RETIRED ›
This product is no longer available.
SEN12512 EasyAG Water-Content Probe with SDI-12 Interface
Services Available

概要

Note: The SEN12512 is only available in a limited supply and will be discontinued after the supply is exhausted. 

The SEN12512 is an EasyAG probe with an SDI-12 interface and a 50-cm length. This probe provides water content profiles for cultivated soils of good tilth—commonly found in vegetable production areas. For stony soils where the average stone size is greater than 10 mm, use the EnviroSCAN probe.

続きを読む

利点と特徴

  • Multiple sensors at fixed depths
  • Built-in probe orientation and depth settings to increase sensor repeatability
  • Customized access tube increases sensor accuracy
  • Specially sealed to guarantee long-term operation
  • Probe and sensors are readily accessible and serviceable without destroying the site

イメージ

詳細

The SEN12512 includes several water content sensors that measure soil water at multiple depths. Around each sensor, the probe creates a high frequency electrical field that extends through the access tube into the soil. Electrical capacitance is then measured and soil water content is determined from those measurements.

Each water content sensor outputs an SDI-12 signal that our CR200(X)-series, CR800, CR850, CR1000, and CR3000 dataloggers can measure. This allows the probes to be integrated with a Campbell Scientific data logger or weather station. Integrating the probes into our data acquisition systems allows the data to be telemetered back to a field station or remote computer.

仕様

Sensor Measuring Principle High-frequency capacitance
Output SDI-12 version 1.2
Interface Measuring Principle 16 bit pulse count
Output Resolution 16 bit
Current Consumption
  • 250 µA (sleep)
  • 66 mA (standby)
  • 100 mA (sampling)
Water Content Reading Range 0 to ~65%
Temperature Effects ±3% (5° to 35°C)
Time to Read 1 Sensor 1.1 s
Sphere of Influence 99% of the reading is taken within a 10 cm radius from the outside of the access tube.
Sensors per Standard Probe 5
Operating Temperature Range 0° to 75°C
Sensor Diameter 2.65 cm (1.0 in.)
Access Tube Diameter 3.2 cm (1.3 in.)
Probe Length 50 cm (20 in.)

互換性

注意: 以下は代表的な互換性情報を示しています。互換性のある製品や互換性のない製品をすべて網羅したリストではありません。

Data Loggers

製品 互換性 注意
21X (リタイア)
CR10 (リタイア)
CR1000 (リタイア)
CR10X (リタイア)
CR200X (リタイア)
CR206X (リタイア)
CR211X (リタイア)
CR216X (リタイア)
CR23X (リタイア)
CR295X (リタイア)
CR3000 (リタイア)
CR500 (リタイア)
CR5000 (リタイア)
CR510 (リタイア)
CR800 (リタイア)
CR850 (リタイア)
CR9000 (リタイア)
CR9000X (リタイア)

よくある質問

SEN12512に関するよくある質問の数: 2

  1. To protect itself, the interface will switch off when the supply voltage is above or below these operating voltages:

    • Series 1: 9.6 to 20 Vdc (regulated)
    • Series 2: 4.5 to 15 Vdc (regulated)

下記の製品は置き換えられました

Privacy Policy Update

We've updated our privacy policy.  詳細はこちら

Cookie Consent

Update your cookie preferences.  クッキーの設定を更新する