RETIRED ›
This product is no longer available and has been replaced by: SDM-CD16ACA.
SDM-CD16AC 16-Channel AC/DC Relay Controller
利用できるサービス
修理 対応
キャリブレーション 対応
フリーサポート 対応

概要

With an SDM-CD16AC, your Campbell Scientific data logger can automatically activate external ac or dc devices such as motors, pumps, heaters, valves, and fans. This ac/dc relay controller has 16 ports for connecting your ac or dc devices. Each port can be controlled automatically by the data logger’s program or controlled manually with an override toggle switch.

続きを読む

利点と特徴

  • Allows the data logger to automatically turn devices on or off when a threshold (for example, temperature or water depth) has been reached
  • Addresses up to 16 SDM-CD16ACs, allowing up to 256 ports to be controlled by one data logger
  • Includes LEDs that indicate when a port is active
  • Provides a manual override for each port
  • UL/CUL approved product

イメージ

詳細

The SDM-CD16AC has a toggle switch that provides three positions: ON and OFF for manual override, and AUTO for data logger control.

  • In the ON position, the common (COM) and normally open (NO) contacts are closed.
  • In the OFF position, the normally open contact is open.
  • In the AUTO position, the state of the relay is controlled by the SDM command issued through the data logger’s control ports or SDM terminal.

SDM Operation

The SDM-CD16AC is a synchronously addressed data logger peripheral. Data logger control ports 1, 2, and 3 are used to address the SDM-CD16AC, then clock out the desired state of each of the 16 control ports. Up to 16 SDM-CD16ACs may be addressed, making it possible to control a maximum of 256 ports from the first three data logger control ports.

仕様

Function Allows a data logger to automatically activate external ac or dc devices such as motors, pumps, heaters, valves, and fans.
Number of Channels 16
Operating Temperature -40° to +55°C
Humidity Non-condensing
Contact Operation Single pole double throw (break before make)
Contact Material Gold-clad silver
Coil Voltage 11 to 18 Vdc
Coil Resistance 360 Ω ±10%
Expected Life (contact closures) Mechanical 107
Actuation/Release Time ~4 ms
Toggle Switch
  • ON/OFF manual override
  • AUTO for data logger control
Operating Voltage 12 Vdc nominal (11 to 18 Vdc)
Standards Underwriters Laboratories (UL) listed product (E162021)
Dimensions 24.6 x 5.1 x 8.6 cm (9.7. x 2.0 x 3.4 in.)
Weight 0.8 kg (1.8 lb)

Individual Contact Ratings

Normally Open Rating
  • 5 A (@ 30 Vdc)
  • 5 A (@ 125 Vac)
  • 5 A (@ 250 Vac)
Normally Closed Rating
  • 1 A (@ 30 Vdc)
  • 3 A (@ 125 Vac)
  • 2 A (@ 250 Vac)

Current Drain @ 12 Vdc

Quiescent 6 mA
Per Active LED 45 mA (switch on or auto active)

互換性

注意: 以下は代表的な互換性情報を示しています。互換性のある製品や互換性のない製品をすべて網羅したリストではありません。

Data Loggers

製品 互換性 注意
21X (リタイア)
CR10 (リタイア)
CR1000 (リタイア)
CR1000X (リタイア)
CR10X (リタイア)
CR200X (リタイア)
CR206X (リタイア)
CR211X (リタイア)
CR216X (リタイア)
CR23X (リタイア)
CR295X (リタイア)
CR300 (リタイア)
CR3000 (リタイア)
CR310
CR350
CR500 (リタイア)
CR5000 (リタイア)
CR510 (リタイア)
CR6
CR800 (リタイア)
CR850 (リタイア)
CR9000 (リタイア) Although the CR9000 is compatible, the SDM-CD16AC does not support its fastest communication rates and therefore is not practical for most of its applications.
CR9000X (リタイア) Although the CR9000X is compatible, the SDM-CD16AC does not support its fastest communication rates and therefore is not practical for most of its applications.

