CR9000X Measurement and Control Datalogger
利用できるサービス
修理 対応
キャリブレーション 対応
フリーサポート 非対応

概要

The CR9000X is a large, modular multiprocessor system that provides precision measurement capabilities in a rugged, battery-operated package. It consists of a base system and a chassis with slots for up to nine user-selected I/O modules. The CR9000X is our fastest data logger, with a measurement rate of 100,000 Hz, making it ideal for rapid sampling applications.

For the entire list of available I/O modules for the CR9000X and CR9000XC, visit the Other Accessories section of the Ordering Info page for the CR9000X and the CR9000XC

Campbell Scientific also offers the CR9000XC, a compact version, that accepts up to five I/O modules. For more information, visit the CR9000XC Product Info page

続きを読む

利点と特徴

  • Up to nine I/O modules can be used to configure a system for your specific application.
  • Ideal for vehicle testing, structural or seismic monitoring, or other applications that require rapid sampling or a large number of high resolution channels
  • Throughput of 100,000 measurements per second is ideal for high demand research, such as flux and complex structural monitoring.
  • Contains an on-board 10baseT/100baseT port allowing direct Ethernet connection; an interface such as the NL100 is not required
  • CR9052IEPE and CR9052DC modules provide powerful anti-aliasing and real-time FFT capabilities that are unique to the CR9000X-series dataloggers
  • Integrated PCMCIA slot accepts memory cards up to 2 GB for stand-alone data collecting.
  • Gas Discharge Tube (GDT) protected inputs
  • Collects and stores data and controls peripherals as the brain of your system

イメージ

詳細

The CR9000X's base system includes a CR9032 CPU module, CR9041 A/D module, CR9011 power supply module, and 128-MB SDRAM memory for program and data storage. The CR9000X's internal battery has a 14-Ahr capacity.

A mix of I/O modules is selected based on the measurements required for the application. Campbell Scientific offers a large variety of modules. Individual I/O modules can be swapped out, allowing the system to be reconfigured if requirements change.

I/O modules whose model numbers end in an E (e.g., CR9051E, CR9055E) and the CR9052DC include an easy connector module. Easy connector modules allow sensor wiring to remain connected while the input module’s measurement electronics and the rest of the data logger system are used elsewhere.

The CR9000X has a choice of enclosure.  The environmental enclosure is designed for field applications, where the enclosure will be exposed to the elements. The lab enclosure is for applications where the CR9000X will reside inside a building.

CR9000X versus CR9000

In August 2004, the CR9000X replaced the CR9000. The CR9000 and CR9000X dataloggers differ in their CPU Module; the CR9000 datalogger uses the CR9031 and the CR9000X datalogger uses the CR9032.

The CR9032 CPU module supports a measurement rate of up to 100,000 Hz, provides a 180 MHz clock speed, and adds a built-in RS-232 port, 10baseT/100baseT port, CS I/O port, and PC-card slot. The built-in ports enable communication without using the special interfaces (e.g., PLA100, TL925, NL105) that were required for the retired CR9000 datalogger. The PC-card slot allows the CR9000X to store data on a Type I, Type II, or Type III PCMCIA card, or on a CompactFlash® card if an adapter is used.

A CR9000 may be upgraded to a CR9000X by replacing the CR9031 CPU module with the CR9032 CPU module.

仕様

-NOTE-
  • Additional specifications are listed in the CR9000X(C) Specifications Sheet.
  • For the CR9000X, the current drain, weights, and specific number of input/output channels depend on the I/O modules chosen.
Operating Temperature Range
  • -25° to +50°C (standard)
  • -40° to +70°C (extended)
  • Non-condensing environment
Analog Inputs 28 single-ended or 14 differential per CR9050, CR9051E, or CR9055(E) module
Pulse Counters 12 per CR9071 module
Communications Ports
  • CS I/O
  • RS-232
  • 10baseT/100baseT
Switched 12 Volt 1 terminal
Digital I/O
  • Certain digital ports can be used to count switch closures.
  • 1 SDM and 8 outputs per CR9060 module or 16 I/Os per CR9071 module
Analog Voltage Accuracy ±(0.07% of reading + 4 A/D counts), -25° to +50°C
ADC 16-bit
Power Requirements 9.6 to 16 Vdc
Communication Protocols SDM
Warranty 3 years
Dimensions
  • 40.1 x 24.9 x 20.3 cm (15.8 x 9.8 x 8 in.) for lab enclosure
  • 45.7 x 34.9 x 22.9 cm (18 x 13.5 x 9 in.) for field enclosure
Weight
  • 13.6 kg (30 lb) with modules in lab enclosure
  • 19.1 kg (42 lb) with modules in field enclosure

