風向風速計 / 05103-45-L
RETIRED ›
This product is no longer available and has been replaced by: 05108-45-L.
05103-45-L Wind Monitor, Alpine Version
利用できるサービス
修理 対応
キャリブレーション 非対応
フリーサポート 対応

概要

The 05103-45 Wind Monitor is a lightweight instrument that measures wind speed and wind direction. It is designed to prevent ice buildup, allowing the sensor to provide accurate measurements in harsh alpine conditions. Manufactured by R. M. Young, this wind monitor is cabled for use with Campbell Scientific data loggers.

続きを読む

利点と特徴

  • Smaller propeller diameter minimizes vibration at high wind speeds
  • Discourages ice-buildup with a black sensor housing that is covered with an ice-resistant coating
  • Compatible with most Campbell Scientific data loggers
  • Uses stainless-steel, precision-grade ball bearings for the propeller shaft and vertical shaft bearings
  • Rugged enough for harsh environments
  • Compatible with the LLAC4 4-channel Low-Level AC-Conversion Module, which increases the number of anemometers one data logger can measure
  • Compatible with the CWS900-series interfaces, allowing it to be used in a wireless sensor network

イメージ

詳細

The 05103-45 is constructed from rigid UV-stabilized thermoplastic, and has stainless steel and anodized aluminum fittings. The thermoplastic material resists corrosion from sea air environments and atmospheric pollutants. It uses stainless-steel precision-grade ball bearings for the propeller shaft and vertical shaft bearings.

Designed for harsh alpine conditions, the 05103-45 has a smaller propeller diameter than the other wind monitor models, which minimizes vibration at high wind speeds. To discourage ice buildup, the sensor's housing is black and covered with an ice-resistant coating.

The 05103-45 measures wind speed with a helicoid-shaped, four-blade propeller. Rotation of the propeller produces an ac sine wave that has a frequency directly proportional to wind speed. The ac signal is induced in a transducer coil by a six-pole magnet mounted on the propeller shaft. The coil resides on the non-rotating central portion of the main mounting assembly, eliminating the need for slip rings and brushes.

Wind direction is sensed by the orientation of the fuselage-shaped sensor body, which is connected to an internal potentiometer. The data logger applies a known precision excitation voltage to the potentiometer element. The output is an analog voltage signal directly proportional to the azimuth angle.

仕様

Operating Temperature Range -50° to +50°C (assuming non-riming conditions)
Mounting Pipe Description
  • 34 mm (1.34 in.) OD
  • Standard 1.0-in. IPS schedule 40
Propeller Diameter 14 cm (5.5 in.)
Overall Height 37 cm (14.6 in.)
Main Housing Diameter 5 cm (2.0 in.)
Overall Length 55 cm (21.7 in.)
Weight 1 kg (2.2 lb)

Wind Speed

Range 0 to 100 m/s (0 to 224 mph)
Accuracy ±0.3 m/s (0.6 mph) or 1% of reading
Starting Threshold 1.0 m/s (2.2 mph)
Distance Constant 2.7 m (8.9 ft) 63% recovery
Output ac voltage (three pulses per revolution)

90 Hz (1800 rpm) = 8.8 m/s (19.7 mph)
Resolution (0.0980 m s-1)/(scan rate in seconds) or (0.2192 mph)/(scan rate seconds)

Wind Direction

Mechanical Range 0 to 360°
Electrical Range 355° (5° open)
Accuracy ±3°
Starting Threshold 1.1 m/s (2.4 mph) at 10° displacement
Distance Constant 1.3 m (4.3 ft) 50% recovery
Damping Ratio 0.3
Damped Natural Wavelength 7.4 m (24.3 ft)
Undamped Natural Wavelength 7.2 m (23.6 ft)
Output
  • Analog dc voltage from potentiometer (resistance 10 kohm)
  • Linearity is 0.25%.
  • Life expectancy is 50 million revolutions.
Voltage Power switched excitation voltage supplied by data logger

互換性

注意: 以下は代表的な互換性情報を示しています。互換性のある製品や互換性のない製品をすべて網羅したリストではありません。

Data Loggers

製品 互換性 注意
21X (リタイア)
CR10 (リタイア)
CR1000 (リタイア)
CR1000X (リタイア)
CR10X (リタイア)
CR200X (リタイア)
CR206X (リタイア)
CR211X (リタイア)
CR216X (リタイア)
CR23X (リタイア)
CR295X (リタイア)
CR300 (リタイア)
CR3000 (リタイア)
CR310
CR500 (リタイア) Measurements are typically processed for output with the Wind Vector instruction, which is not present in the CR500.
CR5000 (リタイア)
CR510 (リタイア)
CR800 (リタイア)
CR850 (リタイア)
CR9000 (リタイア) Measurements are typically processed for output with the Wind Vector instruction, which is not present in the CR9000.
CR9000X (リタイア)

互換性に関する追加情報

Mounting

The 05103-45 can be attached to a crossarm via a 17953 NU-RAIL fitting or CM220 Right Angle Mounting Bracket. Alternatively, it can be attached to the top of a CM106B or stainless-steel tripod via the CM216 Sensor Mounting Kit.

Wind Profile Studies

Wind profile studies measure many wind sensors. For these applications, the LLAC4 4-Channel Low Level AC Conversion Module can be used to increase the number of Wind Monitors measured by one data logger. The LLAC4 allows data logger control ports to read the wind speed sensor’s ac signals instead of using pulse channels. Data loggers compatible with the LLAC4 are the CR200(X) series (ac signal ≤1 kHz only), CR800, CR850, CR1000, CR3000, and CR5000.