Mounting Equipment

製品 互換性 注意
ENC10/12
ENC10/12R
ENC12/14
ENC14/16
ENC16/18
ENC24/30
ENC24/30S

Distributed Data Acquisition

製品 互換性 注意
Granite 10
Granite 6
Granite 9

互換性に関する追加情報

Data Logger Considerations

Up to 16 SDMs can be connected to our data loggers. To communicate with connected SDM devices, the CR3000 and CR5000 use the SDM-C1, SDM-C2, and SDM-C3 ports. The other data loggers use ports labeled C1, C2, and C3. The 21X also requires channel 1H.

Programming

The SDMCD16AC Instruction controls SDM-CD16AC operation in CRBasic. Edlog Instruction 29 controls SDM-CD16AC operation in the CR7, and Edlog Instruction 104 controls SDM-CD16AC operation in the CR10(X), CR23X, and 21X data loggers.

Power Considerations

The data logger's rechargeable power supply, connected to our newer 1.2 A wall charger, is sufficient for powering the SDM-CD16AC. The SDM-CD16AC's LEDs consume 45 mA each when active. If all 16 LEDs are active at once, a current drain of over 720 mA should be expected. If more than one SDM-CD16AC will be used, a deep-discharge external battery may be necessary. This external battery should share a common grounding point with the data logger's ground.

Campbell Scientific does not recommended using the data logger’s alkaline batteries to power the SDM-CD16AC for long-term applications.

Enclosure Considerations

The SDM-CD16AC requires a desiccated, non-condensing environment; a Campbell Scientific enclosure is recommended. Grommets and screws are provided to attach the flanges/bracket to the backplate of our enclosures.

ダウンロード

SDM-CD16AC Program Examples v.1 (3 KB) 11-04-2022

There are three example programs for the CDM-CD16AC. The first program demonstrates using two SDM-CD16AC modules to control pumps and heaters based on water level and temperature thresholds. The remaining two programs are designed to control the temperature in five greenhouses. The temperature will be maintained between 23 and 28 °C in each greenhouse. In each greenhouse, the SDM-CS16AC controls a heating unit, a refrigerating unit, and an air-mixing fan according to these conditions.  

Heating unit: Activate when temperature < 23.5 °C. Deactivate when temperature > 25.5 °C

Cooling unit: Activate when temperature > 27.5 °C. Deactivate when temperature < 24.5 °C

Mixing fan: Activate whenever the heating or cooling units are activated. Activate for 5 minutes out of every 15 minutes.

The difference between program 2 and program 3 is the method used to control outputs. Program 2 uses an array to set the SDM-CD16AC outputs. Program 3 uses a Long integer, with each bit in the variable controlling one of the outputs.