互換性

注意: 以下は代表的な互換性情報を示しています。互換性のある製品や互換性のない製品をすべて網羅したリストではありません。

Software

製品 互換性 注意
LoggerNet Version 2.0 or higher
PC200W (リタイア)
PC400 Version 1.0 or higher
RTDAQ Version 1.0 or higher
Short Cut
VISUALWEATHER Version 2.0 or higher

互換性に関する追加情報

Compatibility with Retired Products

Customers can add CR9000X dataloggers to networks containing the older CR9000 or CR9000C dataloggers. I/O modules other than the CR9080 can be used with either the CR9000 or CR9000X. CR9000 communication interfaces (i.e., NL105, BLC100, TL925, PLA100) are not compatible with the CR9000X, and therefore have been retired.

Sensors

With several channel types, the CR9000X is compatible with many sensors, including thermocouples and 4 to 20 mA sensors.

Measurement and Control Peripherals

Measurement and control peripherals typically used with the CR9000X are our AM25T 25-Channel Solid State Multiplexer, SDM-CAN Interface, SDM-INT8 Eight Channel Interval Timer, and SDM-SIO4 Serial Input/Output Module. Other measurement and control peripherals are compatible but they do not support the CR9000X datalogger's maximum measurement rate and are therefore impractical for most CR9000X applications.

Communications

The CR9000X typically communicates with a PC via direct connect or Ethernet. Because the CR9000X has an on-board 10baseT/100baseT port, an Ethernet interface such as the NL201 is not required. 

Storage capacity can be increased by using a PC or CompactFlash card. The CR9000X's PCMCIA card slot supports one Type I, Type II, or Type III PC Card or the CF1 adapter and one CompactFlash (CF) card.

The storage capacity of Type II cards exceeds 1 GB. Type III cards provide data storage capacities exceeding 1 GB but may not be suitable for all environments. Campbell Scientific offers several CF cards that have passed our ESD testing and operate properly with our data loggers (see Ordering tab). Please note that the PCMCIA and CompactFlash cards need to be industrial-grade and have a storage capacity of 2 GB or less.

Other communication peripherals are compatible but they do not support the CR9000X datalogger's maximum measurement rate and are therefore impractical for most CR9000X applications.

Enclosures

Two enclosures are offered for the CR9000X. The 8253 fiberglass environmental enclosure is designed for field applications where the enclosure will be exposed to the elements. The 8255 lab enclosure is for applications where the CR9000X will reside inside a building.

Software

CRBasic, the CR9000X's full programming language, supports simple or complex programming and many on-board data reduction processes. CRBasic is included in RTDAQ, LoggerNet, and PC400.

RTDAQ Real-Time Data Acquisition Software must be ordered separately; the CR9000X is also compatible with other Campbell Scientific software.

ダウンロード

CR9000X OS v.6 (4.04 MB) 23-01-2012

Current Operating System, Compiler and CR9000X support files for the CRBasic Editor. Requires the Device Configuration Utility, LoggerNet or RTDAQ to upload.

Use of this file will update the datalogger support files for the CRBasic Editor included in LoggerNet and RTDAQ.

更新履歴をみる

PC9000 Patch v.5.3.1 (21.9 MB) 02-03-2007

RETIRED PRODUCT

Upgrade PC9000 version 5.0, 5.1, 5.2 or 5.3 to 5.3.1; no intermediate steps are required.

PC9000 5.0, 5.1, 5.2 or 5.3 must be installed on your machine.

更新履歴をみる

よくある質問

CR9000Xに関するよくある質問の数: 45

すべて展開すべて折りたたむ

  1. There are two ways to upgrade an operating system:

    Method 1

    1. Connect to the CR9000X using the serial link or the Ethernet link.
    2. Use the RTDAQ | Clock/Program Tab | Send Program… button.
    3. In the Files Type box in the file browser window, use the drop-down arrow to select OBJ Files (*.obj). Browse to the computer file where the desired operating system resides.
    4. Double-click the file, or click the Open button. A warning will appear.
    5. After reading the warning, click Yes to begin downloading the new operating system.

    Method 2

    1. Download and install the Device Configuration Utility software, or launch it from RTDAQ.
    2. Connect the CR9000X RS-232 port to the computer.
    3. Select CR9000X from the list in the Device Configuration Utility.
    4. Select the Send OS tab, and follow the instructions displayed in the software interface screen.
  2. The CR9000X and CR9000XC differ only in the number of I/O cards they can hold. The CR9000X can hold 9 I/O cards, and the CR9000XC can hold 5 I/O cards. We provide both sizes to accommodate our customers; the same I/O cards can be used in either chassis.

