RETIRED ›
This product is no longer available and has been replaced by: AVW200.
AVW100 Interface for Vibrating Wire Sensors
Services Available
Repair No
Calibration No
Free Support No

概要

The AVW100 is available as a replacement part or as needed for continuity or compatibility, but Campbell Scientific recommends the AVW200-series interfaces for all new applications. The AVW200 interfaces are much more accurate and feature a high degree of noise immunity for your vibrating wire measurements.

The AVW100 provides amplification and signal conditioning for the frequency signal of one vibrating wire or vibrating strip transducer. Compatible sensors include pressure, load, strain, or even vibrating wire temperature sensors. The recommended frequency range is 250 to 9900 Hz (up to 5000 Hz in the CR5000). It is similar in general design to our AVW1 and AVW4, but it is designed for use with frequencies that those interfaces do not support (i.e., 250 to 1000 Hz).

続きを読む

利点と特徴

  • Interfaces one vibrating strip/wire sensor to the data logger
  • Interfaces both temperature and frequency measurements from vibrating wire sensors
  • Supports a frequency sweep range of 250 to 9900 Hz
  • Can be used in conjunction with an AM16/32B or AM416 multiplexer

イメージ

詳細

The AVW100 is available as a replacement part or as needed for continuity or compatibility, but we recommend the AVW200-series interfaces for all new applications. The AVW200-series interfaces are much more accurate and feature a high degree of noise immunity for your vibrating wire measurements.

The AVW100 provides amplification and signal conditioning for vibrating wire pressure, load, strain, or temperature sensors. The recommended frequency range is 250 to 9900 Hz (up to 5000 Hz in the CR5000). It is similar in general design to our AVW1 and AVW4, but is designed for use with frequencies that those interfaces do not support (i.e., 250 to 1000 Hz).

仕様

Frequency Sweep Range 250 to 9900 Hz
Number of Vibrating Wire Sensors Measured One vibrating wire sensor connects to the AVW100. Additional sensors can be measured by using an AM16/32-series multiplexer.

互換性

注意: 以下は代表的な互換性情報を示しています。互換性のある製品や互換性のない製品をすべて網羅したリストではありません。

Data Loggers

製品 互換性 注意
21X (リタイア)
CR10 (リタイア)
CR1000 (リタイア)
CR1000X
CR10X (リタイア)
CR200X (リタイア)
CR206X (リタイア)
CR211X (リタイア)
CR216X (リタイア)
CR23X (リタイア)
CR295X (リタイア)
CR3000 (リタイア)
CR500 (リタイア)
CR5000 (リタイア)
CR510 (リタイア)
CR800 (リタイア)
CR850 (リタイア)
CR9000 (リタイア)
CR9000X (リタイア)

互換性に関する追加情報

Data Logger Considerations

Programming

Vibrating wire/strip transducers are measured by the VibratingWire Instruction in CRBasic, and by Instruction 28 (Vibrating Wire) in Edlog. The data logger produces a swept-frequency excitation, then measures a specified number of cycles of the sensor's resonant frequency.


よくある質問

AVW100に関するよくある質問の数: 3

すべて展開すべて折りたたむ

  1. The AVW1, AVW4, and AVW100 have a resolution of 0.1 Hz. Certifications of compliance for these items are not available.

  2. Both the P28 and P131 instructions will work with the AVW100. The AVW100 was designed for sensors with measurement frequencies below 1000 Hz, so it is the best choice if any part of the swept frequency of the transducer is below 1000 Hz. Compared to the P28 instruction, the P131 instruction has four additional user-configured parameters, which allow the user to fine tune the measurement; otherwise, the P28 and P131 instructions are identical.

  3. The AVW1 is able to detect frequencies ranging from 1000 to 9900 Hz; the AVW100 is able to detect frequencies ranging from 250 to 9900 Hz.

Privacy Policy Update