よくある質問

SDM-CD16ACに関するよくある質問の数: 1

  1. CR800 および CR850 では、次のリレー デバイスを使用できます。

    • 7321
    • A6REL-12*
    • A21REL-12
    • LR4
    • SDM-CD8S
    • SDM-CD16AC
    • SDM-CD16ACA
    • SDM-CD16S

    CR800 と CR850 は、さまざまなサードパーティ製リレー デバイスでも使用できます。

    *CR800 と CR850 にはデジタル ポートが 4 つしかないため、A6REL-12 の 6 つのリレーすべてを切り替えることはできません。

ケーススタディ

ニューメキシコ州: SCADA システム
2015 年 4 月、サンディア国立研究所 (SNL) は、モントローズ大気品質サービス (MAQS) と契約し、プロセス廃水処理施設の既存の SCADA システムをアップグレードしました。このシステムにより、所有者はアルバカーキ市が要求する排出許可の問題に準拠しやすくなります。 SNL は、処理水を捕集して市の下水道に排出するために保管する水処理およびサンプリング施設を運営しています。保管タンクが満杯になると、水のサンプルが採取され、研究所での分析に送られます。水タンクは、排出許可証に指定された品質基準を満たしている場合、市の水処理システムへの排出対象として選択されます。 オリジナルの SCADA システムは 1994 年に導入されました。このシステムは次の機能を提供しました。......続きを読む
Flemish Coast: Pile Monitoring
Cofely Fabricom NV/SA (GDFSuez) has utilized Campbell Scientific equipment on numerous projects in both the......続きを読む
ニュージャージー州:マス養殖場
マス養殖施設に清潔で冷たい水を流すことは、マス養殖の成功に不可欠です。マスのような生きた魚は、1 日 24 時間、週 7 日間、細心の注意を払って管理する必要があり、ミスはほとんど許されません。Campbellの機器は、ペクエスト トラウト孵化場での水の管理を正確かつ確実にするのに役立っています。 施設では、水の流れを調整および制御するために、旧式の配線とタッチトーン テレメトリに依存していました。古いシステムでは、6 つの井戸から水がエアレーション装置を通り、最終的に魚のレースウェイに流れ込むときに、ポンプ、ゲート、バルブを制御する必要がありました。古い機器の修理が難しくなり、新しいテクノロジーが成熟するにつれて、Pequest の管理者は、水産養殖機器に関する世界的な経験を持つ Campbell Scientific に連絡しました。 新しい計器により、監視および制御システムにいくつかの大きな改善がもたらされました。対処する必要があった問題の 1 つは、井戸、ポンプ、および制御センター間の距離でした。当社のエンジニアは、スペクトラム拡散無線技術を実装して孵化場システムのすべてのコンポーネントを接続し、地上回線の問題と保守コストを回避しました。 各拠点の無線に接続されたデータロガーは、ポンプ、流量計、警報器、統合気象観測所を監視および制御します。バックアップとデータおよび制御機能へのより広範なアクセスのために、2......続きを読む
オーストラリア: 二酸化炭素と気候変動の影響の調査
オーストラリアのタウンズビルに、二酸化炭素濃度の上昇と気候変動が熱帯サバンナに影響を与えるための実験施設 (OzFace) が設置されました。世界中には他にも自由大気二酸化炭素濃縮 (FACE) システムがいくつかありますが、OzFace システムはオーストラリア初であり、熱帯サバンナで実施される世界初のシステムです。Campbell Scientific Australia が設計および構築した OzFace システムは、Queensland Nickel Pty主な目的は、自然条件下で、制御された高レベルの CO2 が生態系に与える影響を調査することです。これは単純に聞こえますが、風速と風向が変化する状況で......続きを読む
カリフォルニア州:循環型養殖施設における水質監視
1996 年 8 月、Stolt Sea Farm ( www.stoltseafarm.com ) は、カリフォルニア州エルク グローブの再循環施設に Campbell Scientific の監視および制御システムを導入しました。このシステムは、溶存酸素レベル、水温、および全溶存ガスを監視し、それらの測定値に基づいて、酸素制御用のソレノイド値を自動的に制御します。Campbell システムには、CR10X、AM416......続きを読む
ミシシッピ州: 溶存酸素の監視と制御
養殖業の成功は、最終的には溶存酸素の濃度にかかっています。DO の測定は、水質の最も重要なパラメータです。また、多くの養殖業者が一晩に何度も池のチェックを強いられる理由でもあります。綿密で継続的な監視がなければ、魚のストレスや死亡を防ぐのに役立つ必要な警告が検知されず、生産サイクル全体が失敗に終わる可能性があります。 そのため、1996 年 5 月、リーバイ・リーと息子のジェフはCampbell Scientificに助けを求めました。ミシシッピ州メーコンにある複数の池を持つナマズ養殖場で使用するために、CR10X 計測および制御システムを購入しました。一晩に複数の池をチェックすることが、個人および養殖業務全体に負担をかけることを十分に理解していたリー夫妻は、今では池のチェックと制御を 1 か所で済ませることができます。それは、個人のコンピューターです。また、いずれかの池で溶存酸素が極端に低下した場合は、無線制御のアラームが同じコンピューターを通じてリー夫妻に警告を発し、貴重な時間と睡眠時間を節約します。また、情報に基づいた迅速な修復措置を取ることもできます。  初期設置は 2 つのステーションで構成され、どちらも測定と制御の決定のための CR10X データロガー、エアレーターへの AC 電源を制御するための......続きを読む

下記の製品は置き換えられました