温湿度センサ / HMP50-L
RETIRED ›
This product is no longer available and has been replaced by: HMP60-L.
HMP50-L Temperature and Relative Humidity Sensor
Services Available
Repair No
Calibration No
Free Support No

概要

The HMP50 measures both temperature and relative humidity and is suitable for long-term, unattended monitoring. The humidity component features a field-replaceable chip, which eliminates downtime typically required for the recalibration process. The HMP50 is compatible with all Campbell Scientific data loggers.

続きを読む

利点と特徴

  • Field-replaceable humidity chip eliminates recalibration down time
  • Can be mounted to a tower/tripod mast or crossarm

イメージ

詳細

The HMP50 measures temperature with a 1000 Ohm platinum resistance thermometer (PRT) and relative humidity (RH) with a 50Y Intercap capacitive chip. The chip is field-replaceable, which eliminates the downtime typically required for the recalibration process. This temperature and RH sensor is compatible with all Campbell Scientific data loggers.

The HMP50 should be housed in a solar radiation shield—typically the 41303-5A. The 41303-5A 6-plate naturally aspirated shield attaches to a mast, crossarm, or tower leg.

仕様

Supply Voltage 7 to 28 Vdc (typically powered by data logger’s 12 V supply)
Current Consumption 2 mA (typical)
Housing Material Chrome-coated aluminum and chrome-coated ABS plastic
Operating Temperature Range -40° to +60°C
Diameter 1.2 cm (0.47 in.)
Length 7.1 cm (2.8 in.)
Weight 0.05 kg (0.1 lb) with 1.83-m (6-ft) cable

Relative Humidity

Sensor Vaisala’s INTERCAP capacitive chip
Measurement Range 0 to 98% RH (non-condensing)
Accuracy
  • ±3% (0% to 90% range)
  • ±5% (90% to 98% range)
Temperature Dependence See graph in product brochure.

Temperature

Temperature Sensor 1000 ohm Platinum Resistance Thermometer
Measurement Range -40° to +60°C
Accuracy See graph in product brochure.

互換性

注意: 以下は代表的な互換性情報を示しています。互換性のある製品や互換性のない製品をすべて網羅したリストではありません。

Data Loggers

製品 互換性 注意
21X (リタイア)
CR10 (リタイア)
CR1000 (リタイア)
CR10X (リタイア)
CR200X (リタイア)
CR206X (リタイア)
CR211X (リタイア)
CR216X (リタイア)
CR23X (リタイア)
CR295X (リタイア)
CR3000 (リタイア)
CR500 (リタイア)
CR5000 (リタイア)
CR510 (リタイア)
CR800 (リタイア)
CR850 (リタイア)
CR9000 (リタイア)
CR9000X (リタイア)

互換性に関する追加情報

Mounting

The HMP50 is typically housed in a 41303-5A 6-plate naturally aspirated shield.

It may also be housed in a 41003-5 10-plate shield if additional hardware is used. A 41322 Adapter Plate allows the HMP50 to be mounted in the lower part of the 41003-5 10-plate shield. Alternatively, a 41381 extension tube and the 6637 split nut plug can be used to mount the HMP50 in a higher part of the 41003-5; the #41381 cable is also required.

Both the 41303-5A and the 41003-5 attach to a crossarm, mast, or user-supplied pipe with a 1.0-in. to 2.1-in. outer diameter.

ケーススタディ

South Africa: Solar Prospecting
Historically, the South African energy sector had been monopolized by a single state-owned utility company......続きを読む
District of Columbia: Solar Decathlon
The Solar Decathlon takes place every other year on the National Mall in Washington, D.C.......続きを読む
Israel: Marine Meteorology on the Red Sea
The meteorological stations at the Interuniversity Institute for Marine Sciences at Eilat (IUI) in Israel......続きを読む
Texas: College Weather Station
The Austin College Weather Station (ACWX) is located on Austin College's Sneed Environmental Research Area,......続きを読む

記事とプレスリリース

Privacy Policy Update

We've updated our privacy policy.  詳細はこちら

Cookie Consent

Update your cookie preferences.  クッキーの設定を更新する