The LI200X, manufactured by LI-COR, is a pyranometer that monitors sun plus sky radiation. It connects directly to our data loggers, and is used extensively in solar, agricultural, and meteorological applications.
続きを読むThe LI200X uses a silicon photovoltaic detector mounted in a cosine-corrected head to provide solar radiation measurements. Calibrated against an Eppley precision spectral pyranometer (PSP), the LI200X accurately measures sun plus sky radiation for the spectral range of 400 to 1100 nm. Sensors calibrated to this spectral range should not be used under vegetation or artificial lights.
The LI200X includes an epoxy-encased completion circuit in its cable. This completion circuit standardizes the sensor's sensor's calibration, allowing individual sensors to be interchanged without altering multiplier and offset values.
The standard output is 0.005 mV per W m-2, which provides a signal of 5 mV in full sunlight (1000 W m-2). All of our data loggers, except the CR200(X) series, can measure this output.
Light Spectrum Waveband | 400 to 1100 nm |
Accuracy | Absolute error in natural daylight is ±5% maximum (±3% typical) |
Sensitivity | 0.2 kW m-2 mV-1 |
Linearity | Maximum deviation of 1% up to 3000 W m-2 |
Shunt Resistor | Adjustable, 40.2 to 90.2 ohm (factory set to the above sensitivity) |
Stability | < ±2% change over a 1 year period |
Response Time | 10 μs |
Temperature Dependence | 0.15% per °C (maximum) |
Cosine Correction | Cosine corrected up to 80° angle of incidence |
Operating Temperature Range |
-40° to +65°C The overmolding that protects the completion circuit in the cable may crack if the temperature drops below -40°C. |
Relative Humidity Range | 0 to 100% |
Detector | High stability silicon photovoltaic detector (blue enhanced) |
Sensor Housing | Weatherproof anodized aluminum case with acrylic diffuser and stainless-steel hardware |
Diameter | 2.38 cm (0.94 in.) |
Height | 2.54 cm (1.00 in.) |
Weight | 28 g (1 oz) |
注意: 以下は代表的な互換性情報を示しています。互換性のある製品や互換性のない製品をすべて網羅したリストではありません。
製品 | 互換性 | 注意 |
---|---|---|
21X (リタイア) | ||
CR10 (リタイア) | ||
CR1000 (リタイア) | ||
CR10X (リタイア) | ||
CR200X (リタイア) | ||
CR206X (リタイア) | ||
CR211X (リタイア) | ||
CR216X (リタイア) | ||
CR23X (リタイア) | ||
CR295X (リタイア) | ||
CR3000 (リタイア) | ||
CR500 (リタイア) | ||
CR5000 (リタイア) | ||
CR510 (リタイア) | ||
CR6 | ||
CR800 (リタイア) | ||
CR850 (リタイア) | ||
CR9000 (リタイア) | ||
CR9000X (リタイア) |
To ensure accurate measurements, the sensor should be leveled using a LI2003S leveling fixture, which incorporates a bubble level and three adjusting screws. The LI2003S leveling fixture mounts to a tripod or tower using the CM225 mount. For most applications, Campbell Scientific recommends attaching the CM225 to a CM202, CM204, or CM206 crossarm. The CM225 can also be attached to a tripod or tower mast.
One differential analog input channel per probe is required.
LI200X-Lに関するよくある質問の数: 6
すべて展開すべて折りたたむ
The LI190SB-L measures photosynthetically active radiation (PAR), a spectral range of solar radiation from 400 to 700 nm. This is the energy that plants use during photosynthesis. Measurements with the LI190SB-L are reported as photosynthetic photon flux density (PPFD).
The LI200X-L measures total solar radiation from 400 to 1100 nm. Measurements are usually reported in units of W/m2.
キャリブレーション シートに含まれる情報は、センサごとに異なります。一部のセンサでは、シートにデータロガーをプログラムするために必要な係数が含まれています。その他のセンサでは、キャリブレーション シートは合格/不合格レポートです。
すべてのセンサに異なるケーブル終端オプションがあるわけではありません。特定のセンサで利用可能なオプションは、センサ製品ページの注文情報エリアの 2 つの場所で確認できます。
モデル番号
ケーブル終端オプション リスト
センサが –ET、–ETM、–LC、–LQ、または –QD バージョンで提供されている場合、そのオプションが利用可能かどうかはセンサモデル番号に反映されます。たとえば、034B は 034B-ET、034B-ETM、034B-LC、034B-LQ、および 034B-QD として提供されています。
その他のすべてのケーブル終端オプション (利用可能な場合) は、センサ製品ページの注文情報エリアの「ケーブル終端オプション」の下にリストされています。たとえば、034B-L 風力発電セットは、034B-L 製品ページの注文情報エリアに示されているように、–CWS、–PT、および –PW オプションで提供されています。
注意: 新しい製品が在庫に追加されると、通常は複数のモデル番号を作成するのではなく、1 つのセンサモデルの下に複数のケーブル終端オプションをリストします。たとえば、HC2S3-L には、HC2S3-LC モデルではなく、CS110 に接続するための –C ケーブル終端オプションがあります。
Campbell Scientific のセンサのほとんどは、ユーザー指定のケーブル長を示す –L として提供されています。センサが –LX モデル (「X」は他の文字) としてリストされている場合、そのセンサのケーブルの長さはユーザー指定ですが、固有のシステム用の特定のコネクタで終端されます。
センサのメイン モデル番号の後に –L または –LX の指定がない場合、センサのケーブル長は設定されています。ケーブル長は、製品の注文情報の説明フィールドの末尾に記載されています。たとえば、034B-ET モデルの説明は、「ET ステーション用 Met One Wind セット、67 インチ ケーブル」です。ケーブル長が設定されている製品は、デフォルトでバラ線で終端されます。
ケーブルが特定のシステム用の特別なコネクタで終端されている場合、モデル番号の末尾でそのシステムを指定します。たとえば、034B-ET モデルは、ET107 システムのセンサを 034B として指定します。
これは、キャリブレーション シートに含まれる情報によって異なります。
多くの Campbell Scientific センサは、さまざまなケーブル終端オプションで利用できます。これらのオプションには次のものがあります。
注意: ケーブル終端オプションの選択肢はセンサによって異なります。たとえば、センサには選択可能なオプションがまったくないか、複数ある場合があります。特定のセンサに必要なオプションがリストされていない場合は、Campbell Scientific に問い合わせてサポートを受けてください。
We've updated our privacy policy. 詳細はこちら
Update your cookie preferences. クッキーの設定を更新する