RETIRED ›
This product is no longer available.
083E-L Temperature and Relative Humidity Sensor
利用できるサービス

概要

The 083E, manufactured by Met One, is a temperature and relative humidity sensor that is commonly used with the WMS100 for wind-farm power performance measurements. The sensor is made of corrosion-resistant aluminum and polymer, and it is water-tight. Use this sensor to measure the full range of relative humidity, from 0 to 100%.

続きを読む

イメージ

083E sensor with the 41003-5 shield and crossarm (sold separately)
083E sensor with the 41003-5 shield and crossarm (sold separately)
083E sensor with the 41003-5 shield and crossarm (sold separately)
083E sensor with the 41003-5 shield and mast (sold separately)

詳細

The 083E Relative Humidity Sensor measures variance in the capacitance change of a one micron thick dielectric polymer layer. This film absorbs water molecules through a metal electrode, and causes a capacitance change that is proportional to relative humidity. The thin polymer layer reacts quickly, providing up to 90% of the final value of relative humidity in fewer than five seconds. The sensor’s response is essentially linear, with small hysteresis, and negligible temperature dependence.

Temperature is measured with an internal thermistor.

仕様

Measurement Description Temperature, relative humidity
Signal Type/Output Analog voltage
Input Power 4 mA at 12 Vdc (10 to 14 Vdc)
Diameter 1.91 cm (0.75 in.)
Length 19.05 cm (7.5 in.)
Weight 70.9 g (2.5 oz)

Relative Humidity

Sensor Thin film polymer capacitor
Measurement Range 0 to 100% RH
Response Time 10 s (with 2 m s-1 aspiration)
Temperature Coefficient 0.04% RH per °C
Accuracy ±2.0% from 0 to 100% humidity
Output Signal Range 0 to 1 Vdc

Air Temperature

Sensor Thermistor (precision multi-element)
Operating Temperature Range -50° to +50°C
Accuracy ±0.10°C (0.18°F)
Output Resistive

互換性

注意: 以下は代表的な互換性情報を示しています。互換性のある製品や互換性のない製品をすべて網羅したリストではありません。

Data Loggers

製品 互換性 注意
21X (リタイア)
CR10 (リタイア)
CR1000 (リタイア)
CR1000X (リタイア)
CR10X (リタイア)
CR200X (リタイア)
CR206X (リタイア)
CR211X (リタイア)
CR216X (リタイア)
CR23X (リタイア)
CR300 (リタイア)
CR3000 (リタイア)
CR310
CR500 (リタイア)
CR5000 (リタイア)
CR510 (リタイア)
CR6
CR800 (リタイア)
CR850 (リタイア)
CR9000 (リタイア)
CR9000X (リタイア)

互換性に関する追加情報

Mounting

When exposed to sunlight, the 083E must be housed in a 41003-5 or RAD14 naturally aspirated radiation shield. The 41003-5 and RAD14 attach to a crossarm, mast, or user-supplied pipe with a 2.5 to 5.3 cm (1.0 to 2.1 in.) outer diameter.

The RAD14 uses a double-louvered design that offers improved sensor protection from driving rain, snow, and insect intrusion. A better measurement can be made by providing lower self-heating in bright sunlight combined with higher temperatures (> 24°C [~75°F]) and low wind speeds (< 2 m s-1 [~4.5 mph]).


よくある質問

083E-Lに関するよくある質問の数: 3

すべて展開すべて折りたたむ

  1. すべてのセンサに異なるケーブル終端オプションがあるわけではありません。特定のセンサで利用可能なオプションは、センサ製品ページの注文情報エリアの 2 つの場所で確認できます。

    モデル番号
    ケーブル終端オプション リスト
    センサが –ET、–ETM、–LC、–LQ、または –QD バージョンで提供されている場合、そのオプションが利用可能かどうかはセンサモデル番号に反映されます。たとえば、034B は 034B-ET、034B-ETM、034B-LC、034B-LQ、および 034B-QD として提供されています。

    その他のすべてのケーブル終端オプション (利用可能な場合) は、センサ製品ページの注文情報エリアの「ケーブル終端オプション」の下にリストされています。たとえば、034B-L 風力発電セットは、034B-L 製品ページの注文情報エリアに示されているように、–CWS、–PT、および –PW オプションで提供されています。

    注意: 新しい製品が在庫に追加されると、通常は複数のモデル番号を作成するのではなく、1 つのセンサモデルの下に複数のケーブル終端オプションをリストします。たとえば、HC2S3-L には、HC2S3-LC モデルではなく、CS110 に接続するための –C ケーブル終端オプションがあります。

  2. Most Campbell Scientific sensors are available as an –L, which indicates a user-specified cable length. If a sensor is listed as an –LX model (where “X” is some other character), that sensor’s cable has a user-specified length, but it terminates with a specific connector for a unique system:

    • An –LC model has a user-specified cable length for connection to an ET107, CS110, or retired Metdata1.
    • An –LQ model has a user-specified cable length for connection to a RAWS-P weather station.

    If a sensor does not have an –L or other –LX designation after the main model number, the sensor has a set cable length. The cable length is listed at the end of the Description field in the product’s Ordering information. For example, the 034B-ET model has a description of “Met One Wind Set for ET Station, 67 inch Cable.” Products with a set cable length terminate, as a default, with pigtails.

    If a cable terminates with a special connector for a unique system, the end of the model number designates which system. For example, the 034B-ET model designates the sensor as a 034B for an ET107 system.

    • –ET models terminate with the connector for an ET107 weather station.
    • –ETM models terminate with the connector for an ET107 weather station, but they also include a special system mounting, which is often convenient when purchasing a replacement part.
    • –QD models terminate with the connector for a RAWS-F Quick Deployment Station.
    • –PW models terminate with the connector for a PWENC or pre-wired system.
  3. Many Campbell Scientific sensors are available with different cable termination options. These options include the following:

    • The –PT (–PT w/Tinned Wires) option is the default option and does not display on the product line as the other options do. The cable terminates in pigtails that connect directly to a data logger.
    • In the –C (–C w/ET/CS110 Connector) option, the cable terminates in a connector that attaches to a CS110 Electric Field Meter or an ET-series weather station.
    • In the –CWS (–CWS w/CWS900 Connector) option, the cable terminates in a connector that attaches to a CWS900-series interface. Connection to a CWS900-series interface allows the sensor to be used in a wireless sensor network.
    • In the –PW (–PW w/Pre-Wire Connector) option, the cable terminates in a connector that attaches to a prewired enclosure.
    • In the –RQ (–RQ w/RAWS Connector) option, the cable terminates in a connector that attaches to a RAWS-P Permanent Remote Automated Weather Station.

    Note: The availability of cable termination options varies by sensor. For example, sensors may have none, two, or several options to choose from. If a desired option is not listed for a specific sensor, contact Campbell Scientific for assistance.