RETIRED ›
This product is no longer available.
A6REL-12 6-Channel Relay Driver with Manual Override
利用できるサービス
修理 非対応
フリーサポート 対応

概要

You can control up to 12 external ac or dc devices using the six internal relays of the A6REL-12. Each relay set can be controlled manually or by a data logger.

続きを読む

利点と特徴

  • UL/CUL approved product

イメージ

詳細

The A6REL-12's internal relays are dual single-pole double-throw. Each of the six relays has a three position toggle switch; "on" and "off" for manual override, and "auto" for data logger control. In the on position, the common and normally open contacts are shorted. In the auto position, the state of a relay is controlled by a data logger control port.

A6REL-12's with serial numbers 1445 and higher are UL-approved.

仕様

Function Controls up to 12 external ac or dc devices.
Number of Channels 6
Operating Voltage 12 Vdc nominal (8.4 to 24 Vdc)
Current Drain at 12 Vdc
  • 6 µA quiescent
  • 30 mA per active LED (switch ON or AUTO active)
Toggle Switch ON/OFF manual override; AUTO for data logger control
Relays dual single pole double throw, break before make
Contact Material Gold-clad silver
Coil Resistance 720 Ω ±10%
Contact Ratings
  • 2 A (@ 30 Vdc)
  • 0.6 A (@ 125 Vac)
Release/Actuation Time ~3 ms
Operating Temperature -40° to +70°C
Standards
  • Underwriters Laboratories (UL) listed product (E162021)
  • Canadian Underwriters Laboratories (CUL) listed product (5Z21)
Dimensions 22.4 x 13.9 x 4.1 cm (8.8 x 5.5 x 1.6 in.) including switches and mounts
Weight 635 g (1.4 lb)

Expected Life (contact closures)

Mechanical 108
Electrical
  • 5x105 (2 A at 30 Vdc)
  • 2x106 (1 A at 30 Vdc )

互換性

注意: 以下は代表的な互換性情報を示しています。互換性のある製品や互換性のない製品をすべて網羅したリストではありません。

Data Loggers

製品 互換性 注意
21X (リタイア)
CR10 (リタイア)
CR1000 (リタイア)
CR10X (リタイア)
CR200X (リタイア)
CR206X (リタイア)
CR211X (リタイア)
CR216X (リタイア)
CR23X (リタイア)
CR295X (リタイア)
CR3000 (リタイア)
CR500 (リタイア) The CR500 has only one control port capable of providing a control signal.
CR5000 (リタイア)
CR510 (リタイア) The CR510 has only one control port capable of providing a control signal.
CR800 (リタイア) The CR800 has only four control ports capable of providing a control signal.
CR850 (リタイア) The CR850 has only four control ports capable of providing a control signal.
CR9000 (リタイア)
CR9000X (リタイア)

Mounting Equipment

製品 互換性 注意
ENC10/12
ENC10/12R
ENC12/14
ENC14/16
ENC16/18
ENC24/30
ENC24/30S

互換性に関する追加情報

Data Logger Considerations

Each of the six relays is controlled by a data logger control port.

Cables

Cable(s) Used Number of Relays Controlled
One CABLE3CBL-L 1
One CABLE4CBL-L 2
One CABLE5CBL-L 3
Two CABLE3CBL-L 4
One CABLE3CBL-L and
one CABLE4CBL-L
5
Two CABLE4CBL-L 6

Power Considerations

The A6REL-12 consumes 30 mA per active LED. The A6REL-12 may be powered by the data logger power supply (see manual for considerations with 21X) or a separate 8.4 to 24 Vdc battery. The A6REL-12 must be powered by a Class 2 device (Campbell Scientific power supplies conform to this requirement).

Enclosure Considerations

The A6REL-12 requires a non-condensing environment; a Campbell Scientific enclosure is recommended. A6REL-12's with serial numbers 1445 and higher include mounting flanges with keyhole slots that attach to the backplate of an enclosure. Grommets and screws are provided.

A6REL-12s with serial numbers 1444 and lower require the 6281 bracket kit for attachment to the backplate of Campbell enclosures.

ドキュメント


よくある質問

A6REL-12に関するよくある質問の数: 1

  1. The following relay devices can be used with the CR800 and the CR850:

    • 7321
    • A6REL-12*
    • A21REL-12
    • LR4
    • SDM-CD8S
    • SDM-CD16AC
    • SDM-CD16ACA
    • SDM-CD16S

    The CR800 and the CR850 can also be used with a wide variety of third-party relay devices.

    *Because the CR800 and the CR850 only have four digital ports, they do not have the ability to switch all six of the relays on the A6REL-12.