RETIRED ›
This product is no longer available and has been replaced by: SI-111SS.
SI-111 Infrared Radiometer with Standard Field of View
利用できるサービス

概要

The SI-111, manufactured by Apogee, is a precision infrared radiometer that determines the surface temperature of an object without physical contact. It measures both the subject's surface temperature and the sensor-body temperature. A Campbell Scientific data logger uses these measurements to calculate the correct temperature of the subject.

続きを読む

利点と特徴

  • Compatible with most Campbell Scientific data loggers
  • Measures surface temperature continuously in the field
  • Provides road surface, plant canopy, soil surface, snow surface, and water surface temperature measurements
  • Avoids influencing the temperature, providing more accurate measurements
  • Ideal for providing spatial averages
  • Rugged construction—two temperature probes housed in an aluminum body with a germanium window

イメージ

SI-111
SI-111
SI-111
SI-111 with cap
Field of View (FOV) for the SI-111

詳細

The SI-111 consists of a thermopile, which measures surface temperature, and a thermistor, which measures sensor body temperature. The two temperature sensors are housed in a rugged aluminum body that contains a germanium window.

Both the thermopile and the thermistor output a millivolt signal that most of our data loggers can measure. The data logger uses the Stefan-Boltzman equation to correct for the effect of sensor body temperature on the target temperature. The corrected readings yield an absolute accuracy of ±0.2°C from -10° to +65°C.

Field of View (FOV)

The SI-111 has a 22-degree half-angle field-of-view (FOV). The FOV is reported as the half-angle of the apex of the cone formed by the target (cone base) and the detector (cone apex). The target is a circle from which 98% of the radiation viewed by the detector is being emitted.

Note: Prior to November 2008, the SI-111 was named the IRR-P.

仕様

Input Power 2.5 V excitation (for thermistor)
Response Time < 1 s (to changes in target temperature)
Target Temperature Output Signal 60 μV per °C difference from sensor body
Body Temperature Output Signal 0 to 2500 mV
Optics Germanium lens
Wavelength Range 8 to 14 μm (corresponds to atmospheric window)
Field of View (FOV) 22° half angle
Operating Temperature Range -55° to +80°C
Operating Relative Humidity Range 0 to 100% RH
Cable Description 4.5 m (14.76 ft) twisted, shielded 4-conductor wire with Santoprene casing, ending in pigtails
Absolute Accuracy
  • ±0.2°C (-10° to +65°C)
  • ±0.5°C (-40° to +70°C)
Uniformity
  • ±0.1°C (-10° to +65°C)
  • ±0.3°C (-40° to +70°C)
Repeatability
  • ±0.05°C (-10° to +65°C)
  • ±0.1°C (-40° to +70°C)
Diameter 2.3 cm (0.9 in.)
Length 6 cm (2.4 in.)
Weight 190 g (6.7 oz)

互換性

注意: 以下は代表的な互換性情報を示しています。互換性のある製品や互換性のない製品をすべて網羅したリストではありません。

Data Loggers

製品 互換性 注意
21X (リタイア)
CR10 (リタイア)
CR1000 (リタイア)
CR10X (リタイア)
CR200X (リタイア)
CR206X (リタイア)
CR211X (リタイア)
CR216X (リタイア)
CR23X (リタイア)
CR295X (リタイア)
CR300 (リタイア)
CR3000 (リタイア)
CR310
CR500 (リタイア)
CR5000 (リタイア)
CR510 (リタイア)
CR6
CR800 (リタイア)
CR850 (リタイア)
CR9000 (リタイア)
CR9000X (リタイア)

互換性に関する追加情報

Mounting

The SI-111 is often fastened to a CM200-series crossarm, a tripod or tower mast, or a user-supplied pole using a CM230, CM230XL, or CM220 mount. The CM230 and CM230XL are adjustable inclination mounts that allow the SI-111 to be mounted perpendicular to the target surface when the target surface is on an incline. The CM230XL is similar to the CM230, but the CM230XL places the SI-111 further from the pole or crossarm. The SI-111 may also be attached directly to a user-supplied camera tripod.


