RETIRED ›
This product is no longer available and has been replaced by: CR300,CR310.
CR200X Datalogger
利用できるサービス
修理 対応
キャリブレーション 非対応
フリーサポート 対応

概要

The CR200X, our smallest lowest-cost data logger, provides stand-alone operation in harsh, remote environments. It reads input from one or two sensors, then transmits the data using communication peripherals. CRBasic, its full programming language, supports simple or complex programming. Multiple CR200Xs can be configured as a network, or units can be deployed individually.

続きを読む

利点と特徴

  • Ideal applications include wind energy, rural water, water level/flow, aquaculture, water quality
  • Campbell Scientific’s smallest, lowest cost data logger
  • Gas Discharge Tube (GDT) protected inputs
  • Optimal for measuring one or two simple sensors
  • Makes SDI-12, single-ended analog, pulse, switch closure, and bridge measurements
  • Battery-backed clock that ensures accurate time is maintained while data logger is disconnected from battery power
  • Program with LoggerNet, PC400, or Short Cut to fit your setup
  • PakBus, Modbus, and SDI-12 protocols supported

イメージ

CR200x standard view top
CR200x standard view bottom
CR200x standard view front
CR200x standard view iso
CR200x standard view left
CR200x standard view right

CAD ファイル:

詳細

The CR200X has several input channels for measuring a variety of sensors. Gas discharge tubes provide rugged electrostatic discharge protection for the inputs.

The CR200X does not make differential measurements and is not compatible with SDM devices, multiplexers, or thermocouples (refer to the Compatibility information for compatible sensors, peripherals, and software). Recalibration services are not offered for the CR200X datalogger.

仕様

-NOTE- Note: Additional specifications are listed in the CR200X-Series Specifications Sheet.
Maximum Scan Rate 1 Hz
Analog Channels
  • The single-ended analog inputs can also be used as control ports.
  • 5 single-ended (no differential) individually configured
Pulse Count Channels 2
Switched Excitation Channels 2 voltage
Digital Ports
  • Certain digital ports can be used to count switch closures.
  • 2 I/O
Communication Ports 1 RS-232
Switched Battery Port 1
Input Voltage Range 0 to 2500 mV
Analog Voltage Accuracy ±(0.25% of reading + (1.2 mV)x(offset)) at -40° to +50°C
Analog Voltage Resolution 0.6 mV
A/D Bits 12
Operating Temperature -40° to +50°C
Power Requirements 7 to 16 Vdc
Typical Current Drain
  • ~0.2 mA (quiescent)
  • ~3 mA (active)
Clock Accuracy
  • 8.2 min./month (@ -40° to +50°C)
  • 1 min./month (@ +25°C)
Protocols Supported PakBus (leaf node only), SDI-12
CE Compliance Standards to which Conformity Is Declared IEC61326:2002
Warranty 3 years
Dimensions 14.0 x 7.6 x 4.8 cm (5.5 x 3.0 x 1.9 in.)
Weight 242 g (8.5 oz)

Memory

Final Storage 512 kB of flash memory for approximately 125,000 data points
Operating System 106 kB of flash memory
Intermediate Storage 8 kB of SRAM for communication buffers, calculations, variables, etc.

