RETIRED ›
This product is no longer available.
ENVIROSCAN Water-Content-Profile Probe with SDI-12 Interface
利用できるサービス
修理 非対応
キャリブレーション 非対応
フリーサポート 非対応

概要

The EnviroSCAN probe provides soil-water-content profiles for irrigation scheduling or other water movement systems. The measurement range is oven dry to saturation. The probes measure soil moisture at multiple depths and are easy to install. Tools offered by Campbell Scientific allow the probes to be installed with minimal soil disturbance. EnviroSCAN is recommended for higher accuracy research measurements, measurements deeper than 80 cm, or stony soils. It is customizable by adding sensors at user-specified depths.

続きを読む

イメージ

詳細

The EnviroSMART probe has been renamed EnviroSCAN.

The EnviroSCAN includes several water content sensors that measure soil water at multiple depths. Around each sensor, the probe creates a high frequency electrical field that extends through the access tube into the soil. Electrical capacitance is then measured and soil water content is determined from those measurements.

Each water content sensor outputs an SDI-12 signal that our CR200(X)-series, CR800, CR850, CR1000, and CR3000 dataloggers can measure. This allows the probes to be integrated with a Campbell Scientific data logger or weather station. Integrating the probes into our data acquisition systems allows the data to be telemetered back to a field station or remote computer.

EnviroSCAN is customized for individual applications by adding sensors at user-specified measurement depths. The maximum measurement depth of the standard configuration is 2 m (6 ft); deeper measurements are possible with special provisions.

仕様

Maximum Sensors per Standard Probe 16
Sensor Measuring Principle High-frequency capacitance
Output SDI-12 version 1.2
Total Current Consumption (per sensor)
  • 250 µA (sleep)
  • 66 mA (standby)
  • 100 mA (sampling)
TriSCAN Current Consumption 130 mA (sampling)
Water Content Reading Range 0 to ~65%
Temperature Effects ±3% (5° to 35°C)
Time to Read 1 Sensor 1.1 s
Sphere of Influence 99% of the reading is taken within a 10 cm radius from the outside of the access tube.
Operating Temperature Range -20° to +75°C
Sensor Diameter 5.05 cm (2.0 in.)
Access Tube Diameter 5.65 cm (2.2 in.)
Probe Length 0.5, 1.0, 1.5, or 2.0 m (1.6, 3.3, 4.9, or 6.6 ft)

互換性

注意: 以下は代表的な互換性情報を示しています。互換性のある製品や互換性のない製品をすべて網羅したリストではありません。

Data Loggers

製品 互換性 注意
21X (リタイア)
CR10 (リタイア)
CR1000 (リタイア)
CR10X (リタイア)
CR200X (リタイア)
CR206X (リタイア)
CR211X (リタイア)
CR216X (リタイア)
CR23X (リタイア)
CR295X (リタイア)
CR3000 (リタイア)
CR500 (リタイア)
CR5000 (リタイア)
CR510 (リタイア)
CR800 (リタイア)
CR850 (リタイア)
CR9000 (リタイア)
CR9000X (リタイア)

よくある質問

ENVIROSCANに関するよくある質問の数: 2

  1. To protect itself, the interface will switch off when the supply voltage is above or below these operating voltages:

    • Series 1: 9.6 to 20 Vdc (regulated)
    • Series 2: 4.5 to 15 Vdc (regulated)

Privacy Policy Update

We've updated our privacy policy.  詳細はこちら

Cookie Consent

Update your cookie preferences.  クッキーの設定を更新する