RETIRED ›
This product is no longer available and has been replaced by: CR300,CR310.
CR215 Datalogger with 2.4 GHz Spread Spectrum Radio
利用できるサービス
修理 非対応
キャリブレーション 非対応
フリーサポート 非対応

概要

The CR215 was a small, low-cost data logger with an internal 2.4 GHz spread spectrum radio. It was replaced by the CR216, has improved communication capability. The CR215 can be used within a CR216(X) network, but the CR216(X) needs to be in the transparent mode. Contact one of our application engineers for details.

利点と特徴

  • On-board 12 Vdc lead acid battery charger

イメージ


仕様

A/D Converter 12 bit
Maximum Scan Rate Once per second
Single-Ended Analog Channels 5, individually configured
Analog Voltage Range 0 to +2500 mV
Measurement Resolution 0.6 mV
Excitation Channels 2 (programmable for either +2.5 or +5 volts)
Switched Battery Port 1
Pulse Count Channels 2
Control Ports 2
Battery Voltage Range 7 to 16 Vdc
Communications RS-232

互換性

注意: 以下は代表的な互換性情報を示しています。互換性のある製品や互換性のない製品をすべて網羅したリストではありません。

Sensors

製品 互換性 注意
014A-L
03002-L
034B-L
05103-45-L (リタイア)
05103-L
05106-L (リタイア)
05305-L
107
108
109
109SS-L
110PV-L (リタイア)
237-L (リタイア)
255-100
27106T-L
43347-L
52202-L
CMP11-L (リタイア)
CMP6-L (リタイア)
CS100
CS106
CS15-L (リタイア)
CS215-L (リタイア)
CS300-L (リタイア)
CS410-L (リタイア)
CS431-L (リタイア)
CS450-L (リタイア)
CS455-L (リタイア)
CS460-L (リタイア)
CS470 (リタイア)
CS471 (リタイア)
CS475A-L
CS475-L (リタイア)
CS511-L
CS525-L (リタイア)
CS547A-L
CS616
CS625 (リタイア)
CS650
CS700H-L
CS700-L
CSAT3 (リタイア)
CSIM11-L
CSIM11-ORP-L
ENVIROSCAN (リタイア)
HMP45C-L (リタイア)
HMP60-L
LI190SB-L (リタイア)
LI200X-L (リタイア)
LWS
OBS-3+ (リタイア)
OBS300 (リタイア)
SEN12512 (リタイア)
SR50A-L (リタイア)
TB4-L
TB4MM-L
TE525-L
TE525MM-L
TE525WS-L
WINDSONIC1-L
WINDSONIC4-L
WXT520 (リタイア)

Software

製品 互換性 注意
LoggerNet Version 2.1 or higher
PC200W (リタイア)
PC400 Version 1.0 or higher
PCONNECT (リタイア) Version 3.0 or higher
PCONNECTCE (リタイア) Version 2.0 or higher
Short Cut
VISUALWEATHER Version 2 or higher

互換性に関する追加情報

Communications

The CR215's internal spread spectrum radio can transmit data to other CR215 loggers or RF415 radios. It can also communicate with CR216(X) loggers, RF416 radios, or RF432 radios if they are set to the transparent mode. Certain CR215 settings must match the radio's settings for communications between the data logger and radio to be successful. The factory default settings of these devices might not match; therefore, they may need to be reconfigured before communications can take place. 

The CR215 can communicate with a PC via direct connect, NL100 Ethernet interface, MD485 multidrop modem, and digital cellular modems. Data can be viewed on the CD295 DataView II display, Archer-PCon Field PC, or a user-supplied PDA (PConnect or PConnectCE software required).

Measurement & Control Peripherals

The CR215 is not compatible with SDM devices and multiplexers.

Sensors

The CR215 can measure a variety of sensors including SDI-12 sensors and 4 to 20 mA sensors. It cannot make differential measurements and is not compatible with the freezing-rain/ice, fuel moisture/temperature, geographic position, present weather, soil heat flux, soil matric water potential, and strain sensors listed on our price lists.