互換性

注意: 以下は代表的な互換性情報を示しています。互換性のある製品や互換性のない製品をすべて網羅したリストではありません。

Measurement and Control

製品 互換性 注意
AM16/32B
AM25T

Sensors

製品 互換性 注意
014A-L
03002-L
03101-L
034B-L
05103-45-L (リタイア)
05103-L
05106-L (リタイア)
05305-L
083E-L (リタイア)
092-L (リタイア)
107
108
109
109SS-L
110PV-L (リタイア)
237-L (リタイア)
255-100
27106T-L
43347-L
52202-L
A100LK-L
CMP11-L (リタイア)
CMP21-L
CMP3-L
CMP6-L (リタイア)
CS100
CS106
CS11-L
CS215-L (リタイア)
CS300-L (リタイア)
CS410-L (リタイア)
CS451
CS456
CS460-L (リタイア)
CS470 (リタイア)
CS471 (リタイア)
CS475A-L (リタイア)
CS475-L (リタイア)
CS476-L (リタイア)
CS477-L (リタイア)
CS511-L
CS526-L (リタイア)
CS547A-L
CS616
CS625 (リタイア)
CS650
CS655
CS700-L
CSAT3 (リタイア)
CSIM11-L
CSIM11-ORP-L
ENVIROSCAN (リタイア)
HC2S3-L (リタイア)
HMP155A-L
HMP60-L
ICEFREE3A (リタイア)
ICEFREE3V (リタイア)
LI190SB-L (リタイア)
LI200X-L (リタイア)
LWS
OBS-3+ (リタイア)
OBS300 (リタイア)
OBS500 (リタイア)
OBS501 (リタイア)
P2546A-L
SEN12512 (リタイア)
SR50A-L (リタイア)
TB4-L
TB4MM-L
TE525-L
TE525MM-L
TE525WS-L
WINDSONIC1-L
WINDSONIC4-L
WXT520 (リタイア)

Software

製品 互換性 注意
LoggerNet Version 2.1 or higher
PC200W (リタイア)
PC400 Version 1.0 or higher
PCONNECT (リタイア) Version 3.0 or higher
PCONNECTCE (リタイア) Version 2.0 or higher
Short Cut
VISUALWEATHER Version 2 or higher

互換性に関する追加情報

Communications

The CR200X can communicate with a PC via direct connect, NL201 Network Link Interface, NL240 Wi-Fi Network Link, MD485 multidrop modem, and digital cellular modems. Data can be viewed on an iOS device, an Android device, CD295 DataView II Display, or a user-supplied PDA. To use an iOS or Android device, go to the Apple Store or Google Play and download our LoggerLink Mobile Apps free of charge. User-supplied PDAs require either PConnect or PConnectCE software.

Measurement & Control Peripherals

The CR200X is not compatible with SDM devices and multiplexers.

Sensors

The CR200X can measure a variety of sensors including SDI-12 sensors and 4 to 20 mA sensors. It cannot make differential measurements and is not compatible with the freezing-rain/ice, fuel moisture/temperature, geographic position, present weather, soil heat flux, soil matric water potential, and strain sensors listed on our price lists.

Enclosures

Applications with minimal power requirements can use the ENC200 enclosure to house the data logger and the pn 16869 sealed rechargeable battery. The ENC200 cannot house a barometer or a battery that is larger than the pn 16869. However, an ENC10/12 or ENC12/14 enclosure is adequate for most CR200X-based systems.

Power Supplies

The CR200X uses an external power supply and has a built-in regulator. When connected to the on-board charging circuit, the sealed rechargeable battery should be 7 A h or smaller. Using larger batteries with the data logger's built-in charger may result in excessive PC board heating. This is especially a concern when the battery is deeply discharged or failing with a shorted cell. Campbell Scientific also recommends that solar panels be 10 W or less and wall chargers be 1 A or smaller.

ダウンロード

CR200X Series OS v.04 (1.29 MB) 22-09-2015

Execution of this download installs the Operating System and Compiler on your computer for the following dataloggers:CR200X, CR206X, CR211X, CR216X and CR295X.  It also updates the support files for the CRBasic Editor.  

Note: Newer CR206X dataloggers (serial # ≥ 19122) and newer CR211X dataloggers (serial # ≥ 19143) have 250 mW radios that must use OS 3 or higher for their datalogger operating system.

