The SR50A-316SS is a stainless-steel version of Campbell Scientific's acoustic sensor for measuring the distance from the sensor to a target. The stainless-steel chassis allows for operation in environments where corrosion is a concern (such as marine environments). It is typically used to measure snow or water depth, but it is well-suited for other uses.
This measurement can be used to determine snow or water depth. An air temperature measurement is required to correct for variations of the speed of sound in air. This sensor is compatible with most Campbell Scientific data loggers.
続きを読むThe SR50A-316SS was designed to meet the stringent requirements of measuring depths and uses a multiple echo processing algorithm to help ensure measurement reliability.
SDI-12, RS-232, and RS-485 output options are available for measuring the SR50A-316SS. Campbell Scientific’s MD485 interface can be used to connect one or more SR50A-316SS sensors in RS-485 mode to an RS-232 device. This can be useful for sensors that require lead lengths that exceed the limits of either RS-232 or SDI-12 communications. The SR50AH-L is available with a heater option for locations where rime ice is a problem.
The SR50A replaced the SR50 in March 2007. The newer SR50A is smaller and has different output options than its predecessor.
Measurement Time | < 1.0 s |
Output Options | SDI-12 version 1.3, RS-232, RS-485 (output options selected by configuring internal jumpers) |
Baud Rates | 1200 to 38400 bps (RS-232, RS-485 modes) |
Power Requirements | 9 to 18 Vdc (typically powered by data logger’s 12 Vdc power supply) |
Measurement Range | 0.5 to 10 m (1.6 to 32.8 ft) |
Beam Acceptance | ~30° |
Resolution | 0.25 mm (0.01 in.) |
Accuracy | ±1 cm (0.4 in.) or 0.4% of distance to target (whichever is greatest). Requires external temperature compensation. |
Operating Temperature Range | -45° to +50°C |
Compliance | CE compliant |
Length | 10.1 cm (4.0 in.) |
Diameter | 7.5 cm (3 in.) |
Weight | 795 g (28 oz) without cable |
Cable Weight | 250 g (8.2 oz) for a 4.57-m (15-ft) cable |
Maximum Cable Length |
|
-NOTE- | Cable lengths greater than 60 m require a heavier gage wire if the power supply drops below 11 Vdc. |
SDI-12 | 60 m (200 ft) |
RS-232 | 60 m (200 ft) Baud rates ≤ 9600 bps |
RS-485 | 300 m (984 ft) |
Power Consumption |
|
Active | 250 mA (typical) |
Quiescent SDI-12 Mode | < 1.0 mA |
Quiescent RS-232/RS-485 Modes |
|
注意: 以下は代表的な互換性情報を示しています。互換性のある製品や互換性のない製品をすべて網羅したリストではありません。
製品 | 互換性 | 注意 |
---|---|---|
21X (リタイア) | SDI-12 | |
CR10 (リタイア) | SDI-12 | |
CR1000 (リタイア) | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR1000X (リタイア) | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR10X (リタイア) | SDI-12 | |
CR200X (リタイア) | SDI-12 | |
CR206X (リタイア) | SDI-12 | |
CR211X (リタイア) | SDI-12 | |
CR216X (リタイア) | SDI-12 | |
CR23X (リタイア) | SDI-12 | |
CR295X (リタイア) | SDI-12 | |
CR300 (リタイア) | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR3000 (リタイア) | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR310 | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR500 (リタイア) | SDI-12 | |
CR5000 (リタイア) | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR510 (リタイア) | SDI-12 | |
CR6 | SDI-12, RS-232, and RS-485 | |
CR800 (リタイア) | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR850 (リタイア) | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR9000 (リタイア) | ||
CR9000X (リタイア) | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. |
製品 | 互換性 | 注意 |
---|---|---|
Granite 6 | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. |
One single-ended channel per probe is required; an excitation channel can be shared by several probes.