RETIRED ›
This product is no longer available.
SM4M Storage Modules with 4 MB Data Storage
利用できるサービス
修理 非対応
キャリブレーション 非対応
フリーサポート 非対応

概要

The SM4M was only compatible with our mixed-array data loggers and the DSP4 Heads Up Display. (See the Compatibility information.) It used non-volatile Flash EEPROM memory to store two million low-resolution data points (the SM16M stored eight million).

続きを読む

イメージ

詳細

The SM4M was only compatible with our mixed-array data loggers and the DSP4 Heads Up Display. (See the Compatibility information.) It used non-volatile Flash EEPROM memory to store two million low-resolution data points (the SM16M stored eight million).

The SM4M was used to augment on-site data storage, and to transport data or programs between the data logger and computer. It had a sealed canister housing fitted with a single, 9-pin D-connector. LEDs indicated when data transfer was active.

The SM4M's internal memory could store both data and programs. The memory was split into 64 kbyte blocks.

The SM4M was previously ordered as p/n 10820.

仕様

Storage Capacity 2 million low-resolution data values
Program Storage Up to eight programs with a total capacity of 128 kbytes, including labels. Storing programs does not affect available data storage capacity.
Canister Sealed
Processor Hitachi H8S
Operating System 64 kbytes, flash memory based, user downloadable
Memory Configuration User selectable for either ring style or fill-and-stop. Default is ring style.
Power Requirements 5 ±0.3 Vdc @ 100 mA (max.)
Standard Operating Temperature Range -25° to +50°C
Extended Operating Temperature Range -55° to +85°C
Dimensions 7.2 x 13.5 x 2.0 cm (2.8 x 5.3 x 0.8 in.)
Weight 181 g (6 oz)

Data Transfer Rates

Data Storage 9600, 76800 bps
Telecommunications 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps

Current Drain

Active, Processing 30 to 40 mA, average (for example, memory test)
Active, but Waiting 10 mA, average (for example, communications mode)
Typical Current during Data Storage from a Logger 15 mA, average
Low Power Standby State < 200 μA
Peak Current 60 mA (flash erase)

互換性

注意: 以下は代表的な互換性情報を示しています。互換性のある製品や互換性のない製品をすべて網羅したリストではありません。

Data Loggers

製品 互換性 注意
21X (リタイア)
CR10 (リタイア)
CR1000 (リタイア)
CR10X (リタイア)
CR23X (リタイア)
CR500 (リタイア)
CR5000 (リタイア)
CR510 (リタイア)
CR9000 (リタイア)

Communication Devices

製品 互換性 注意
DSP4 (リタイア)

互換性に関する追加情報

Computer Interface

The SC532A Interface was typically used to connect the storage module to a computer.

Data Logger Considerations

The SM4M is compatible with mixed-array data loggers. It is not compatible with data loggers that store data in a table-based format.

Data Logger Interface

The SM4M connected to a mixed-array data logger via an SC12 9-pin cable.

ダウンロード

SMS v.4.10 (6.73 MB) 06-08-2007

SMS (Storage Module Software) is a utility used to configure and retrieve data from Campbell Scientific storage modules.  It is a standalone application which is no longer included in LoggerNet starting with LoggerNet 4.0

よくある質問

SM4Mに関するよくある質問の数: 1

  1. The SM192 storage module will store 96,000 low-resolution data points. The SM4M storage module will store 2 million low-resolution data points. 

ケーススタディ

カナダ北極圏:永久凍土研究
永久凍土は熱的条件であり、その形成、存続、または消失は気候に大きく依存します。その分布、温度、および厚さは、地表の熱的レジームの変化を引き起こす自然環境の変化と人為的擾乱に反応します。気温や降水量の変化、または植生の除去、絶縁有機層の除去、森林火災、河川の移動、海岸線の浸食による地表の擾乱はすべて、地表の熱的レジームの変化を引き起こす可能性があります。 地上の気候と地下の気候の相互作用は複雑で、いくつかの要因に依存します。地上の気候の変化は、植生、有機物、積雪の断熱効果により、地下で緩和されることが多いです。通常、地表の温度変化と深部の永久凍土の変化の間には時間差があります。厚い永久凍土の場合、この時間差は数百年から数千年、薄い永久凍土の場合は数年から数十年です。  カナダ地質調査所 (GSC) がマッケンジー地域で行っている継続的な監視プログラムは、永久凍土と気候の相互作用の研究に重点を置いています。現在存在するすべての永久凍土が現在の気候と平衡状態にあるわけではありません。ボーフォート海の沖合にある永久凍土は数百メートルの厚さがあります。これは、最終氷期に棚が冷たい空気温度にさらされたときに形成されました。この永久凍土は現在、ボーフォート海の水温と不均衡な状態にあり、徐々に劣化しています。 大循環モデルは、人為的発生源により大気中の二酸化炭素濃度が倍増すると、北極圏の大部分で年間平均気温が数度上昇すると予測しています。地表温度が融解温度から 1 ~ 2 度以内である不連続永久凍土地域では、地球温暖化に伴う地表温度の変化により、永久凍土は最終的に消滅する可能性があります。地表の氷の含有量が多い場所では、この永久凍土の劣化は物理的な影響を及ぼします。最も懸念されるのは、融解時に不安定になる可能性のある土壌 (融解沈下、クリープ、または斜面崩壊) です。このような不安定性は、景観、生態系、およびインフラに影響を及ぼす可能性があります。適応策が必要かどうかを判断するには、気候変動が永久凍土に与える影響を評価する必要があります。 カナダ永久凍土監視ネットワークは、活動層と永久凍土の熱状態の長期的フィールド観測を提供します。この観測は、現在の永久凍土の状態を理解し、永久凍土の陸上気候信号とその時間的および空間的変動を検出するために不可欠です。このネットワークは、永久凍土に関する世界陸上ネットワークと、世界気象機関の地球気候観測システムの下で体系的な氷圏観測を提供するカナダの義務に貢献しています。GSC は、ネットワークのフレームワークとインフラストラクチャの調整と実装を担当しています。約 75 の熱監視サイトが政府と大学の科学者によって運営されています。 GSC は 20 か所を超える温度監視サイトのネットワークを維持しています。ボーリング......続きを読む