よくある質問

SI-111に関するよくある質問の数: 8

すべて展開すべて折りたたむ

  1. There are two accuracy specifications listed for the SI-111:

    • One for when the difference in the target and sensor body temperatures is less than 20°C (more accurate)
    • One for when the difference in the target and sensor body temperatures is greater than 20°C (less accurate)

    Using a radiation shield with the sensor helps keep the sensor body temperature in close approximation to the ambient air temperature. Ultimately, the need to protect the sensor from short-wave radiation is dependent on what is being measured and under what conditions. For example, Campbell Scientific recommends using a radiation shield for canopy measurements.

  2. As a general recommendation, recalibration should be done every two years. 

  3. The window in the Apogee infrared sensor is inset and protected, but it can become partially blocked in three ways:

    1. Spiders can make a nest in the entrance. Campbell Scientific recommends using a cotton swab to apply a spider repellent around the entrance to the aperture. Do not apply the repellent, however, to the sensor window itself.
    2. Calcium deposits can accumulate on the window if irrigation water sprays up on the head. These deposits typically leave a thin white film on the surface, which can be removed with a diluted acid, such as vinegar. Calcium deposits cannot be removed with solvents such as alcohol or acetone.
    3. In windy environments, dust and dirt can be deposited in the aperture. The aperture can be cleaned with deionized water, rubbing alcohol, or in extreme cases, acetone.

    Clean the inner threads and sensor window using a cotton swab dipped in the appropriate solvent. For additional cleaning information, see the Maintenance section of the instruction manual.

  4. The SI-111 has been successfully calibrated with a maximum cable length of 100 m without a loss in accuracy. Ideally, the sensor is calibrated with the overall cable length already configured. Our tests have shown, however, that adding a few meters of cable in the field has a negligible effect on the calibration, provided the measurement device has significantly high input impedance, such as with the CR1000.

  5. The SI-111 can be used to measure a wide variety of surfaces, including water and snow. When measuring objects with low emissivity, however, it is particularly important to apply corrections to the measurement. 

  6. キャリブレーション シートに含まれる情報は、センサごとに異なります。一部のセンサでは、シートにデータロガーをプログラムするために必要な係数が含まれています。その他のセンサでは、キャリブレーション シートは合格/不合格レポートです。

  7. これは、キャリブレーション シートに含まれる情報によって異なります。

    • キャリブレーション シートに係数情報が含まれている場合、Campbell Scientific はコピーを保管し、交換コピーを要求することができます。
    • キャリブレーション シートに係数が含まれていない場合、Campbell Scientific はコピーを保管しません。製造元に連絡して交換用コピーを入手できる場合があります。
  8. IR 放射の損失のため、ほぼすべてのサーモパイル計器には通常、負のオフセットがあります。このオフセットは夜間に最も目立ち、ゼロではなく小さな負の値が読み取られます。この同じオフセットは日中にも存在しますが、太陽信号が大きいため目立ちません。

    もう 1 つの一般的な問題は、計器の水平調整です。サーモパイル計器の水平調整では、コサイン応答が正しくないため、直接ビーム成分にエラーが発生する可能性があります。太陽が地平線に近い場合、角度が非常に浅いため、これらのエラーはより顕著になります。

