OBS501 Smart Turbidity Meter with Antifouling Features
利用できるサービス
修理 非対応
キャリブレーション 非対応
フリーサポート 対応

概要

The OBS501 is a submersible turbidity probe with active antifouling capabilities for better measurements in biologically active water with both high and low turbidity. It outputs an SDI-12, digitally processed signal that many of our data loggers can measure. The OBS501 is similar to the OBS500, but the OBS501 has better mechanical performance in heavy sediment/sand conditions.

続きを読む

利点と特徴

  • Dual backscatter and sidescatter sensors used to measure turbidity
  • ClearSensor antifouling method for better measurements in biologically active water
  • Shutter/wiper mechanism keeps lenses clean
  • Refillable biocide chamber prevents fouling
  • Disposable plastic sleeve facilitates cleanup
  • Optional copper sleeve for additional protection (especially for sea water) or disposable plastic sleeve facilitates easy cleanup

イメージ

OBS501 in closed shutter position
OBS501 in closed shutter position
OBS501 in closed shutter position
OBS501 in open and closed shutter positions
OBS501 in open shutter position
OBS501 in closed shutter position with cable
Two sleeve options are offered. The three photographs show the plastic sleeve being removed.
Biological fouling on a closed sensor (far left) and an opened sensor after 86 days of deployment in the Atlantic Ocean.

詳細

Design features of the OBS501 include the combination of a backscatter sensor (better at measuring higher turbidity) with a second sidescatter sensor (better at measuring lower turbidity). It has a shutter that is opened only during measurements, which reduces the time that algae or other organisms can cling to its optics.

The OBS501 is constructed to prevent sand grains or packed sediment from getting wedged between the shutter and sensor body, which inhibits the shutter’s movement. To do this, the OBS501's shutter and body were designed to eliminate parallel surfaces between moving parts wherever possible. The probe also uses a flushing action that moves the sediment down and out of the cavity behind the shutter.

To prevent biofouling and ensure better measurements, the OBS501 incorporates the ClearSensor Method  (U.S. Patent No. 8,429,952. This method uses a shutter/wiper mechanism to protect and clean the optics. With the ClearSensor method, a chamber is also filled with a biocide that continuously leaches out over the optics while the probe shutter is in the closed position. ClearSensor® and OBS® are registered trademarks of Campbell Scientific.

The OBS501 can sense if the shutter’s motor is working harder than normal. If it is, the shutter moves slightly back and forth to dislodge sand grains before fully opening or closing.

Campbell Scientific offers a disposable, plastic sleeve that can make cleanup a snap, as well as a copper sleeve that can provide additional protection, especially in sea water.

仕様

Dual Probe 90° sidescatter and backscatter
Measurement Range 0 to 4000 NTU
Active and Passive Antifouling Shutter, wiper, biocide, copper, optional removable sleeve
Accuracy ±2% of reading or 0.5 NTU (whichever is greater)
Operating Temperature Range 0° to 40°C
Storage Temperature Range 0° to 40°C
Temperature Accuracy ±0.3°C
Emitter Wavelength 850 nm
Power Requirements 9.6 to 18 Vdc
Measurement Time < 10 s
Maximum Submersion Depth 100 m (330 ft)
Diameter 4.8 cm (1.88 in.)
Maximum Cable Length
  • 116 m (380 ft) for 1 channel SDI-12 or analog
  • 15 m (50 ft) for RS-232
Length 27 cm (10.63 in.)
Weight 0.59 kg (1.30 lb)

Power Consumption

Quiescent < 200 µA
Measurement < 40 mA
Communication < 40 mA
Active Shutter Motor < 380 mA

Outputs

SDI-12 Version 1.3, 1200 bps
RS-232 9600 bps, 8 data bits, 1 stop bit, no parity, no flow control
Analog 0 to 5 Vdc

互換性

注意: 以下は代表的な互換性情報を示しています。互換性のある製品や互換性のない製品をすべて網羅したリストではありません。

Data Loggers

製品 互換性 注意
21X (リタイア)
CR10 (リタイア)
CR1000 (リタイア)
CR1000X (リタイア)
CR10X (リタイア)
CR200X (リタイア)
CR206X (リタイア)
CR211X (リタイア)
CR216X (リタイア)
CR23X (リタイア)
CR295X (リタイア)
CR300 (リタイア)
CR3000 (リタイア)
CR310
CR500 (リタイア)
CR5000 (リタイア)
CR510 (リタイア)
CR6
CR800 (リタイア)
CR850 (リタイア)
CR9000 (リタイア)
CR9000X (リタイア)

よくある質問

OBS501に関するよくある質問の数: 1

  1. It used to be that NTUs were the unit for all turbidity sensors. In 2007, an ASTM committee formed and established different units for each category of turbidity sensor technology, and there are many. Backscatter sensors such as the OBS-3+ and the OBS501 have units of FBU (Formazin Backscatter Units), whereas ISO 7027 side-scatter sensors have units of FNU (Formazin Nephelometric Units). The side-scatter OBS501 and the ClariVue™ sensors are part of this category. While sensors of different technical designs can be calibrated and measure Formazin the same, they will not make the same measurement in natural waters where size, shape, color, reflectivity, etc., of the particles vary. The ClariVue™ sensor measurements will not match the OBS-3+ measurements in natural waters.

ケーススタディ

Panama: Turbidity in Mine Runoff
Water and Earth Technologies (WET), a Campbell Scientific integrator, is a water resources and environmental engineering firm.......続きを読む
Costa Rica: Buoy System
Overview The existing port of Limon was constructed over 30 years ago. With the increase of......続きを読む

下記の製品は置き換えられました

Privacy Policy Update

We've updated our privacy policy.  詳細はこちら

Cookie Consent

Update your cookie preferences.  クッキーの設定を更新する