Data Logger Considerations

The 05103-45's propeller uses one pulse count channel on the data logger. Its wind vane requires one single-ended channel and access to an excitation channel (the excitation channel can be shared with other high impedance sensors).

Programming

The 05103-45's propeller is measured by the PulseCount Instruction in CRBasic and by Instruction 3 (Pulse Count) in Edlog. The wind vane is measured by the BrHalf Instruction in CRBasic and by Instruction 4 (Excite-Delay-SE) in Edlog. The measurements are typically processed for output with the Wind Vector instruction (not present in the CR500 or CR9000 but is present in the CR9000X).

動画とチュートリアル

よくある質問

05103-45-Lに関するよくある質問の数: 11

すべて展開すべて折りたたむ

  1. This depends on what is broken. Typically, Campbell Scientific can repair the unit, and the user does not have to purchase a new one.

  2. The measurement instructions will likely remain the same. However, in addition to the multiplier and offset, the type of pulse may change for the wind speed, and the excitation voltage may change for the wind direction. For an explanation of how the data logger needs to be programmed, see the instruction manual.

  3. The short answer is less than 0.01 mA. The wind speed signal requires no power. The wind direction portion of the sensor only uses a maximum of 0.5 mA when excited with 5 Vdc, and then it is only on for 0.016 s for every measurement. When the wind direction is measured every second (typical), the average current drain is less than 0.01 mA.

  4. Orientation of the wind monitor is done after the data logger has been programmed, and the location of True North has been determined. True North is usually found by reading a magnetic compass and applying the correction for magnetic declination, where magnetic declination is the number of degrees between True North and Magnetic North. Magnetic declination for a specific site can be obtained from a USFA map, local airport, or through a computer service.

  5. すべてのセンサに異なるケーブル終端オプションがあるわけではありません。特定のセンサで利用可能なオプションは、センサ製品ページの注文情報エリアの 2 つの場所で確認できます。

    モデル番号
    ケーブル終端オプション リスト
    センサが –ET、–ETM、–LC、–LQ、または –QD バージョンで提供されている場合、そのオプションが利用可能かどうかはセンサモデル番号に反映されます。たとえば、034B は 034B-ET、034B-ETM、034B-LC、034B-LQ、および 034B-QD として提供されています。

    その他のすべてのケーブル終端オプション (利用可能な場合) は、センサ製品ページの注文情報エリアの「ケーブル終端オプション」の下にリストされています。たとえば、034B-L 風力発電セットは、034B-L 製品ページの注文情報エリアに示されているように、–CWS、–PT、および –PW オプションで提供されています。

    注意: 新しい製品が在庫に追加されると、通常は複数のモデル番号を作成するのではなく、1 つのセンサモデルの下に複数のケーブル終端オプションをリストします。たとえば、HC2S3-L には、HC2S3-LC モデルではなく、CS110 に接続するための –C ケーブル終端オプションがあります。

  6. Most Campbell Scientific sensors are available as an –L, which indicates a user-specified cable length. If a sensor is listed as an –LX model (where “X” is some other character), that sensor’s cable has a user-specified length, but it terminates with a specific connector for a unique system:

    • An –LC model has a user-specified cable length for connection to an ET107, CS110, or retired Metdata1.
    • An –LQ model has a user-specified cable length for connection to a RAWS-P weather station.

    If a sensor does not have an –L or other –LX designation after the main model number, the sensor has a set cable length. The cable length is listed at the end of the Description field in the product’s Ordering information. For example, the 034B-ET model has a description of “Met One Wind Set for ET Station, 67 inch Cable.” Products with a set cable length terminate, as a default, with pigtails.

    If a cable terminates with a special connector for a unique system, the end of the model number designates which system. For example, the 034B-ET model designates the sensor as a 034B for an ET107 system.

    • –ET models terminate with the connector for an ET107 weather station.
    • –ETM models terminate with the connector for an ET107 weather station, but they also include a special system mounting, which is often convenient when purchasing a replacement part.
    • –QD models terminate with the connector for a RAWS-F Quick Deployment Station.
    • –PW models terminate with the connector for a PWENC or pre-wired system.
    1. Using Short Cut, click the applicable wind direction sensor in the Selected Sensors list of the Outputs screen.
    2. The two output options enabled are Sample and WindVector. Select WindVector.
    3. The WindVector instruction has output options. Select an option with mean wind direction in it.
  7. Many Campbell Scientific sensors are available with different cable termination options. These options include the following:

    • The –PT (–PT w/Tinned Wires) option is the default option and does not display on the product line as the other options do. The cable terminates in pigtails that connect directly to a data logger.
    • In the –C (–C w/ET/CS110 Connector) option, the cable terminates in a connector that attaches to a CS110 Electric Field Meter or an ET-series weather station.
    • In the –CWS (–CWS w/CWS900 Connector) option, the cable terminates in a connector that attaches to a CWS900-series interface. Connection to a CWS900-series interface allows the sensor to be used in a wireless sensor network.
    • In the –PW (–PW w/Pre-Wire Connector) option, the cable terminates in a connector that attaches to a prewired enclosure.
    • In the –RQ (–RQ w/RAWS Connector) option, the cable terminates in a connector that attaches to a RAWS-P Permanent Remote Automated Weather Station.

    Note: The availability of cable termination options varies by sensor. For example, sensors may have none, two, or several options to choose from. If a desired option is not listed for a specific sensor, contact Campbell Scientific for assistance.

Privacy Policy Update

We've updated our privacy policy.  詳細はこちら

Cookie Consent

Update your cookie preferences.  クッキーの設定を更新する