NL115 Ethernet Interface and CompactFlash Module
利用できるサービス
修理 対応
キャリブレーション 非対応
フリーサポート 対応

概要

Campbell Scientific’s NL115 enables 10baseT Ethernet communications and stores data on a removable CompactFlash® card. This small, rugged communication device connects to the 40-pin peripheral port on a CR1000 or CR3000 datalogger.

続きを読む

利点と特徴

  • Provides Ethernet communications and additional data storage for a CR1000 or CR3000 datalogger
  • Ethernet connection allows for data logger communications over a local area network or the Internet via TCP/IP
  • Removable CompactFlash cards can provide long-term data storage
  • Small, light-weight CF cards fit in your pocket for easy transport between the data logger and PC

イメージ

詳細

The NL115 allows the data logger to communicate over a local network or a dedicated Internet connection via TCP/IP. A 10baseT Ethernet straight through cable is used when the cable is run from a hub to the NL115. A 10baseT Ethernet crossover cable is used if the cable is run directly from the computer to the NL115.

The NL115/CF card combination can be used to expand the data logger's memory, transport data/programs from the field site(s) to the office, and upload power up functions. One Type I or Type II CompactFlash (CF) card fits into the NL115’s card slot.

Only industrial-grade CF cards should be used with our products. Although consumer-grade cards cost less than industrial-grade cards, the consumer-grade cards are more susceptible to failure resulting in both the loss of the card and its stored data. Industrial-grade cards also function over wider temperature ranges and have longer life spans than consumer-grade cards.

Data stored on the card can be retrieved either by removing the card and carrying it to a computer or through a communications link with the data logger. The computer can read the CF card either with the computer’s PCMCIA slot and the CF1 adapter or the computer’s USB port and the 17752 Reader/Writer.

CardConvert is used to convert and save binary data from a CompactFlash® card. CardConvert is included in our PC200W, PC400, LoggerNet, and RTDAQ datalogger support software.

仕様

Power Requirements 12 V supplied through the data logger’s peripheral port
Ethernet Speed 10Base-T (10 Mbps), half-duplex
Typical Access Speed 200 to 400 kbits s-1
Memory Configuration User selectable; ring (default) or fill-and-stop
CF Card Requirements Industrial-grade
Data Logger Operating System (OS) The CR1000 OS must be OS 9 or later. Both the CR1000 and CR3000 need OS 25 or later to read cards with more than 2 GB of storage.
Typical Current Drain
  • 19 mA (CR1000 with NL115, no Ethernet cable attached, not actively communicating over Ethernet nor accessing the CF card)
  • 20 mA (CR1000 with NL115, Ethernet cable attached)
  • 20 mA (CR1000 with NL115, Ethernet cable attached and communicating over Ethernet)
  • 43 mA (CR1000 with NL115 communicating over Ethernet and accessing CF card)
  • 2 mA (CR1000 with NL115; Ethernet port has been put to sleep using the IPNetPower() CRBasic instruction.)
  • Add 1 mA to current drain if red or green Status LED is continuously on.
  • Add 2 mA to current drain if orange Status LED is continuously on.
Dimensions
  • 10.2 x 8.9 x 6.4 cm (4.0 x 3.5 x 2.5 in.)
  • 25.2 x 10.2 x 7.1 cm (9.9 x 4.0 x 2.8 in.) for CR1000 with NL115 attached
Weight 154 g (5.4 oz)

EMI and ESD Protection

European Standards Meets requirements for a class A device under European Standards.
Application of Council Directive(s) 89/336/EEC as amended by 89/336/EEC and 93/68/EEC
Standards to Which Conformity Is Declared EN55022-1; 1995 and EN50082-1: 1992

Software Requirements

LoggerNet Version 3.2 or later
PC400 Version 1.3 or later
DevConfig Version 1.5 or later

互換性

注意: 以下は代表的な互換性情報を示しています。互換性のある製品や互換性のない製品をすべて網羅したリストではありません。

Data Loggers

製品 互換性 注意
CR1000 (リタイア)
CR200X (リタイア)
CR206X (リタイア)
CR211X (リタイア)
CR216X (リタイア)
CR295X (リタイア)
CR3000 (リタイア)
CR5000 (リタイア)
CR800 (リタイア)
CR850 (リタイア)
CR9000X (リタイア)

Mounting Equipment

製品 互換性 注意
ENC10/12
ENC10/12R CR1000またはCR3000に取り付け
ENC12/14 CR1000に取り付け
ENC14/16 CR1000またはCR3000に取り付け
ENC16/18 Attached to a CR1000 or CR3000
ENC24/30 Attached to a CR1000 or CR3000
ENC24/30S Attached to a CR1000 or CR3000

互換性に関する追加情報

CompactFlash (CF) Cards

Campbell Scientific offers and recommends several CF cards (see Ordering tab). These cards have passed Campbell Scientific's ESD testing and operate properly with our data loggers.

Only industrial-grade CF card should be used with our products. Although consumer-grade cards cost less than industrial-grade cards, the consumer-grade cards are more susceptible to failure resulting in both the loss of the card and its stored data. Industrial-grade cards also function over wider temperature ranges and have longer life spans than consumer-grade cards.

Software Requirements

The NL115 is set up using the Device Configuration utility (DevConfig). The NL115 requires LoggerNet 3.2 or later, PC400 1.3 or later, and DevConfig 1.5 or later.

