RETIRED ›
This product is no longer available.
SDM-CVO4 4-Channel Current and Voltage Output Module
利用できるサービス
修理 対応
キャリブレーション 対応
フリーサポート 対応

概要

The SDM-CVO4 is attached to a data logger and outputs variable voltage or current signals under data logger program control. Typical applications include driving remote current-loop display units, retransmitting measured values to industrial control systems, sending control signals to valve controllers, and providing excitation voltages or currents to external sensors.

続きを読む

利点と特徴

  • Expands data logger current/voltage output capability
  • Provides four independent current or voltage outputs
  • Drives remote current-loop display units
  • Retransmits measured values to industrial control systems that have current or high voltage inputs
  • Sends control signals to valve controllers
  • Provides excitation voltages or currents to external sensors

イメージ

Close-up of labels

詳細

The SDM-CVO4 includes four output channels for connecting the external devices. It outputs variable voltage or current signals under data logger program control. The outputs are isolated both from the data logger and the other channels on the SDM-CVO4, thereby avoiding ground loop problems. Each output can be set to 0 to 10 Vdc or 0 to 20 mA by the data logger program. (Current outputs can also be scaled and limited to 4 to 20 mA.)

In the current mode, the output either acts as a two-wire current controller, where the loop is powered from a remote voltage source, or generates a 0 to 20 mA current source using a voltage output derived from its own power supply.

Isolation

The SDM-CVO4 includes an internal isolation barrier and components rated to provide signal isolation for transients up to 1500 Vac (rms), 2500 Vdc nominal. The isolation is between any output and the SDM-CVO4 ground connection and between individual output channels.

Protection components are built-in, which will break down in a controlled fashion at voltages close to this limit. (See the Instruction Manual, Section 4.5 Safety Considerations, for details).

仕様

Function Expands data logger current/voltage output capability.
Number of Channels 4
Operating Temperature -25 to +50°C
Operating Voltage 12 Vdc nominal (8 to 16 V)
Minimum Voltage Drop 2.5 V (@ 20 mA current flow) across the internal current regulating circuit
Maximum Input Voltage 20 Vdc (relative to channel ground)
EMC Status Complies with EN55022-1:1998 and EN50082-1:1998.
Dimensions
  • 17.8 x 10.2 x 2.3 cm (7.0 x 4.0 x 0.9 in.) without mounts
  • 23.4 x 11.2 x 2.3 cm (9.2 x 4.4. x 0.9 in.) with mounts
Weight 363 g (13 oz)

Isolation

Tested Isolation Each channel of each unit is tested for isolation resistance at 500 Vdc.

Pass level > 10 MΩ
Maximum Recommended Continuous Operating Voltage 240 Vac rms differential between an output and data logger ground, providing all issues relating to local regulations for safe installation and operation are followed (Refer to Section 4.5 Safety Considerations in the Instruction Manual.)

Current Mode

Range 0 to 20,000 µA
Resolution 5 µA
Minimum Output Current (leakage) 5 µA (at +50°C)
Accuracy at +23°C ±0.02% of set current + (±5 µA)
Typical Accuracy at -25° to +50°C ±0.1% of set current + (±5 µA)
Worst Case Accuracy at -25° to +50°C ±0.15% of full scale range + (±5 µA)

Voltage Mode

Range 0 to 10,000 mV
Resolution 2.5 mV
Maximum Output Current 30 mA per channel
Minimum Load Current 5 µA if output < 200 mV
Accuracy at +23°C ±0.02% of set voltage + (±2.5 mV)
Accuracy at -25° to +50°C ±0.13% of set voltage + (±2.5 mV)

Current Drain @ 12 Vdc

Typical Active Current 27 or 54 mA, depending on operating mode (no load on output ports)

To estimate the total current, add the active current to the sum of all output currents multiplied by 1.5. For example, if each port is at 10 mA output, the total = 54 + (1.5•4•10) = 114 mA.
With All Outputs Off < 0.5 mA

互換性

注意: 以下は代表的な互換性情報を示しています。互換性のある製品や互換性のない製品をすべて網羅したリストではありません。

Data Loggers

製品 互換性 注意
21X (リタイア)
CR10 (リタイア)
CR1000 (リタイア)
CR1000X (リタイア)
CR10X (リタイア)
CR200X (リタイア)
CR206X (リタイア)
CR211X (リタイア)
CR216X (リタイア)
CR23X (リタイア)
CR295X (リタイア)
CR300 (リタイア)
CR3000 (リタイア) For the CR3000, SDMs are connected to the ports labeled SDM-C1, SDM-C2, and SDM-C3.
CR310
CR500 (リタイア)
CR5000 (リタイア) For the CR5000, SDMs are connected to the ports labeled SDM-C1, SDM-C2, and SDM-C3.
CR510 (リタイア)
CR6
CR800 (リタイア)
CR850 (リタイア)
CR9000 (リタイア) Although the CR9000 is compatible, the SDM-CVO4 does not support its fastest communication rates and therefore may not be practical for CR9000 applications.
CR9000X (リタイア) Although the CR9000X is compatible, the SDM-CVO4 does not support its fastest communication rates and therefore may not be practical for CR9000X applications.