更新履歴をみる

よくある質問

CR200Xに関するよくある質問の数: 37

すべて展開すべて折りたたむ

  1. Yes. The simplest method is to use conditional program statements that execute most of the code based on time. For example, the data could be scheduled to log at 6 a.m. and finish at 8 p.m. using CRBasic instructions such as IfTime(). Another option is to use an IfThen/EndIf construction that does a logical test of light-level measurements based on a light sensor. An additional option is to use calculated sunrise and sunset times along with a combination of RealTime() and Case instructions.

    For more information, see the “Decisions, Decisions, Decisions…” article. 

  2. Not directly. If the CS15-L is connected to a CR200(X) datalogger, the data logger can take the ac measurement and control a solid-state relay based on some threshold within the data logger program. The solid-state relay can then control other relays, solenoids, or motor starters. (Use of a solid-state relay is preferred because the data logger can trigger it with a small 5 Vdc mA signal.) For more information, see the “Measurement and Control Peripherals” section of the operator’s manual.

  3. Current data loggers compatible with the BMP5 Direct SDK are the CR200X-series, CR1000, CR3000, CR800, and CR850.

    Retired compatible data loggers include the CR10X-PB, CR23X-PB, and CR510-PB. These data loggers must have the optional PakBus operating system installed, which is available on the Downloads page of our website.

  4. The CR200X-series and the retired CR200-series dataloggers are NOT compatible with SDMs or multiplexers. If more channels are needed or may be needed in the future, consider purchasing a CR800, CR850, or CR1000 instead.

  5. 技術的には、SRM-5A は CR200X シリーズ データロガーと互換性がありますが、これらのデータロガーで使用するのはより複雑です。SRM-5A を CR200X シリーズ データロガーで使用するには、SRM-5A をステーション モデムの DTE 位置に配置する必要があります。さらに、SRM-5A とデータロガーの RS-232 ポート間の接続を完了するには、ユーザー提供のアダプタとジェンダー チェンジャーが必要です。詳細については、Campbell Scientific にお問い合わせください。

  6. If small amounts of data are transferred per transmission, it will not be a problem. Larger amounts of data can overrun buffers in the modem, causing lost data. In that situation, lower the baud rate on the data logger to avoid the issue.

  7. The internal battery is not rechargeable. In the case of low internal battery voltage, data will only be maintained as long as a power supply is connected. Collect all data from the data logger before disconnecting the power.

    The battery, a 15598, is not user replaceable. The data logger should be returned to Campbell Scientific to have the battery replaced. To request a return material authorization (RMA) number, follow the steps listed on our Repair and Calibration page.

  8. Yes. Both the RavenXTV (Verizon) and the RavenXTG (AT&T) are available.

  9. Some Campbell Scientific sensors with an RS-232 output are supported in Short Cut. Because of the large variety of serial data formats, other sensors require creating a program in the CRBasic Editor. CRBasic Editor is included in several of the purchased software packages, such as LoggerNet. For more information, see the “Interfacing Serial Sensors with Campbell Scientific Dataloggers” application note.

    Note: The CR200X-series dataloggers have very limited serial capabilities.

