Used with our RF300-series radios, the RF95A provides an RF communication interface between the data logger and an RF300-series radio.
続きを読むNote: The RF95A has been replaced by the RF500M modem. The RF95A remains available for customers with application-specific custom PROMS.
The RF95A is used with our RF300-series radios. It provides an RF communication interface between the data logger and a RF300-series radio. Each RF95A contains dip switches that allow the user to address the modem with a number between 0 and 255.
The RF95A and the primary transceivers it supported, the RF300-series radios, were replaced on our standard price lists by the RF310-series radios and RF310M modem in June 2002.
Standard Operating Temperature Range | -25° to +50°C |
Extended Operating Temperature Range | -55° to +85°C |
Dimensions |
|
Weight | 227 g (8 oz) |
注意: 以下は代表的な互換性情報を示しています。互換性のある製品や互換性のない製品をすべて網羅したリストではありません。
製品 | 互換性 | 注意 |
---|---|---|
21X (リタイア) | ||
CR10 (リタイア) | ||
CR10X (リタイア) | ||
CR23X (リタイア) | ||
CR500 (リタイア) | ||
CR5000 (リタイア) | ||
CR510 (リタイア) | ||
CR9000 (リタイア) |
製品 | 互換性 | 注意 |
---|---|---|
HT90 UHF (リタイア) | ||
HT90 VHF (リタイア) | ||
P50 UHF (リタイア) | ||
P50 VHF (リタイア) | ||
RF100 (リタイア) | ||
RF200 (リタイア) | ||
RF232A (リタイア) | ||
RF300 (リタイア) | ||
RF301 (リタイア) | ||
RF302 (リタイア) | ||
RF303 (リタイア) | ||
RF304 (リタイア) | ||
RF500B (リタイア) | ||
RF500M |
The RF95A had earlier replaced the RF95 in all applications [the RF95A retained the RF95's item number]. The RF95A is backward compatible with existing Campbell Scientific RF systems but not compatible with RF310-series radios.
If RF95A modems are used in a network containing RF500M modems or RF500B base stations then the RF95A modems must use the -TD PROM; the data loggers must also be Table Data (-TD) or PakBus (-PB) versions.
The RF95A requires a 5 V power supply from the data logger's CS I/O port or from a PS100/A100 (non-data-logger repeater site).
RF95Aに関するよくある質問の数: 3
すべて展開すべて折りたたむ
Usually, yes. Contact Campbell Scientific for a return material authorization number (RMA) and instructions for returning the unit for repair. Additional information is available on the Repair and Calibration page.
No. The CR1000KD is designed specifically for use on the CS I/O port of the CR800, CR1000, and CR6 dataloggers.
If the RF modem has a CS I/O connector, then it should be compatible with the CR10X without the use of an SC932A. Ensure that the RF modem’s firmware is compatible with the CR10X firmware.
Note: RF modems that are not sold by Campbell Scientific will only interface with a CR10X via an SC932A or an SC105.
We've updated our privacy policy. 詳細はこちら
Update your cookie preferences. クッキーの設定を更新する