1 m2 |
Temperature Dependence of Sensitivity | < 4% (-10° to +40°C) |
Response Time | < 18 s (95% of final value) |
Zero Offset Due to Thermal Radiation | < 15 W/m2 (200 W/m2) |
Non-Stability | < 1% (change/year) |
Non-Linearity | < 1% (0 to 1000 W/m2) |
Directional Error | < 20 W/m2 (up to 80° with 1000 W/m2 beam) |
Tilt Error | < 1% |
Level Accuracy | 0.1° |
Impedance | 20 to 200 Ω |
Operating Temperature Range | -40° to +80°C |
Typical Signal Output | 0 to 20 mV (for atmospheric applications) |
Maximum Irradiance | 2000 W/m2 |
Expected Daily Uncertainty | < 5% |
Dome Diameter | 5 cm (2 in.) |
Width | 15 cm (5.9 in.) with shield |
Height | 9.25 cm (3.64 in.) |
Weight | 0.9 kg (2 lb) with 10.1 m (33 ft) cable |
注意: 以下は代表的な互換性情報を示しています。互換性のある製品や互換性のない製品をすべて網羅したリストではありません。
製品 | 互換性 | 注意 |
---|---|---|
CR1000 (リタイア) | ||
CR1000X (リタイア) | ||
CR300 (リタイア) | ||
CR3000 (リタイア) | ||
CR310 | ||
CR350 | ||
CR6 | ||
CR800 (リタイア) | ||
CR850 (リタイア) |
The CMP6 has a bubble level and two leveling feet, which allow it to be leveled without using a leveling base. This pyranometer mounts to a mast, crossarm, or pole (1.0 in. to 2.1 in. OD) via the CM255 or CM255LS mounting stand. The CMP6 should be mounted away from all obstructions and reflective surfaces that might adversely effect the measurement.
CMP6-Lに関するよくある質問の数: 10
すべて展開すべて折りたたむ
No. These are all passive devices that create their own voltage signal as a response to the measurement being made. There is, however, a heater and ventilator for these sensors (CVF4-L) that requires a power supply.
A cable length of 300 ft can be used with the understanding that additional noise may be introduced into the measurement. Typically, in systems with pyranometers, the sensors are installed near the data logger (within 50 ft). If an application requires long leads, contact Campbell Scientific for assistance.
すべてのセンサに異なるケーブル終端オプションがあるわけではありません。特定のセンサで利用可能なオプションは、センサ製品ページの注文情報エリアの 2 つの場所で確認できます。
モデル番号
ケーブル終端オプション リスト
センサが –ET、–ETM、–LC、–LQ、または –QD バージョンで提供されている場合、そのオプションが利用可能かどうかはセンサモデル番号に反映されます。たとえば、034B は 034B-ET、034B-ETM、034B-LC、034B-LQ、および 034B-QD として提供されています。
その他のすべてのケーブル終端オプション (利用可能な場合) は、センサ製品ページの注文情報エリアの「ケーブル終端オプション」の下にリストされています。たとえば、034B-L 風力発電セットは、034B-L 製品ページの注文情報エリアに示されているように、–CWS、–PT、および –PW オプションで提供されています。
注意: 新しい製品が在庫に追加されると、通常は複数のモデル番号を作成するのではなく、1 つのセンサモデルの下に複数のケーブル終端オプションをリストします。たとえば、HC2S3-L には、HC2S3-LC モデルではなく、CS110 に接続するための –C ケーブル終端オプションがあります。
Most Campbell Scientific sensors are available as an –L, which indicates a user-specified cable length. If a sensor is listed as an –LX model (where “X” is some other character), that sensor’s cable has a user-specified length, but it terminates with a specific connector for a unique system:
If a sensor does not have an –L or other –LX designation after the main model number, the sensor has a set cable length. The cable length is listed at the end of the Description field in the product’s Ordering information. For example, the 034B-ET model has a description of “Met One Wind Set for ET Station, 67 inch Cable.” Products with a set cable length terminate, as a default, with pigtails.
If a cable terminates with a special connector for a unique system, the end of the model number designates which system. For example, the 034B-ET model designates the sensor as a 034B for an ET107 system.
The ISO and WMO classify First Class pyranometers, such as the CMP6-L, as suitable for network operations. However, if accuracy is of paramount concern, consider using Class A pyranometers, such as the CMP11-L and CMP21-L, instead.
Yes. Each pyranometer is shipped with an instruction manual provided by Kipp & Zonen that contains information concerning its construction, spectral sensitivity, cosine response, and a simple sensor check out procedure. Included with the sensor and manual is a calibration certificate with the sensor sensitivity value and serial number.
Many Campbell Scientific sensors are available with different cable termination options. These options include the following:
Note: The availability of cable termination options varies by sensor. For example, sensors may have none, two, or several options to choose from. If a desired option is not listed for a specific sensor, contact Campbell Scientific for assistance.
Because of the loss of IR radiation, nearly all thermopile instruments typically have a negative offset. This offset is most easily visible at night-time, when a small negative value is read instead of zero. This same offset is present during the daytime, but it is not as visible because of the large solar signal.
Another common issue involves leveling an instrument. Leveling a thermopile instrument can cause errors in the direct beam component because the cosine response is not correct. These errors are more notable when the sun is close to the horizon because the angle is so shallow.
All of these pyranometers measure the amount of solar short-wave radiation incident on a surface. Because of their accuracy and performance level, the CMP11-L and CMP21-L are classified by the International Organization for Standardization (ISO) and World Meteorological Organization (WMO) as Secondary Standard sensors, representing the highest level of measurements made by pyranometers. In comparison, the CMP6-L is classified as a First Class sensor, which is the middle classification for pyranometers. (Second Class is the lowest pyranometer classification.)
To incorporate a sensor that is compatible with wireless sensor interfaces into a wireless network, a CWS900-series wireless sensor interface is needed, as well as an A205 CWS-to-PC interface to configure it.