CS410-L Shaft Encoder
利用できるサービス

概要

The CS410 is a shaft encoder that measures water level for Campbell Scientific data acquisition systems. It connects directly to our data loggers; a QD1 interface is not required. All of our data loggers are compatible.

続きを読む

利点と特徴

  • Measures water level in stilling wells
  • Rugged enough for harsh environments
  • Low power consumption
  • Connects directly with our data loggers (no interface required)
  • Compatible with most Campbell Scientific data loggers

イメージ

詳細

The CS410 consists of a pulley attached to a float and counter-weight that rotates as water level rises or falls. When the pulley rotates, the CS410 sends two pulse strings to the data logger. The data logger records the pulse strings, and calculates water level by adding or subtracting the clockwise or counter clockwise movement to a running total. The encoder's resolution is 100 counts per shaft revolution, so a 1-foot circumference pulley has a resolution of 0.01 feet.

A complete measurement system requires a float, pulley, float tape or beaded float line, end hooks, appropriate-sized counter weight, and data logger. See the Ordering Information on the web page for products that are available from Campbell Scientific.

仕様

Operating Temperature Range -25° to +50°C (not responsive if water surface freezes)
Thread Count 24 per in.
Resolution 100 counts/revolution
Starting Torque < 0.125 inch-ounces
Power Supply 4 to 5.6 V
Current Drain 0.5 mA
Minimum Time between Input Transitions 0.75 ms
Output Pulse Width 0.25 ms (at 25°C)
Signal Magnitude 0 (low), supply voltage (high)
Shaft Outer Diameter 0.8 cm (0.3125 in.)
Dimensions 18 x 12.4 x 10 cm (7 x 4.875 x 4 in.)
Weight 0.82 kg (1.8 lb)

互換性

注意: 以下は代表的な互換性情報を示しています。互換性のある製品や互換性のない製品をすべて網羅したリストではありません。

Data Loggers

製品 互換性 注意
21X (リタイア)
CR10 (リタイア)
CR1000 (リタイア)
CR10X (リタイア)
CR200X (リタイア)
CR206X (リタイア)
CR211X (リタイア)
CR216X (リタイア)
CR23X (リタイア)
CR295X (リタイア)
CR3000 (リタイア)
CR500 (リタイア)
CR5000 (リタイア)
CR510 (リタイア)
CR800 (リタイア)
CR850 (リタイア)
CR9000 (リタイア)
CR9000X (リタイア)

互換性に関する追加情報

Data Logger Considerations

The CS410 is measured by two pulse count channels on the data logger; one channel counts "up" pulses, the other counts "down" pulses, and then water level is determined in the data logger. Although all of our data loggers are capable of measuring the CS410, the larger data loggers generally exceed application requirements because CS410 installations are typically remote and usually aren't measured with many other sensors.

ドキュメント

カタログ

マニュアル


よくある質問

CS410-Lに関するよくある質問の数: 3

すべて展開すべて折りたたむ

  1. すべてのセンサに異なるケーブル終端オプションがあるわけではありません。特定のセンサで利用可能なオプションは、センサ製品ページの注文情報エリアの 2 つの場所で確認できます。

    モデル番号
    ケーブル終端オプション リスト
    センサが –ET、–ETM、–LC、–LQ、または –QD バージョンで提供されている場合、そのオプションが利用可能かどうかはセンサモデル番号に反映されます。たとえば、034B は 034B-ET、034B-ETM、034B-LC、034B-LQ、および 034B-QD として提供されています。

    その他のすべてのケーブル終端オプション (利用可能な場合) は、センサ製品ページの注文情報エリアの「ケーブル終端オプション」の下にリストされています。たとえば、034B-L 風力発電セットは、034B-L 製品ページの注文情報エリアに示されているように、–CWS、–PT、および –PW オプションで提供されています。

    注意: 新しい製品が在庫に追加されると、通常は複数のモデル番号を作成するのではなく、1 つのセンサモデルの下に複数のケーブル終端オプションをリストします。たとえば、HC2S3-L には、HC2S3-LC モデルではなく、CS110 に接続するための –C ケーブル終端オプションがあります。

  2. Most Campbell Scientific sensors are available as an –L, which indicates a user-specified cable length. If a sensor is listed as an –LX model (where “X” is some other character), that sensor’s cable has a user-specified length, but it terminates with a specific connector for a unique system:

    • An –LC model has a user-specified cable length for connection to an ET107, CS110, or retired Metdata1.
    • An –LQ model has a user-specified cable length for connection to a RAWS-P weather station.

    If a sensor does not have an –L or other –LX designation after the main model number, the sensor has a set cable length. The cable length is listed at the end of the Description field in the product’s Ordering information. For example, the 034B-ET model has a description of “Met One Wind Set for ET Station, 67 inch Cable.” Products with a set cable length terminate, as a default, with pigtails.

    If a cable terminates with a special connector for a unique system, the end of the model number designates which system. For example, the 034B-ET model designates the sensor as a 034B for an ET107 system.

    • –ET models terminate with the connector for an ET107 weather station.
    • –ETM models terminate with the connector for an ET107 weather station, but they also include a special system mounting, which is often convenient when purchasing a replacement part.
    • –QD models terminate with the connector for a RAWS-F Quick Deployment Station.
    • –PW models terminate with the connector for a PWENC or pre-wired system.
  3. Many Campbell Scientific sensors are available with different cable termination options. These options include the following:

    • The –PT (–PT w/Tinned Wires) option is the default option and does not display on the product line as the other options do. The cable terminates in pigtails that connect directly to a data logger.
    • In the –C (–C w/ET/CS110 Connector) option, the cable terminates in a connector that attaches to a CS110 Electric Field Meter or an ET-series weather station.
    • In the –CWS (–CWS w/CWS900 Connector) option, the cable terminates in a connector that attaches to a CWS900-series interface. Connection to a CWS900-series interface allows the sensor to be used in a wireless sensor network.
    • In the –PW (–PW w/Pre-Wire Connector) option, the cable terminates in a connector that attaches to a prewired enclosure.
    • In the –RQ (–RQ w/RAWS Connector) option, the cable terminates in a connector that attaches to a RAWS-P Permanent Remote Automated Weather Station.

    Note: The availability of cable termination options varies by sensor. For example, sensors may have none, two, or several options to choose from. If a desired option is not listed for a specific sensor, contact Campbell Scientific for assistance.

Privacy Policy Update

We've updated our privacy policy.  詳細はこちら

Cookie Consent

Update your cookie preferences.  クッキーの設定を更新する