Data Logger Considerations

The NL115 fastens onto the data logger's 40-pin peripheral port. This means that the NL115 is only compatible with the CR1000 and CR3000. It is NOT compatible with the CR800, CR850, CR200X, CR5000, or CR9000X dataloggers.

To read cards with more than 2 GB of storage, the data logger operating system must be OS 25 or later.


よくある質問

NL115に関するよくある質問の数: 31

すべて展開すべて折りたたむ

  1. No. The CR800 and CR850 do not have the necessary peripheral port to connect to an NL115.

  2. The file on the card is open until the program is stopped or the button on the device is pressed.

  3. The NL115 isn’t configurable for an IP address. The IP address is set in the data logger using the Device Configuration Utility.

  4. If the CardOut() or TableFile() instructions are configured as fill and stop, the data logger will stop writing data to the CompactFlash cards after they are full.

  5. When the CardOut() instruction or the TableFile() with TFOption 64 instruction is used, the data table is saved to both the data logger’s internal memory and the card.

  6. The CFM100 or NL115 is detected during the data logger boot-up cycle, that is, when it is powered on. Disconnect or connect the CFM100 or NL115 to a data logger only after power to the data logger has been disconnected. 

  7. Campbell Scientific always recommends using CF cards carried by Campbell Scientific. Although another CF card might fit and work with a CFM100 or NL115, the CF card might not be rated for the same temperature range as the CFM100 or NL115. In addition, another CF card might not have the same electrostatic discharge (ESD) immunity as the cards tested and carried by Campbell Scientific. For more detail on CF cards, see the “CF Card Information” application note.

ケーススタディ

米国気候参照ネットワーク
1990 年代後半、世界の気候条件の変化に対する懸念が高まる中、米国にはデータ収集を行う何千もの気象観測所がありました。しかし、観測所の多くは設置場所や管理が一貫しておらず、老朽化し​​ており、信頼性を失う危険があることが判明しました。これらの観測所の中で最も優れたものは、Historical Climate Network と呼ばれ、1930 年代までさかのぼって優れたデータを収集していました。 気候変動の潜在的影響を評価する人々に信頼できる情報を提供するには、気温測定ステーションのネットワークを改善する必要がありました。膨大な量の過去の気候観測データを検証する必要があり、将来にわたって継続的かつ均一な気象測定を提供するプログラムが必要でした。 国の既存の観測能力を安定させ、長期にわたって気候観測プログラムを開発、実施、運用する任務は、米国海洋大気庁 (NOAA) とその大気乱流拡散部門 (ATDD) に与えられました。任務には、50 年以上にわたって一貫した測定が期待できる高品質の気象観測所の新しいネットワークを構築することが含まれていました。また、同局は、既存の歴史的気候ネットワークのデータと新しい観測所のデータを比較して、歴史的データが信頼できることを確認する必要がありました。目標は、気候変動を検出するために、1930 年代から 21 世紀まで信頼できる継続的なデータ ストリームを提供することでした。 NOAA......続きを読む
アラスカ: 渦相関
科学者や土地利用管理者は、炭素吸収における森林地帯の重要性を長い間認識してきました。研究と国際政策は主に熱帯林と生息地に焦点が当てられてきました。熱帯林と生息地は成長が早く、頻繁な伐採の影響を受けやすいためです。しかし最近では、安定的に炭素を吸収して貯蔵できる生息地が地球全体の炭素状況の重要な部分であると認識されるようになり、寒帯地域などの冷涼な気候の景観に研究の焦点が当てられるようになりました。これらの地域では成熟した森林と気温によって分解速度が制限されるため、気候変動がこれらの景観を変える潜在的な影響により、景観をより完全に理解するための取り組みが強化されています。 アラスカ大学フェアバンクス校の研究者らは、米国地質調査所の資金援助を受け、国立科学財団の長期生態学研究ネットワークの一部であるボナンザ クリーク実験林内の 3 か所の環境モニタリング サイトに機器を設置しました。これらのサイトは、微気候の違いによって決まる陸上北方景観の重要な生息地を代表する永久凍土の劣化の年代順に位置しています。3 つのサイトには、クロトウヒ林 (クロトウヒの森がそのまま残っている安定した永久凍土の地域)、永久凍土が下にある地表の氷が溶けて樹木がかなり枯死している活発なサーモカルスト サイト、活動層の深さが深く安定した樹木のない湿原サイトが含まれます。 このプロジェクトの目標は、北極圏の気候システムにおける地表、大気、海洋間の重要なつながりとフィードバックである炭素、水、エネルギーのフラックスを年間を通じて継続的に測定することです。これまで、北極圏では環境条件が厳しく、遠隔地へのアクセスが困難なため、このような研究はほとんど行われていません。冬季に太陽光発電が限られ、風力発電が実行可能な選択肢ではない場所で継続的に監視するには、電力要件が極めて低く、リモート システム診断機能を備えた堅牢なセンサーを選択する必要があります。 Bonanza Creek サイトで、渦相関フラックス測定に Campbell Scientific の EC150......続きを読む

記事とプレスリリース


以下に記載

下記製品のその他アクセサリです:

Privacy Policy Update

We've updated our privacy policy.  詳細はこちら

Cookie Consent

Update your cookie preferences.  クッキーの設定を更新する