  10. いいえ、動作しません。SC32B は次の目的で使用されます。

    • データロガーのロジックレベル(CS I/O ポート上)を RS-232 レベルに変換します

    • データロガーを RS-232 周辺機器から光学的に分離します

ケーススタディ

サウスダコタ州: 運河を利用した灌漑システム
サウスダコタ州西部のブラックヒルズのすぐ北にある半乾燥地域には、農業に適した広大な台地が広がっています。この地域はさまざまなニーズがあるため、灌漑を注意深く監視する必要があります。ベル フーシェ川の北側の土地は、主に水分を保持する粘り気のあるガンボ土で構成されています。適切な排水が行われないと、余分な水が下層土に浸透し、塩分が表面に上がり、その地域は灌漑できなくなります。一方、ベル フーシェ川の南側の土地は水を多く必要とする砂質ローム土で、頻繁に水やりが必要です。 この地域の複雑な灌漑ニーズを認識し、開拓局はベル フォーシュ灌漑地区 (BFID) を設立しました。BFID は、94 マイルの幹線運河、450 マイルの開放側溝、および複数のダムを使用して、202 km 2 (50,000 エーカー) を超える耕作地に水を供給する灌漑システムの管理、運用、および保守を担当しています。 この地域は度重なる干ばつに見舞われているため、地域全体の灌漑ニーズを満たす十分な水供給を確保するには、節水が不可欠です。BFID は、運河の水位変動を減らし、水の損失を減らして供給効率を高めたいと考えていました。これを実現するには、BFID の運河チェック構造を自動化する必要がありました。 BFID は、プロジェクトの調整、設置、アドバイス、システム構成、およびトラブルシューティングを支援するため、統合コンサルティングおよびサービス会社である......続きを読む
ワシントン:ALERTステーションの改修
アメリカ国立気象局 (NWS) は、セントヘレンズ山周辺に自動洪水警報ステーションのネットワークを運営しています。これらのステーションの多くは、もともと火山噴火直後に地震監視ステーションとして設置されました。その後、これらのステーションは洪水警報用に再利用されました。 ネットワーク内のステーションは降雨量を測定し、テレメトリに ALERT 無線プロトコルを使用します。元のハードウェアは老朽化しており、スペアパーツは入手できなくなりました。ネットワークからのデータは、NWS 降雨量予測モデルの調整に使用される 30 年以上の履歴データがあるため重要です。 オリジナルの ALERT 洪水警報装置の改造にはCampbell Scientific の装置が選ばれました。Campbell Scientific が選ばれたのは、モジュール性と柔軟性のためです。柔軟性により既存の ALERT......続きを読む
バージニア州: ALERT システム
1970 年代後半、アメリカ国立気象局は、アメリカ東部のアパラチア地域全体に統合洪水観測警報システム (IFLOWS) を導入しました。IFLOWS の協力機関であるバージニア州緊急事態管理局 (VDEM) は、ALERT 通信プロトコルを使用して、このシステム用の計測ステーションの広範なネットワークを開発しました。30年の使用を経て、VDEM のネットワークは、老朽化し​​たプログラム不可能な ALERT 送信機 300 台近くで構成されていました。その頃までに、監視技術は大きく進歩していました。ネットワークで使用されている ALERT プロトコルは一方向の通信プロトコルであり、機能が強化された新しいプロトコルが利用可能でした。さらに、新しい......続きを読む
イギリス: 風監視システム
より信頼性の高い気象情報にアクセスできるように、タイン港は既存の気象ステーションに 2 つの新しい気象ステーションを追加しました。ステーションは 1 分ごとに、または必要に応じてオンデマンドでデータを港のコンピューター ネットワークに転送し、港の運営を支援します。 タイン港は英国で 2 番目に大きな石炭港であり、ヨーロッパ最大の木質ペレット取扱港でもあります。港では複数のクレーンが稼働しており、そのすべてが法律により風速と風向を監視して安全な作業環境を確保する必要があります。タイン港は長年にわたり、規制を遵守し、従業員の安全を守るために、Campbell Scientificの監視システムの信頼性を信頼してきました。 監視ステーションには、風速と風向を測定する超音波風速計が備えられており、信頼性が高く、堅牢で、過酷な海洋環境に最適です。風速計はクレーンの上部に取り付けられ、風のデータを CR200X データロガーに送信します。CR200X データロガーは、クレーンの下部に近い運転席の外側に固定されています。測定値は RS-485 接続を介して送信されるため、比較的長距離でも良好な信号品質が確保されます。運転者がキャビンに入る前に、風の状態をチェックして、その高度で作業を進めることができるかどうかを判断します。データロガーの筐体には CD295......続きを読む

Privacy Policy Update

We've updated our privacy policy.  詳細はこちら

Cookie Consent

Update your cookie preferences.  クッキーの設定を更新する