  3. The CR3000 program will have to be modified so that each measurement or control instruction includes the appropriate module number. Some parameters might differ as well.
  4. If small amounts of data are transferred per transmission, it will not be a problem. Larger amounts of data can overrun buffers in the modem, causing lost data. In that situation, lower the baud rate on the data logger to avoid the issue.

  5. Yes. The simplest method is to use conditional program statements that execute most of the code based on time. For example, the data could be scheduled to log at 6 a.m. and finish at 8 p.m. using CRBasic instructions such as TimeIntoInterval(). Another option is to use an IfThen/EndIf construction that does a logical test of light-level measurements based on a light sensor. An additional option is to use calculated sunrise and sunset times along with a combination of RealTime() and Case instructions.

    For more information, see the “Decisions, Decisions, Decisions…” article. 

  6. Use the full-bridge instruction, BrFull(). An example program for the CR1000 can be found in the “Datalogger Programming” section of the “ST350 Strain Transducer Instruction Manual.”

  7. Common causes include the following:

    • Loss of power to the data logger and the program Run On Power-up attribute not being set (For help with this, see the “How Do You Run?” article.)
    • A FillStop instruction in a CRBasic program used to set data tables to stop storing new data when full
    • Logical conditions for writing to data tables that do not evaluate as TRUE

  8. The data logger will not reset the SW12 unless it is done under program control using the SW12() or PortSet() instructions, or unless the data logger compiles or recompiles a program. This could be done when a new program is sent to the data logger, or if the power is cycled.