Mounting Equipment

製品 互換性 注意
ENC10/12
ENC10/12R
ENC12/14
ENC14/16
ENC16/18
ENC24/30
ENC24/30S

Distributed Data Acquisition

製品 互換性 注意
Granite 10
Granite 6
Granite 9

互換性に関する追加情報

Programming/Software

The SDMCVO4 instruction controls the SDM-CVO4 operation in CRBasic; Instruction 103 controls the SDM-CVO4 operation in Edlog.

Power Considerations

The SDM-CVO4 power requirements are large compared to most Campbell Scientific products—especially when driving significant loads. Care must be taken to ensure the power supply can deliver this higher demand. Alkaline batteries are not recommended for long-term applications.

The SDM-CVO4 has two internal power supplies—one for channels 1 and 2, and one for channels 3 and 4. The power supply for channels 3 and 4 is only turned on if the data logger sends an instruction that sets the output of those channels. If channels 3 and 4 are not used, the power consumption is approximately 20 mA lower than when all outputs are used.

Where supported by the data logger, and when the application allows it, the SDM-CVO4 can be shut down to reduce its power consumption to less than 0.5 mA. In this state, all outputs are switched off.

Enclosure Considerations

The SDM-CVO4 requires a desiccated, non-condensing environment; a Campbell Scientific enclosure is recommended. A mounting bracket, grommets, and screws attach the SDM-CVO4 to the backplates of a Campbell Scientific enclosure.


よくある質問

SDM-CVO4に関するよくある質問の数: 5

すべて展開すべて折りたたむ

  1. The SDM-CVO4 allows most Campbell Scientific data loggers to produce a value by whatever means measured or derived as a scaled 0 to 20 or 4 to 20 mA signal (four terminals).

    The data logger sends an instruction to the SDM-CVO4 with the voltage or current to be transmitted to the other device. The SDM-CVO4 does not itself convert a voltage to a current. A data logger is needed to make a measurement and instruct the SDM-CVO4 as to what the output should be. 

  2. はい。SDM デバイスは 0 から F までの 16 進数でアドレス指定できるため、データロガーには最大 15 個の SDM デバイスを接続できます。これらのデバイスの中には、より多くの電力を必要とするものもあるため、デバイスを追加する際にはこれを考慮する必要があります。

  3. はい。CR3000 と CR5000 には、ネイティブの連続アナログ出力チャネルが 2 つあります。SDM-AO4A (電圧) または SDM-CVO4 (電圧または電流) も使用できます。

  4. CR1000 の場合、連続アナログ出力を得るには、SDM-AO4A (4 チャネル、非絶縁、電圧のみ) または SDM-CVO4 (4 チャネル、絶縁、電圧または電流) が必要です。これらのデバイスを複数使用して、より多くの出力を得ることができます。単一チャンネルの出力の場合は、サードパーティ製のデバイスを使用できます。

  5. 連続アナログ出力を得るには、SDM-AO4A (4 チャンネル、非絶縁、電圧のみ) または SDM-CVO4 (4 チャンネル、絶縁、電圧または電流) のいずれかが必要です。これらのデバイスを複数使用して、より多くの出力を取得できます。

ケーススタディ

ルイジアナ州: 陥没穴監視
2012 年 8 月、RESPEC は、ルイジアナ州ナポレオンビル岩塩ドームの西側斜面で発生しつつある陥没穴に現場計測機器と早期警報監視サービスを提供する契約を締結しました。地下深くの塩水洞窟で構造的な亀裂が発生し、周囲の堆積物が洞窟に流れ込み、地表に陥没穴ができ、かき乱された堆積物からガスが放出されました。時間が経つにつれて、陥没穴は 40 エーカー以上に拡大し、最大深度では 400 フィートを超えました。 RESPEC のエンジニアは、発生しつつある陥没穴の周囲の傾斜と水位を継続的に監視するために、リアルタイムの早期警告システムを導入しました。陥没穴は沿岸のヒノキ沼地にあるため、監視システムは過酷な条件 (例: 猛暑、極度の湿度、ハリケーン、大雨、昆虫) で最小限のメンテナンスで稼働する必要がありました。このシステムは、Campbell Scientific のデータ......続きを読む
ユタ州: 給水SCADAシステム
2010 年、ユタ州北部のわずか数マイルしか離れていない 2 つの町、トレントンとアマルガは、2 つの市営水道システムを相互接続する設計と構築の計画を立てました。相互接続システムにより、トレントンからアマルガへの水の流れが自動的になり、その逆も可能になり、緊急時に 2 つの町で水を共有できるようになります。これを実現するために、両町はローガンの JUB エンジニアと協力し、ローガンのインターマウンテン エンバイロメンタル (IEI) と契約して、監視制御およびデータ収集 (SCADA) システムを導入しました。これにより、各町は水道システムの状態を確認し、必要に応じて相互接続システムを制御できるようになりました。 各町には水源、ポンプタンク、配水システムがそれぞれ別々にあるため、水を簡単に共有できるように接続することが課題でした。Intermountain Environmental......続きを読む

Privacy Policy Update

We've updated our privacy policy.  詳細はこちら

Cookie Consent

Update your cookie preferences.  クッキーの設定を更新する