温湿度センサ / HMP45C-L
RETIRED ›
This product is no longer available and has been replaced by: EE181-L.
HMP45C-L Temperature and Relative Humidity Probe
利用できるサービス
修理 非対応
キャリブレーション 対応
フリーサポート 非対応

概要

The HMP45C is a rugged, accurate temperature and relative humidity probe. It measures relative humidity over the range of 0 to 100% RH and temperature over the range of -40° to +60°C. This probe is suitable for long-term, unattended monitoring, and is compatible with all Campbell Scientific data loggers.

続きを読む

利点と特徴

  • Well-suited for long-term, unattended applications
  • Accurate and rugged
  • Mounts to a tripod or tower mast, crossarm, or user-supplied pole
  • 13367 Sensor Head available to facilitate recalibration
  • Compatible with most Campbell Scientific data loggers

イメージ

詳細

The HMP45C probe uses a HUMICAP capacitive polymer H chip to measure relative humidity and a PRT to measure temperature. Yearly HMP45C recalibrations are recommended.

To reduce the current drain, power can be supplied to the HMP45C only during measurement when the sensor is connected to the data logger’s switched 12 V terminal. Data loggers that do not have a switched 12 V terminal, such as the CR510 or CR7, can use the SW12V switched 12 V device to switch power to the sensor only during measurement.

仕様

Supply Voltage 12 Vdc nominal (typically powered by data logger)
Current Drain ≤ 4 mA (active)
Cable Diameter 0.8 cm (0.3 in.)
Sensor Diameter 2.5 cm (1 in.)
Sensor Length 25.4 cm (10 in.)
Weight 0.27 kg (0.6 lb)

Relative Humidity

Sensor Vaisala’s HUMICAP H-chip
Measurement Range 0.8% to 100% RH (non-condensing)
Output Signal Range 0.008 to 1 Vdc
Accuracy at 20°C (against factory reference) ±1% RH
Accuracy at 20°C (field-calibrated against references)
  • ±2% (0% to 90% RH)
  • ±3% (90% to 100% RH)
Temperature Dependence ±0.05% RH/°C
Long-Term Stability Typically, better than 1% RH per year
Response Time 15 s with membrane filter (at 20°C, 90% response)
Settling Time 500 ms

Temperature

Temperature Sensor 1000 ohm Platinum Resistance Thermometer
Measurement Range -39.2° to +60°C
Output Signal Range 0.008 to 1.0 V
Accuracy at -40°C ±0.5°C
Accuracy at -20°C ±0.4°C
Accuracy at 0°C ±0.3°C
Accuracy at 20°C ±0.2°C
Accuracy at 40°C ±0.3°C
Accuracy at 60°C ±0.4°C

互換性

注意: 以下は代表的な互換性情報を示しています。互換性のある製品や互換性のない製品をすべて網羅したリストではありません。

Data Loggers

製品 互換性 注意
21X (リタイア)
CR10 (リタイア)
CR1000 (リタイア)
CR10X (リタイア)
CR200X (リタイア)
CR206X (リタイア)
CR211X (リタイア)
CR216X (リタイア)
CR23X (リタイア)
CR295X (リタイア)
CR3000 (リタイア)
CR500 (リタイア)
CR5000 (リタイア)
CR510 (リタイア)
CR800 (リタイア)
CR850 (リタイア)
CR9000 (リタイア)
CR9000X (リタイア)

互換性に関する追加情報

Mounting

The HMP45C should be housed in a 41003-5 10-plate naturally-aspirated solar radiation shield. The 27251 hex plug is required to mount the HMP45C in the 41003-5. At one time, this hex plug was shipped with the radiation shield but it no longer is. The41003-5 mounts to a tripod or tower mast, crossarm, or user-supplied pole.


よくある質問

HMP45C-Lに関するよくある質問の数: 1

  1. The HMP60-L (with the Campbell Scientific cable) cannot be used with the 41003-5 10-Plate Radiation Shield without the use of additional hardware. For more information, refer to the Compatibility information on the HMP60-L product page. The standard radiation shield for the HMP60-L is the 41303-5A.

ケーススタディ

Texas: Water Conservation
The city of Frisco, Texas, sits in an area that experienced severe drought from about......続きを読む
Spain: Oil Pier Met-Ocean Monitoring Station
Pont del Petroli was built in the 1960s to enable the transfer of oil from......続きを読む
Peru: High-Elevation Weather on Glaciers
Currently, the Andean tropical glaciers are in an accelerated process of retreat. These glaciers are......続きを読む
Washington: AgWeatherNet
Washington State University’s AgWeatherNet (AWN) is a large automated network composed almost entirely of Campbell......続きを読む
Alaska: Eddy Covariance
Scientists and land-use managers have long recognized the importance of forest lands for their role......続きを読む
Egypt: Preserving King Tut's Tomb
In 1922, when the intact tomb of Tutankhamen was discovered in Egypt's Valley of the......続きを読む
West Texas Mesonet
The West Texas Mesonet (WTM) project was initiated by Texas Tech University in 1999 to......続きを読む
Israel: Marine Meteorology on the Red Sea
The meteorological stations at the Interuniversity Institute for Marine Sciences at Eilat (IUI) in Israel......続きを読む

Privacy Policy Update

We've updated our privacy policy.  詳細はこちら

Cookie Consent

Update your cookie preferences.  クッキーの設定を更新する