利用できるサービス | |
---|---|
修理 | 対応 |
フリーサポート | 対応 |
The SR50A Sonic Distance Sensor provides a non-contact method for determining snow depth. It determines depth by emitting an ultrasonic pulse and then measuring the elapsed time between the emission and return of the pulse. An air temperature measurement is required to correct for variations of the speed of sound in air.
Note: Campbell Scientific recommends model SR50A-EE-L for operation in extreme environmental conditions where corrosion is a concern (such as coastal regions).
続きを読むThe SR50A was designed to meet the stringent requirements of measuring snow depth, and it uses a multiple echo processing algorithm to help ensure measurement reliability.
SDI-12, RS-232, and RS-485 output options are available for measuring the SR50A. Campbell Scientific’s MD485 interface can be used to connect one or more SR50A sensors in RS-485 mode to an RS-232 device. This can be useful for sensors that require lead lengths that exceed the limits of either RS-232 or SDI-12 communications.
The SR50A replaced the SR50 in March 2007. The newer SR50A is smaller and has different output options than its predecessor. The SR50AH is available with a heater option for locations where rime ice is a problem.
Measurement Description | Snow depth |
Measurement Time | < 1.0 s |
Measurement Range | 0.5 to 10 m (1.6 to 32.8 ft) |
Output Options | SDI-12 version 1.3, RS-232, RS-485 (output options selected by configuring internal jumpers) |
Baud Rates | 1200 to 38400 bps (RS-232, RS-485 modes) |
Power Requirements | 9 to 18 Vdc (typically powered by data logger’s 12 Vdc power supply) |
Beam Acceptance | ~30° |
Resolution | 0.25 mm (0.01 in.) |
Accuracy | ±1 cm (0.4 in.) or 0.4% of distance to target (whichever is greatest). Requires external temperature compensation. |
Operating Temperature Range | -45° to +50°C |
Temperature Accuracy |
|
Compliance | CE Compliant |
Length | 10.1 cm (4.0 in.) |
Diameter | 7.5 cm (3 in.) |
Cable Weight | 250 g (8.2 oz) for a 4.57-m (15-ft) cable |
Weight |
|
Maximum Cable Length |
|
-NOTE- | Cable lengths greater than 60 m require a heavier gage wire if the power supply drops below 11 Vdc. |
SDI-12 | 60 m (200 ft) |
RS-232 |
60 m (200 ft) Baud rates ≤ 9600 bps |
RS-485 | 300 m (984 ft) |
Power Consumption |
|
Active | 250 mA (typical) |
Quiescent SDI-12 Mode | < 1.0 mA |
Quiescent RS-232/RS-485 Modes |
|
注意: 以下は代表的な互換性情報を示しています。互換性のある製品や互換性のない製品をすべて網羅したリストではありません。
製品 | 互換性 | 注意 |
---|---|---|
21X (リタイア) | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR10 (リタイア) | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR1000 (リタイア) | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR1000X (リタイア) | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR10X (リタイア) | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR200X (リタイア) | SDI-12 | |
CR206X (リタイア) | SDI-12 | |
CR211X (リタイア) | SDI-12 | |
CR216X (リタイア) | SDI-12 | |
CR23X (リタイア) | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR295X (リタイア) | SDI-12 | |
CR300 (リタイア) | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR3000 (リタイア) | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR310 | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR350 | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR500 (リタイア) | SDI-12 | |
CR5000 (リタイア) | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR510 (リタイア) | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR6 | SDI-12, RS-232, and RS-485 | |
CR800 (リタイア) | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR850 (リタイア) | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR9000 (リタイア) | ||
CR9000X (リタイア) | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. |
製品 | 互換性 | 注意 |
---|---|---|
Granite 6 | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. |
CR6 and CR1000X programs that directly read each type of SR50A output (SDI-12, RS-232, RS-485), and a CR1000 program that reads the RS-485 output using an MD485 Multidrop interface. A 107 sensor provides the temperature measurement needed for temperature compensation. The programs use the data filtering method described in the manual.
SR50A-Lに関するよくある質問の数: 15
すべて展開すべて折りたたむ
Yes. This sensor has an SDI-12 output.
No. The maximum cable length is approximately 800 ft.
The sensitivity can be adjusted slightly at the factory, but it cannot be recalibrated. Typically, the transducing diaphragm needs to be replaced periodically to maintain calibration. This can be done by the user or at the factory.
Position the sensor at a height that is between 0.5 m and 10 m above the target.
The potential error is roughly ±0.4% of distance for a ±25° Celsius variation away from 0° Celsius.
Because the speed of sound changes with temperature, Campbell Scientific recommends using the SR50A-L in tandem with a temperature sensor for the most accurate measurements.
No. This causes echoes and reflections that confuse the sensor.
Approximately 800 feet. This is a function of the limitations of the SDI-12 signal.