Enclosures

Applications with minimal power requirements can use the ENC200 enclosure to house the data logger and the #16869 sealed rechargeable battery. The ENC200 cannot house a barometer or a battery that is larger than the #16869. However, an ENC10/12 or ENC12/14 enclosure is adequate for most CR215-based systems.

Power Supplies

The CR215 uses an external power supply and has a built-in regulator. When connected to the on-board charging circuit, the sealed rechargeable battery should be 7 Ahr or smaller. Using larger batteries with the data logger's built-in charger may result in excessive PC board heating. This is especially a concern when the battery is deeply discharged or failing with a shorted cell. Campbell Scientific also recommends that solar panels be 10 W or less and wall chargers be 1 A or smaller.

ドキュメント

ダウンロード

Device Configuration Utility v.2.31 (47.0 MB) 18-12-2024

A software utility used to download operating systems and set up Campbell Scientific hardware. Also will update PakBus Graph and the Network Planner if they have been installed previously by another Campbell Scientific software package.

Supported Operating Systems:

Windows 11 or 10 (Both 32 and 64 bit)

更新履歴をみる

CR200 MODBUS OS v.10 (1.97 MB) 08-09-2010

Special operating system that supports ModBus communication and SDI-12 sensors .  Also included is the Compiler and CRBasic Editor support files for the CR2xx dataloggers.

Use of this file will update the datalogger compiler and CRBasic Editor support files.

Note: Not to be used with the CR200X series.

Includes: MODBUS Instructions, SDI12Sensor, WindVector
Excludes: GOES Instructions, SerialInput, ETO, SendData, & LoggerIdentify


CR200 Serial Input OS v.10 (1.97 MB) 08-09-2010

Special operating system that supports serial sensors, SDI-12 sensors, and sending data to another PakBus device.  Also included is the Compiler and CRBasic Editor support files for the CR2xx dataloggers.

Use of this file will update the datalogger compiler and CRBasic Editor support files.

Includes: SerialInput, SendData, SDI12Sensor, WindVector
Excludes: GOES Instructions, ETo, MODBUS Instructions, LoggerIdentify


Short Cut v.4.6 (32.6 MB) 02-10-2024

Short Cut creates simple programs for our CR200-series, CR300-series, CR510, CR500, CR10(X), 21X, CR23X, CR6, CR800, CR1000(X), CR1000Xe, CR3000, CR5000, CR9000X and GRANITE dataloggers. Both mixed array and table data operating systems are supported. Short Cut also supports our ET106, ET107 and MetData1 weather stations. The newest version includes the latest sensor files.

更新履歴をみる

CR200 Default OS v.10 (1.97 MB) 08-09-2010

Default operating system loaded into the datalogger at the factory.  Also included is the Compiler and CRBasic Editor support files for the CR2xx dataloggers.

Use of this file will update the datalogger compiler and CRBasic Editor support files.

Includes: ETo, WindVector, LoggerIdentify
Excludes: GOES Instructions, SDI12Sensor, SerialInput, MODBUS Instructions, SendData

更新履歴をみる

よくある質問

CR215に関するよくある質問の数: 2

  1. The CR200X-series and the retired CR200-series dataloggers are NOT compatible with SDMs or multiplexers. If more channels are needed or may be needed in the future, consider purchasing a CR800, CR850, or CR1000 instead.

  2. A practical maximum is to connect one multiplexer per every two control terminals on the data logger. Control terminals can be shared between multiplexers to increase the number of connected multiplexers. Sharing terminals, however, requires more complex wiring and programming. Users who would like to connect more than one multiplexer per every two control terminals are advised to contact a sales or support engineer at Campbell Scientific for assistance.

Privacy Policy Update

We've updated our privacy policy.  詳細はこちら

Cookie Consent

Update your cookie preferences.  クッキーの設定を更新する