衛星通信 / IRIDIUM9522B
RETIRED ›
This product is no longer available.
IRIDIUM9522B Satellite Modem and Interface Kit
利用できるサービス
修理 非対応
キャリブレーション 非対応
フリーサポート 対応

概要

The IRIDIUM9522B is a packaged solution for adding globally available two-way Iridium satellite communications to a remote station. Using the Iridium network to provide reliable end-to-end serial connectivity, the IRIDIUM9522B package makes it easy to connect to a remote station with Campbell Scientific's LoggerNet software.

The IRIDIUM9522B package includes all the hardware needed to get started. It consists of the Iridium 9522B modem (pn 30693) with mounting hardware, a COM9522B modem interface, the cabling needed for configuration and connection to a data logger, and an antenna with a mount. To connect the antenna to the 9522B modem, select a 18017-L coaxial antenna cable. An optional surge protection kit can be ordered with a Type N to TNC antenna cable.

Typically one Iridium 9522B is placed at the LoggerNet computer and at each of the remote data logging sites.

続きを読む

利点と特徴

  • Global coverage for data communication with any station that has a view of the sky
  • On demand, two-way communication with your station
  • No antenna pointing required—omnidirectional antenna
  • Supports dial-up, RUDICS, and SBD communications
  • COM9522B makes it easy to interface the Iridium transceiver to a data logger serial port and to control the transceiver’s power

イメージ

Complete IRIDIUM9522B satellite modem and interface kit
Complete IRIDIUM9522B satellite modem and interface kit
Complete IRIDIUM9522B satellite modem and interface kit
COM9522B interface and 30693 transceiver

詳細

The Iridium satellite network consists of 66 satellites sitting in six planes. The planes are evenly spaced flying in polar orbits at low altitudes. This configuration provides global data coverage that supports communication with a station located anywhere on earth, as long as it has a clear view of the sky. The Iridium satellite system is ideal for stations at very high-angle latitudes (greater than 70° North or South), high-altitude applications, and mobile applications, such as buoys or ships.

仕様

-NOTE- The IRIDIUM9522B is a kit containing several components that have their own specifications.

To review these specifications, refer to the appropriate products below:

Transmission Distance or Area Worldwide (including poles, oceans, and airways)
Service Requirements Needs a SIM card. Must select a service provider and pay a fee.
Weight 1.7 kg (3.75 lb)

System (30693 and COM 9522B)

Operating Voltage 4 to 32 Vdc
Current Drain at 12 Vdc
  • 20 µA (off state)
  • 500 mA (transmission)
  • 333 mA (operating)
  • 125 mA (standby)

互換性

注意: 以下は代表的な互換性情報を示しています。互換性のある製品や互換性のない製品をすべて網羅したリストではありません。

Data Loggers

製品 互換性 注意
21X (リタイア)
CR10 (リタイア)
CR1000 (リタイア)
CR1000X (リタイア)
CR10X (リタイア)
CR200X (リタイア)
CR206X (リタイア)
CR211X (リタイア)
CR216X (リタイア)
CR23X (リタイア)
CR295X (リタイア)
CR300 (リタイア) Use a 18663 null modem cable.
CR3000 (リタイア)
CR310 Use a 18663 null modem cable.
CR500 (リタイア)
CR5000 (リタイア)
CR510 (リタイア)
CR6
CR800 (リタイア)
CR850 (リタイア)
CR9000 (リタイア)
CR9000X (リタイア)

Mounting Equipment

製品 互換性 注意
ENC10/12
ENC10/12R
ENC12/14
ENC14/16
ENC16/18

互換性に関する追加情報

Model 9522B (pn 30693) used in the IRIDIUM9522B package is a satellite modem designed to operate with the Iridium network. The 9522B service support includes dial-up data, short-burst data (SBD), and RUDICS (router-based unrestricted digital internetworking connectivity solutions). LoggerNet software is used for dialing up the remote or connecting to a RUDICS server.

When attached to a device that will simply wait to be dialed up, the Iridium 9522B is compatible with any RS-232 serial device. When the remote Iridium 9522B is dialed up, generally by LoggerNet, the link is transparent and provides a high latency "serial cable replacement" type of solution. When attached to a device that will perform the dialing, such as a remote station calling back to LoggerNet, the Iridium 9522B needs to be controlled by a PC or data logger capable of sending the required AT commands through the RS-232 serial port.

When used for SBD, the Iridium 9522B must be connected to a device, such as a data logger, that is capable of sending the required AT commands through the RS-232 serial port.

Software

LoggerNet provides support for communicating with our data loggers over the the Iridium network using the Iridium 9522B. LoggerNet provides user control by allowing direct communications with the remote station using the Iridium Dial-up or RUDICS services. LoggerNet can run unattended, providing scheduled communications for data and image collection, as well as remote station administration.

Iridium Service Requirements

To use the Iridium satellite system, customers must select a service provider. When choosing a provider, evaluate their service while comparing costs. Most plans have a monthly base service fee for each Iridium subscriber unit (ISU), as well as charges for the amount of airtime or data used. Contact Campbell Scientific for more information about Iridium communications or assistance in locating a provider.

Enclosure Considerations

The COM9522B of the kit requires a desiccated, non-condensing environment; a Campbell Scientific enclosure is recommended. Grommets and screws are provided to attach the COM9522B to the backplate of our enclosures.


よくある質問

IRIDIUM9522Bに関するよくある質問の数: 1

  1. There are many Iridium service providers who can be contacted directly. Alternatively, contact Campbell Scientific for assistance in locating a provider, such as our integrators who resell Iridium services.


記事とプレスリリース

Privacy Policy Update

We've updated our privacy policy.  詳細はこちら

Cookie Consent

Update your cookie preferences.  クッキーの設定を更新する