RETIRED ›
This product is no longer available and has been replaced by: TX321.
TGT1 GOES Transmitter
利用できるサービス
修理 非対応
キャリブレーション 非対応
フリーサポート 非対応

概要

The TGT1 interfaced directly with our data logger's CS I/O port. This transmitter supported U.S. transmission channels, and featured an output level of +40 dBm (10 Watts) and a transmission rate of 100 bits/second. Typically, 118 data points were transmitted during a 1-minute transmit window.

続きを読む

イメージ

詳細

The TGT1 had an average quiescent current drain of 9 mA and an active current drain of 2200 mA. The transmitter's forward/reflected power could be measured by the data logger. A large reflected power indicated a possible problem in the equipment and Campbell Scientific should be contacted.

Power Supply
Typical power supply was a BP12 12-Ahr or BP24 24-Ahr battery, CH12R regulator, and a 10-watt solar panel. A user-supplied deep-cycle rechargeable battery was used when it was difficult to replace the batteries or the system's power requirements were large. The deep-cycle rechargeable battery should have at least a 60 Ahr capacity, and be trickle-charged with an 20 W solar panel.

User-supplied Equipment

  • Phone modem with MNP level 4 error correction
  • Computer with user-supplied communication software (e.g., PROCOMMPlus, Crosstalk; see NESDIS for requirements)

The TGT1 was replaced by the SAT HDR GOES, which was replaced with the TX312.


互換性

注意: 以下は代表的な互換性情報を示しています。互換性のある製品や互換性のない製品をすべて網羅したリストではありません。

Data Loggers

製品 互換性 注意
21X (リタイア) Requires Telonics PROM.
CR10 (リタイア) Requires Telonics PROM.
CR1000 (リタイア)
CR10X (リタイア)
CR200 (リタイア)
CR206 (リタイア)
CR210 (リタイア)
CR211 (リタイア)
CR215 (リタイア)
CR216 (リタイア)
CR23X (リタイア) Requires OSX 1.7 or greater.
CR295 (リタイア)
CR3000 (リタイア)
CR500 (リタイア)
CR5000 (リタイア)
CR510 (リタイア)
CR800 (リタイア)
CR850 (リタイア)
CR9000 (リタイア)
CR9000X (リタイア)

互換性に関する追加情報

The TGT1 is programmed with the star pound (*#) mode and Instruction 99 (CR10, 21X) or Instruction 120 (CR23X, CR10X, CR510, CR500). The star pound (*#) mode establishes and edits parameters, displays status information, and performs test transmissions. The *# mode is accessed through the data logger's keyboard. Use of the CR10X, CR10, CR510, or CR500 requires the CR10KD keyboard display. Instruction 99 or 120 automatically synchronizes the data logger's clock with the transmitter's, transfers the data logger's data to the transmitter's buffer, and designates an input location for the forward/reflected power measurement.

Privacy Policy Update

We've updated our privacy policy.  詳細はこちら

Cookie Consent

Update your cookie preferences.  クッキーの設定を更新する