The SVP48 is a DIN rail bracket that holds up to 22 of the 8206 surge protectors. This bracket mounts to the backplate of our standard enclosures. The 8206 protects a data logger against electrical transients conducted along the sensor cables.
続きを読むThe SVP48 DIN rail bracket holds up to 22 of the 8206 surge protectors. Each 8206 is ordered as a separate line item. The DIN rail attaches to an enclosure backplate via two mounting holes that are spaced 6 in. (15.2 cm) apart, center-to-center.
The 8206 protects a data logger against electrical transients conducted along the sensor cables. The surge protectors trigger at 110 Vac or 156 Vdc; voltages exceeding those levels are shunted to ground. The surge protectors are rated for 125 Vac or 177 Vdc. The voltage limitation is 650 V at 1 kV/microsecond. Each surge protector protects one signal conductor and provides a termination for one shield wire.
注意: 以下は代表的な互換性情報を示しています。互換性のある製品や互換性のない製品をすべて網羅したリストではありません。
SVP48に関するよくある質問の数: 1
Yes. There is surge protection built into the sensor electronics. The sensor survives a surge of 2 kV at 42 ohm line-to-ground on digital I/O and 2 kV at 12 ohm line-to-ground on power. It also survives a surge of 2 kV at 2 ohm line-to-ground on the rods.
If additional surge protection is required, consider using the SVP100 Surge Voltage Protector DIN Rail with Mounting Hardware.