RETIRED ›
This product is no longer available and has been replaced by: MD485.
MD9 Multidrop Interface
利用できるサービス
修理 非対応
キャリブレーション 非対応
フリーサポート 非対応

概要

Effective 1 January 2004, the MD9 Multidrop Interface was generally replaced for new multidrop applications by the MD485 Multidrop Interface. However, the MD9 remains available for customers with existing MD9 networks.

The MD9 Multidrop Interface links a computer to as many as 200 data loggers over a single coaxial cable. Each data logger in the network is connected to an MD9 that has a unique, user-assigned address. Communication between the computer and a specific data logger is routed through the MD9’s address allowing the rest of the network to remain in quiescent mode. Total coaxial cable length can be up to three miles; each MD9 in the network slightly reduces the maximum transmission distance.

続きを読む

イメージ

詳細

Effective 1 January 2004, the MD9 Multidrop Interface was generally replaced for new multidrop applications by the MD485 Multidrop Interface. The MD9 remains available for customers who have MD9 networks currently deployed in the field. MD9s and MD485s can NOT be used in the same network.

The MD9 Multidrop Interface links a central computer to up to 200 data loggers on a single coaxial cable. Total cable length can be up to 3 miles. At least two MD9s are required within a network.

仕様

Baud Rates 9600, 1200, 300 (hardware-selectable)
Current Drain
  • 1.2 mA (quiescent)
  • 80.0 mA (active)
Operating Voltage 5 Vdc (from the PS150 or SC532(A) interface)
Carrier Frequency 1.2 MHz
Operating Temperature Range
  • -25° to +50°C (standard)
  • -55° to +85°C (extended)
Dimensions 16.2 x 8.8 x 3.0 cm (6.4 x 3.5 x 1.2 in.) including connectors
Weight 227 g (8 oz)

互換性

注意: 以下は代表的な互換性情報を示しています。互換性のある製品や互換性のない製品をすべて網羅したリストではありません。

Data Loggers

製品 互換性 注意
21X (リタイア) The 21X should have a serial number of 6195 or higher (others require factory modification and an RMA).
CR10 (リタイア)
CR1000 (リタイア) Requires LoggerNet 4.2 or higher.
CR10X (リタイア) The -PB versions of the CR10X requires LoggerNet 4.2 or higher.
CR200X (リタイア)
CR206X (リタイア)
CR211X (リタイア)
CR216X (リタイア)
CR23X (リタイア) The -PB versions of the CR23X requires LoggerNet 4.2 or higher.
CR295X (リタイア)
CR3000 (リタイア) Requires LoggerNet 4.2 or higher.
CR500 (リタイア)
CR5000 (リタイア)
CR510 (リタイア) The -PB versions of the CR510 requires LoggerNet 4.2 or higher.
CR800 (リタイア) Requires LoggerNet 4.2 or higher.
CR850 (リタイア) Requires LoggerNet 4.2 or higher.
CR9000 (リタイア)
CR9000X (リタイア)

ドキュメント


よくある質問

MD9に関するよくある質問の数: 1

  1. Yes, but only if all the other data loggers are PakBus devices, such as the CR800, CR850, and CR1000.

ケーススタディ

カリフォルニア: 海岸斜面の監視
カリフォルニア州サンディエゴ郡のノース カウンティ トランジット ディストリクト (NCTD) は、デル マーの海岸沿いの崖の上にある 3 区間の線路で、危険な斜面の変動を監視する必要があると判断しました。これにより、3,300 フィート (1,000 メートル) の線路に沿った継続的な監視システムが開発されました。監視対象の長さのため、複数の傾斜計や設置型傾斜計 (IPI) などの従来の単一ポイント監視システムの使用は実用的ではありませんでした。崖の崩壊は線路のどこででも発生する可能性があるため、単一ポイントの計器を使用するには、多数のセンサーとモニターが必要になります。代わりに、線路の危険度の高い区間に沿って、水平時間領域反射率測定......続きを読む
オーストラリア: 二酸化炭素と気候変動の影響の調査
オーストラリアのタウンズビルに、二酸化炭素濃度の上昇と気候変動が熱帯サバンナに影響を与えるための実験施設 (OzFace) が設置されました。世界中には他にも自由大気二酸化炭素濃縮 (FACE) システムがいくつかありますが、OzFace システムはオーストラリア初であり、熱帯サバンナで実施される世界初のシステムです。Campbell Scientific Australia が設計および構築した OzFace システムは、Queensland Nickel Pty主な目的は、自然条件下で、制御された高レベルの CO2 が生態系に与える影響を調査することです。これは単純に聞こえますが、風速と風向が変化する状況で......続きを読む

以下に記載

下記製品のその他アクセサリです:

Privacy Policy Update

We've updated our privacy policy.  詳細はこちら

Cookie Consent

Update your cookie preferences.  クッキーの設定を更新する