  9. Yes. Both the RavenXTV (Verizon) and the RavenXTG (AT&T) are available.

ケーススタディ

アラスカ:水力発電
海洋水力発電は、再生可能エネルギー ポートフォリオの新興分野です。水力発電装置は、波、潮流、海流、または川の流れのエネルギーを電力に変換します。水流を使用して生成される電力は、風力や太陽光などの他の予測しにくい再生可能エネルギー源と比較して、これらの源の予測可能な動作のため、非常に魅力的です。アラスカの田舎の村のほとんどは川沿いにあり、電力網から外れています。これらの村は電力を地元のディーゼル発電機に依存していますが、そのディーゼルは道路で村にアクセスできないため、はしけまたは飛行機で村に運ばれる必要があります。その結果、電力コストが 1 キロワット時あたり 70 セントを超えることがあり、これは電力網に接続する顧客が支払う金額の 10 倍以上になる可能性があります。これらの田舎の村の人々は、通常、エネルギーの高額なコストを支払う余裕が最もありません。アラスカの田舎の村だけでなく、河川システムに近い地域で遠隔地の電力を個人、商業、または科学的に必要とする人は誰でも、水力発電の使用から恩恵を受けることができます。オセアナ エナジー カンパニーは潮力エネルギー収集装置を開発しており、アラスカ エネルギー庁 (AEA) からの助成金を受けて、より厳しい環境である河川での装置の適用性を評価してきました。河川で水力発電装置を設置する場合、乱流と浮遊物によって大きな課題が生じます。 Oceana は、河川でのパフォーマンス データを取得する目的で、2014......続きを読む
オレゴン州: 橋梁構造応答
テュアラティンのカマルズ橋は、4 スパンの鋼製箱桁橋で、オレゴン州運輸局 (ODOT) の州全体の構造健全性監視 (SHM) プログラムの一部に含まれていました。カマルズ橋は、南行きの州間高速道路 205 号線と州間高速道路 5 号線が交差する地点にあります。ODOT は、温度や交通負荷の変化に対するこの橋の構造的応答の監視を改善しようとしていました。これは、複合コンクリート橋床版の両側にある縦方向の箱桁と横方向の横梁の間に疲労亀裂が発生したため必要でした。 橋梁の上部構造の横方向およびねじり方向の剛性が高く、水平方向の曲線が大きいため、疲労亀裂の性質と原因を特定するのは困難でした。亀裂のある疑わしい接合部は改修されましたが、ODOT は改修の効果を確認するための監視システムを望んでいました。 ODOT は、橋の監視システムの設計と設置にエンジニアード モニタリング ソリューションズ......続きを読む
ペンシルバニア州: 橋梁の疲労寿命の評価
シッピングポート橋は、ペンシルバニア州ビーバー郡のオハイオ川に架かっています。1961 年に建設されたこの主要な川の横断橋は、長さ 1,300 フィートを超える 3 径間のデッキ/トラス橋です。より大規模な評価および改修プロジェクトの一環として、リーハイ大学の大型構造システム向け先端技術 (ATLSS) 研究センターがこの橋の現場テストを実施しました。作業範囲には、形状と重量がわかっているテスト トラックを使用した制御荷重テストと、通常交通時の橋の長期モニタリングが含まれていました。その後、ATLSS は収集したデータを使用して、橋の重要なポイントの残りの疲労寿命を推定しました。 ひずみゲージと変位センサーは、疲労に敏感な場所や、橋の全体的な荷重分布特性と一般的な動作についての洞察が得られる場所など、選択されたスパン全体にわたって設置されました。データは、Campbell Scientific CR9000X データロガーを使用して収集され、その後、ワイヤレス モデムを介して、300 マイル離れたペンシルベニア州ベツレヘムの......続きを読む
ニューヨーク:橋梁荷重試験
リーハイ大学の研究者は、50 年以上にわたり、橋梁、建物、その他の構造物の現場計測と試験の最前線に立ってきました。彼らは、高速道路や鉄道構造物の現場試験と評価に関する膨大なデータベースと豊富な経験を開発してきました。現場試験と評価は、構造研究の中でも特に難しい分野です。実際の負荷がかかった状態で構造物の実際の動作をリアルタイムで正確に評価できる唯一の方法です。現場測定は、実験室試験とコンピューター モデリングを実際の構造物の動作に結び付けて検証するリンクです。 構造挙動を正確に解釈するには正確なデータが必要であることはよく知られています。しかし、数百フィート上空の川の上空で風と寒さの中でデータを収集するのは、実験室で収集するよりもはるかに難しいことは明らかです。環境上の障害以外にも、測定値を正確に解釈する前に対処しなければならない変数が多数あります。したがって、データ収集システム、センサー、構造挙動を徹底的に理解することが不可欠です。最も重要なのは、このような悪条件下でも一貫して機能するデータ収集システムです。リーハイ大学の研究者は、Campbell Scientific CR9000 測定および制御システムが非常に堅牢で、最も過酷な現場環境にも耐えられることを発見しました。これらは、私たちのインフラストラクチャ監視プログラムの主力製品です。 最近完了した現場テスト プロジェクトの例には、現在大規模な改修工事が行われているニューヨーク市のウィリアムズバーグ橋の現場測定と長期リモート モニタリングが含まれます。このプロジェクトの大部分は、南と北の内側と外側の道路の両方にある既存のコンクリート充填グリッド デッキを鋼鉄直交異方性デッキに交換することです。包括的なラボ テスト プログラムに加えて、南の外側の道路では詳細な現場計測とテスト プログラムも実施されました。この研究は、現場での応力範囲を調査し、この複雑な構造システムの挙動とラボの応答との関係をより正確に特徴付けるために実施されました。データは CR9000 を使用して収集されました。制御された負荷テスト中、データは 82......続きを読む
ノバスコシア州: 将来のプロジェクトに向けた橋梁パフォーマンスの監視
コンフェデレーション橋は、海水上に建設された世界最長の連続プレストレストコンクリート箱桁橋の 1 つであり、氷に覆われた海上に建設された橋としては最長のスパンです。カナダのプリンスエドワード島のボーデンからニューブランズウィック州のケープ トルメンタインまで 13 km にわたっています。コンフェデレーション橋の建設は畏敬の念を抱かせる出来事でした。現在も継続中の長期にわたる監視および研究プロジェクトにより、この橋は工学上の驚異としてさらに高い評価を受けています。 ノーサンバーランド海峡の厳しい環境に耐えられるように建設されたコンフェデレーション橋は、100 年の耐用年数を実現するように設計されました。橋の短期および長期の性能をより深く理解するために、建設中に複数年にわたる監視および研究プロジェクトが立ち上げられました。この研究は、将来の長スパン橋の荷重モデルの開発に貢献します。 計装 監視機器には、橋の建設中に設置されたものもあり、500 台以上のひずみ測定装置、450 個の温度センサー、28 個の氷荷重パネル、12 個の傾斜計、76 個の振動センサー、水中ソナー装置などが含まれています。6 台の Campbell......続きを読む
イギリス:車両性能および耐久性試験
Campbell Scientificのデータ取得システムは、英国を拠点とする自動車メーカー、ローバーの車両テストに広く使用されています。ローバーはロングブリッジ、ソリハル、ゲイドンの各工場で、Campbell Scientificのデータ取得システムを使用して新車をテストしています。ローバーは世界中でCampbell Scientificの機器を使用して、極度の高温や低温の気候における性能と耐久性をテストしています。同社は CR9000、CR7、CR10X を組み合わせて使用​​しており、50 台を超えるCampbell Scientific システムを保有しています。...続きを読む

記事とプレスリリース


下記の製品は置き換えられました

Privacy Policy Update

We've updated our privacy policy.  詳細はこちら

Cookie Consent

Update your cookie preferences.  クッキーの設定を更新する