ケーススタディ

イギリス:炭素隔離の先駆的研究
概要 気候変動との戦いにおいて、大気中の温室効果ガス濃度の上昇という地球規模の課題に対処するための革新的な解決策が生まれています。英国生態学・水文学センター (UKCEH) は、アベリストウィス大学などと提携して、この研究の最前線に立っています。Campbell Scientific社の最先端の渦相関システムを使用して、UKCEH はさまざまな作物による CO2 吸収を監視するプロジェクトを先導しており、主に多用途のススキ (エレファント グラス) に焦点を当てています。 課題 大気中の温室効果ガス濃度の上昇という差し迫った問題に対処するには、その地球温暖化への影響を総合的に理解し、その影響を緩和する必要があります。課題は、エネルギー安全保障と農村経済を維持しながら、大気中の CO2 濃度の削減に積極的に貢献する持続可能な解決策を見つけることです。 解決策 UKCEH は、キャンベル サイエンティフィック社の高度な渦相関システムを導入し、作物による大気中の CO2......続きを読む
中国:フラックス協力
このケーススタディでは、中国科学院清遠森林 CERN 研究所の不均一な地形におけるCO 2 /H 2O微量ガスフラックスを測定する理論と技術を探すためにCPEC310およびAP200システムを統合する方法について説明します。 CPEC310 (閉路渦相関システム) と AP200 (大気プロファイル システム) は、微気象センサー、硝酸塩関連の微量ガス分析装置、土壌表面 CO 2フラックス システムとともに、中国科学院清遠森林 CERN フィールド研究所における森林生態学と管理に関する研究を促進する 3 つの高さ......続きを読む
オンタリオ州: 緑の屋根
問題 — 緑の屋根の性能を最適化する方法 トロント大学のグリーン ルーフ イノベーション テスト ラボ (GRIT ラボ) は、断熱、降雨吸収、美観と環境面での利点を提供する植物床で覆われた屋根であるグリーン ルーフの性能を調査し、最適化するために設立されました。GRIT ラボは、気象観測所と 1.22 m x......続きを読む
コロラド州: ALERT システムからの RWIS データ
ALERT プロトコルを使用するネットワークは、洪水の可能性を示すデータにすぐにアクセスできるように設計されています。ALERT ステーションは通常、時間指定およびイベント ベースで水文データと気象データを取得して送信するように設定されています。多くのユーザーが気づいていないのは、ALERT ステーションの運用に使用される Campbell Scientific データ ロガーには十分な余裕があり、その機能を活用してさまざまなサービスを実行できるということです。 コロラド州ダグラス郡は、デンバーの都市排水洪水制御地区 (UDFCD) と連携して、大規模な ALERT ネットワークを運用し、潜在的な洪水状況を監視します。2008 年に、同郡は次に設置する ALERT......続きを読む
コロンビア:バラの菌類との戦い
バラやその他の花の栽培と輸出は、コロンビアでは一大産業です。約 40 年前、アメリカとコロンビアの政府は、バナナ、コーヒー、パーム油など、価格が大きく変動する作物に代わる現実的な農産物を農家に提供できる農産物輸出として、花の栽培を奨励し始めました。20 年後、農家にコカの生産をやめるよう促すインセンティブがさらに追加されました。現在、コロンビアは世界の切り花の約 11% を生産し、アメリカ市場の半分以上を占めています。業界の成長に伴い、この業界がコロンビアの人々と天然資源に及ぼす大きな影響が精査されるようになりました。水の消費と農薬の使用は、業界が規制されていなかった初期の段階ではほとんど問題になりませんでした。しかし、労働力が近代化されるにつれて、安全な労働条件と環境管理を求める声が高まっています。栽培者は、農薬の使用にもっと注意を払うよう努めるとともに、労働者と流域への危険を少なくして病気を根絶する方法を学ぶために、病気の研究に多大な労力を費やしています。そうした取り組みの 1 つとして、ホルヘ・タデオ・ロサノ大学の農工業研究センターは、バラのべと病を引き起こす菌類であるperonospora sparsa の発生を促進する条件の変数についての研究を開始しました。研究の準備として、研究者らは、バラが栽培されている温室の状態を監視するための測定ステーションを 2 つ構築しました。ソーラー パネルで電力を供給されるこれらのステーションには、植物の間のさまざまな場所に配置された複数の Decagon LWS......続きを読む

下記の製品は置き換えられました

Privacy Policy Update

We've updated our privacy policy.  詳細はこちら

Cookie Consent

Update your cookie preferences.  クッキーの設定を更新する