NRG's #40C is a MEASNET-calibrated anemometer primarily intended for wind prospecting applications. A four-pole magnet induces a sine wave voltage into a coil producing an output signal with frequency proportional to wind speed. This signal is measured by our data loggers. The #40C is constructed of Lexan. A rubber terminal boot is included. In February 2008, the #40C replaced the #40 anemometer.
Measurement Description | Wind speed |
Signal Type/Output | Low-level ac sine wave (pulse) |
Operating Temperature Range | -55° to +60°C |
Operating Relative Humidity | 0 to 100% RH |
Starting Threshold | 0.78 m/s (1.75 mph) |
Range | 1 to 96 m s-1 |
Cup Distance Constant | 3.0 m (10 ft) 63% recovery |
Cup Diameter | 5.1 cm (2 in.) |
Swept Diameter of Rotor | 19.0 cm (7.5 in.) |
Overall Assembly Height | 5.1 cm (3.2 in.) |
Weight | 0.1 kg (0.2 lb) |
注意: 以下は代表的な互換性情報を示しています。互換性のある製品や互換性のない製品をすべて網羅したリストではありません。
製品 | 互換性 | 注意 |
---|---|---|
21X (リタイア) | ||
CR10 (リタイア) | ||
CR1000 (リタイア) | ||
CR10X (リタイア) | ||
CR200X (リタイア) | ||
CR206X (リタイア) | ||
CR211X (リタイア) | ||
CR216X (リタイア) | ||
CR23X (リタイア) | ||
CR3000 (リタイア) | ||
CR500 (リタイア) | ||
CR5000 (リタイア) | ||
CR510 (リタイア) | ||
CR800 (リタイア) | ||
CR850 (リタイア) | ||
CR9000 (リタイア) | ||
CR9000X (リタイア) |
The #40C is measured by the PulseCount instruction in CRBasic and by Instruction 3 (Pulse Count) in Edlog. The #40C uses one pulse count channel on the data logger.